Finding | |
|---|---|
| Title | Failure to Comply With ASME Code Requirements for Repair on Code Class 1 Component |
| Description | A finding of very-low safety significance (Green) and associated NCV of 10 CFR 50.55a(g)(4) was identified by the inspectors for the licensees failure to maintain the American Society of Mechanical Engineers (ASME) Code Class 1 component in accordance with ASME Code Section XI requirements. Specifically, the licensee failed to measure and document the method of measuring the cavity created after removal of indications on the reactor water clean-up line prior to return to service. The inspectors determined that the licensees failure to maintain the ASME Code Class 1 component in accordance with ASME Code Section XI requirements was a performance deficiency. This performance deficiency was found to be more-than-minor, and a finding, because the performance deficiency, if left uncorrected could become a more significant safety concern. Specifically, absent NRC identification, the licensee would not have questioned the potential challenge to component functionality since the cavity measurements were not performed. This condition could potentially lead to the failure of the reactor water clean-up bottom head drain, which in turn, could lead to a potential loss of reactor coolant. The inspectors reviewed the finding using Attachment 0609.04, Initial Characterization of Findings, Table 3 SDP Appendix Router. The inspectors answered No to the question in Section A of Table 3 and therefore the finding was evaluated using the SDP in accordance with IMC 0609, The Significance Determination Process (SDP) for At-Power Operations, Appendix A, Exhibit 1, Initiating Events Screening Questions. The inspectors answered No to the questions in Exhibit 1 and determined this finding to have a very-low safety significance (Green). The inspectors determined that this finding has a cross-cutting aspect in the area of Human Performance, Design Margin, for the licensees failure to maintain equipment within design margins. Specifically, the licensee staff failed to ensure that metal removal performed on an ASME Code Class 1 component did not result in a condition where the minimum design wall thickness of the component was compromised, and therefore, failed to ensure design margin was maintained. |
| Site: | Perry |
|---|---|
| Report | IR 05000440/2016007 Section 4OA2 |
| Date counted | Jun 30, 2016 (2016Q2) |
| Type: | NCV: Green |
| cornerstone | Initiating Events |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | A Shaikh J Hafeez M Domke R Daley |
| Violation of: | 10 CFR 50.55a |
| CCA | H.6, Design Margins |
| INPO aspect | WP.2 |
| ' | |
Finding - Perry - IR 05000440/2016007 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Perry) @ 2016Q2
Self-Identified List (Perry)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||