05000440/FIN-2015008-01
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Ensure that Systems, Structures, and Components Necessary to Achieve and Maintain Hot Shutdown Conditions were Free of Fire Damage without Repair Actions |
| Description | The inspectors identified a finding of very low safety significance (Green), and associated NCV of license condition 2.C(6) for the licensees failure to ensure that systems, structures, and components necessary to achieve and maintain hot shutdown conditions were free of fire damage. Specifically, the licensee did not ensure that circuits associated with the emergency closed cooling (ECC) heat exchanger A temperature control valve 1P42-F665A were free of fire damage for a fire in the control room and instead relied on lifting leads and replacing fuses to take manual control of the valve. The licensee entered the issue into their CAP, and credited the existing repair activities in the procedure. The inspectors determined that the performance deficiency was more than minor because a fire in the control room could result in the licensee losing the ability to remotely control the ECC heat exchanger A temperature control valve and needing to take manual control of the valve. The finding was of very low safety significance because it did not affect the ability to reach and maintain a stable plant condition within the first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> of a fire event. The finding did not have a cross-cutting aspect associated with it because it was not reflective of current performance. |
| Site: | Perry |
|---|---|
| Report | IR 05000440/2015008 Section 1R05 |
| Date counted | Dec 31, 2015 (2015Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.05 |
| Inspectors (proximate) | A Dahbur D Szwarc G Hausman R Daley R Winter |
| Violation of: | License Condition - Fire Protection License Condition |
| INPO aspect | |
| ' | |