05000397/FIN-2015003-02
Finding | |
|---|---|
| Title | Non-Conservative Shutdown Criteria in Earthquake Abnormal Procedure |
| Description | The inspectors identified a non-cited violation of Technical Specification 5.4.1.a, Procedures, for the failure to maintain an adequate abnormal procedure for earthquakes. Specifically, the licensee failed to establish appropriate shutdown criteria for earthquakes that exhibit ground motion exceeding the operating basis earthquake (OBE). The licensees shutdown criteria would allow for continued operations if ground motion at a single frequency exceeded the design response spectrum. In response to this issue, the licensee initiated corrective actions to change the stations earthquake abnormal procedure to provide shutdown criteria consistent with the original licensing basis of the facility. The licensee entered this issue into their corrective action program as Action Request 336875. The performance deficiency was more than minor because it affected the procedura
adequacy attribute of the Mitigating Systems Cornerstone objective and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the performance deficiency resulted in shutdown criteria that would allow for continued operations following events where ground motion at a single frequency exceeded the desig response spectra. NRC regulations require a plant shutdown since systems necessary for continued operation without undue risk to the health and safety of the public are not designed to remain functional, in all cases, following an OBE. The inspector performed the initial significance determination using NRC Inspection Manual Chapter 0609, Appendix A, Exhibit 2, Mitigating Systems Screening Questions. The inspectors determined that the finding was of very low safety significance because (1) the finding was not a deficiency affecting the design or qualification of a mitigating system; (2) the finding did not represent a loss of system and/or function; (3) the finding did not represent an actual loss of function of a single train for greater than its technical specification allowed outage time; and (4) the finding does not represent an actual loss of function of one or more non-technica specification trains of equipment designated as high safety-significant in accordance with the licensees maintenance rule program for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Additionally, the finding did not involve the loss or degradation of equipment or function specifically designed to mitigate a seismic, flooding, or severe weather initiating event. The finding does not have a cross-cutting aspect since the procedure error is associated with a 1996 change to the licensing basis and therefore not reflective of current licensee performance. |
| Site: | Columbia |
|---|---|
| Report | IR 05000397/2015003 Section 1R04 |
| Date counted | Sep 30, 2015 (2015Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.04 |
| Inspectors (proximate) | C Stott D Bradley J Groom J O'Donnell L Carson M Phalen N Greene R Smith |
| Violation of: | Technical Specification - Procedures Technical Specification |
| INPO aspect | |
| ' | |