Finding | |
|---|---|
| Title | Failure to Translate Design Basis into Component Classification Evaluation Records |
| Description | The team identified a Green, non-cited violation of 10 CFR Part 50, Appendix B, Criterion III, Design Control, for the licensees failure to translate the design basis into specifications. Specifically, the team identified five instances where the licensee failed to translate the design basis into specifications in the form of component classification evaluation records. Plant operators use these records to establish the current licensing basis of the facility when performing operability determinations. The licensee initiated Action Request ARs 323666, 324082, 324130, 324135 and 324144, to address the individual examples of inaccurate component classification records and AR 324160324160to address process deficiencies related to the use of these records. The licensees failure to translate station design requirements into specifications was a performance deficiency. The performance deficiency is more than minor because it affects the design control attribute of the Mitigating Systems cornerstone and adversely affects the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, this performance deficiency resulted in inaccurate design basis documents being used by plant operators to make operability decisions. The finding is of very low safety significance (Green) because the finding was not a deficiency affecting the design or qualification of a mitigating system; the finding did not represent a loss of system and/or function; the finding did not represent an actual loss of function of a single train for greater than its technical specification allowed outage time; and the finding does not represent an actual loss of function of one or more non-technical specification trains of equipment designated as high safety-significant in accordance with the licensees maintenance rule program for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. This finding has a cross-cutting aspect in the area of problem identification and resolution, resolution, in that the licensee failed to take timely action to address inadequate design records [P.3]. |
| Site: | Columbia |
|---|---|
| Report | IR 05000397/2015007 Section 4OA2 |
| Date counted | Mar 31, 2015 (2015Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | A Allen D Proulx H Freeman J Groom T Hartman |
| Violation of: | 10 CFR 50 Appendix B Criterion III, Design Control Technical Specification |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |