Finding | |
---|---|
Title | Failure to Establish Appropriate Work Instructions for 480-Volt Motor Control Center Starters |
Description | The inspectors reviewed a self-revealing non-cited violation of Technical Specification 5.4.1.a, Procedures, for the licensees failure to provide adequate work instructions for performing maintenance on 480-volt motor control center starter PRA-42- 8AA4B. Consequently, the starters thermal overload mounting screws were over-torqued resulting in an unexpected loss of pump house recirculation air fan PRA-FN-1B. The licensee repaired the improperly torqued thermal overload mounting screws and initiated AR 321368 to address the inadequate work instructions that resulted in the unexpected trip of the thermal overloads for fan PRA-FN-1B. The performance deficiency was more than minor because it affected the equipment performance attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. The inspectors performed the initial significance determination using NRC Inspection Manual Chapter 0609, Appendix A, Exhibit 2, Mitigating Systems Screening Questions. The inspectors determined that the finding was of very low safety significance because (1) the finding was not a deficiency affecting the design or qualification of a mitigating system; (2) the finding did not represent a loss of system and/or function; (3) the finding did not represent an actual loss of function of a single train for greater than its technical specification allowed outage time; and (4) the finding does not represent an actual loss of function of one or more nontechnical specification trains of equipment designated as high safety-significant in accordance with the licensees maintenance rule program for greater than 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. This finding had a cross-cutting aspect in the area of human performance, resources, in that the licensee failed to ensure that appropriate insights from the vendor manual were utilized when preparing work documents [H.1]. |
Site: | Columbia |
---|---|
Report | IR 05000397/2015001 Section 1R19 |
Date counted | Mar 31, 2015 (2015Q1) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71111.19 |
Inspectors (proximate) | D Bradley J Groom N Taylor P Elkmann S Makor W Walker |
Violation of: | Technical Specification - Procedures Technical Specification |
CCA | H.1, Resources |
INPO aspect | LA.1 |
' | |
Finding - Columbia - IR 05000397/2015001 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Columbia) @ 2015Q1
Self-Identified List (Columbia)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||