| Title | Risk Management Actions Not Implemented |
| Description | The inspectors identified a Green NCV of Title 10 Code of Federal Regulations (CFR) 50.65(a)(4) due to multiple examples of not assessing and managing the increase in risk from online maintenance activities. Specifically, on November 12, 2014, a risk assessment did not identify a Yellow online risk condition during a residual heat removal system (RHR) outage. Additionally, the inspectors identified multiple examples where PPL did not implement the procedural requirements of OI-013-002, Fire Risk Management, NDAP-QA-1902, Integrated Risk Management, and NDAP-QA-0340, Protected Equipment Program such that adequate risk mitigation actions were performed. Immediate corrective actions were taken and PPL documented the issues in condition report (CR) 2014-35235 and 2014-35270. The inspectors determined the performance deficiency (PD) was more than minor because it adversely impacted the protection against external factors attribute of the Mitigating Systems cornerstone objective to ensure the capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). The inspectors evaluated the finding using IMC 0612 Appendix K, Maintenance Risk Assessment and Risk Management SDP. The inspectors and the Region I Senior Risk Analyst (SRA) used Appendix K, Flowchart 2, Assessment of Risk Management Actions (RMAs), and determined that not implementing the appropriate RMAs was of very low safety significance (Green). The basis for this determination was that the short duration of the actual planned maintenance activities (62 hours7.175926e-4 days <br />0.0172 hours <br />1.025132e-4 weeks <br />2.3591e-5 months <br /> and 40.5 hours5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br />) associated with the RHR Train B unavailability results in a mid E-9 calculated incremental core damage probability (ICDP), using the Susquehanna Unit 2 standardized plant analysis risk (SPAR) Model, Revision 8.21, and Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) 8. In accordance with Appendix K guidance, doubling the estimated ICDP value to reflect not implementing RMAs is a reasonable approximation of the increased risk. The resultant low E-8 ICDP deficit remains below the ICDP E-6 deficit Green-White threshold and screens this PD to Green. The finding was determined to have a cross-cutting aspect in the area of Human Performance, Work Management, in that, PPL did not control and execute activities, consistent with nuclear safety, by managing risk commensurate to the work and the need for coordination with different groups or job activities. Specifically, PPL did not recognize an elevated risk category and incorporate all RMAs into its work activities [H.5]. |
| Site: | Susquehanna |
|---|---|
| Report | IR 05000387/2014005 Section 1R13 |
| Date counted | Dec 31, 2014 (2014Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.13 |
| Inspectors (proximate) | D Lawyer F Arner F Bower H Gray J Brand J Furia J Grieves J Heinly J Nicholson M Patel O Masnyk-Bailey S Pindale T Daun C Graves |
| Violation of: | 10 CFR 50.65(a)(4) 10 CFR 50.65 |
| CCA | H.5, Work Management |
| INPO aspect | WP.1 |
| ' | |