05000361/FIN-2011005-04
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Licensee-Identified Violation |
| Description | Title 10 CFR 20.1802 states, The licensee shall control and maintain constant surveillance of licensed material that is in a controlled or unrestricted area and that is not in storage. On September 21, 2011, after the completion of the daily performance test of the whole body counter using a mixed gamma source, the check source was not returned to the locked storage location. Since the material was left in an uncontrolled location outside of the Restricted Area there were no barriers to prevent a member of the public from coming into contact with the source. The inspectors determined this finding to be of very low safety significance because the potential dose impact to a member of the public was less than 5 mrem. This issue was documented in the licensees corrective action program as Nuclear Notification NN 201657977. |
| Site: | San Onofre |
|---|---|
| Report | IR 05000361/2011005 Section 4OA7 |
| Date counted | Dec 31, 2011 (2011Q4) |
| Type: | NCV: Green |
| cornerstone | Pr Safety |
| Identified by: | Licensee-identified |
| Inspection Procedure: | |
| Inspectors (proximate) | C Alldredge R Lantz P Elkmann D Stearns L Carson J Reynoso G Warnick C Osterholtz M Young |
| INPO aspect | |
| ' | |
Finding - San Onofre - IR 05000361/2011005 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (San Onofre) @ 2011Q4
Self-Identified List (San Onofre)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||