| Description | The team identified a non-cited violation (NCV) of 10 CFR 50.65, Requirements for Monitoring the Effectiveness of Maintenance at Nuclear Power Plants, for the licensees failure to perform condition monitoring or otherwise implement an appropriate preventive maintenance program for the 2C Diesel Generator (DG) A and B room exhaust fan louvers. The licensee entered this issue into their corrective action program (CAP) as condition reports (CRs) 351580, 349883, and 355130. The failure to perform condition monitoring or otherwise implement an appropriate preventive maintenance program for the 2C DG A and B exhaust fan louvers was a performance deficiency. This performance deficiency was more than minor because it was associated with equipment performance attribute of the mitigating systems cornerstone and adversely affected the cornerstone objective to ensure the availability, reliability and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, the failure to perform condition monitoring or otherwise implement an appropriate preventive maintenance program for the 2C DG A and B room exhaust fan louvers challenged the assurance that these components would remain capable of performing their intended functions. In accordance with NRC IMC 0609.04, Initial Screening and Characterization of Findings, the team used the mitigating systems column to perform a Phase 1 SDP screening and determined the finding to be of very low safety significance (Green) because it was not a design issue resulting in loss of function, did not represent an actual loss of a system safety function, did not result in exceeding a TS allowed outage time, and did not affect external event mitigation. Because the licensee had initiated CRs in 2008 and 2009 for the 2C DG room exhaust louvers, and repairs were not made in a timely manner to address the issue, this finding was assigned a cross-cutting aspect in the corrective action program component of the problem identification and resolution area. |
| Site: | Farley |
|---|---|
| Report | IR 05000348/2011010 Section 1R21 |
| Date counted | Dec 31, 2011 (2011Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | D Jones M Shlyamberg S Sandal R Nease J Eargle P Wagner |
| CCA | P.3, Resolution |
| INPO aspect | PI.3 |
| ' | |
Finding - Farley - IR 05000348/2011010 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Farley) @ 2011Q4
Self-Identified List (Farley)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||