Finding | |
---|---|
Title | Nonconforming Materials Used in EDG Air Coolant Piping System |
Description | A finding of very low safety significance with an associated Non-Cited Violation of 10 CFR 50, Appendix B, Criterion XV, Nonconforming Materials, Parts, or Components, was self-revealed on August 9, 2013, when operators had to manually shut down emergency diesel generator (EDG) 14 due to high air coolant system inlet temperature during a 24-hour surveillance test run. The high temperature condition occurred due to the licensee?s failure to adequately control the installation of the EDG 14 air coolant system control air pipe fitting between the relief valve and pressure regulator to prevent the use of materials that did not conform to design requirements. The licensee completed repairs to the EDG 14 air coolant system and returned the EDG to an operable status. The issue was entered into the licensee?s corrective action program for evaluation and additional corrective actions. The finding was of more than minor safety significance since it was associated with the Design Control attribute and adversely affected the Mitigating Systems Cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). Specifically, the use of nonconforming materials led to failure of the EDG 14 air coolant system control air pipe fitting, which rendered the EDG inoperable. Although the finding involved an actual loss of function of a single train for greater than its Technical Specification allowed outage time, it was determined to be of very low safety significance during a detailed quantitative Significance Determination Process review since the delta core damage frequency was determined to be less than 1E-7/year using the NRC Standardized Plant Analysis Risk model. The inspectors concluded that because the nonconforming control air pipe fitting was installed in the EDG 14 air coolant system in 1988 and the most recent missed opportunity to correct the problem occurred in 2005 or 2006, this issue would not be reflective of current licensee performance and no cross-cutting aspect was identified. |
Site: | Fermi ![]() |
---|---|
Report | IR 05000341/2013005 Section 4OA2 |
Date counted | Dec 31, 2013 (2013Q4) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | M Jones M Kunowski N Adorno P Smagacz R Morris B Kemker B Palagi C Zoia J Laughlin J Nance K Carrington M Bielby |
Violation of: | 10 CFR 50 Appendix B Criterion XV Technical Specification |
INPO aspect | |
' | |
Finding - Fermi - IR 05000341/2013005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Fermi) @ 2013Q4
Self-Identified List (Fermi)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||