05000341/FIN-2012003-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Energizing Bus 65E with Ground Truck Installed and Subsequent Loss of Shutdown Cooling |
| Description | A self-revealed Green finding and associated NCV of 10 CFR 50 Appendix B,Section V, Instructions, Procedures, and Drawings, for failure to follow procedures when the licensee energized a safety-related electrical bus with a ground truck installed in bus 65E breaker position E4. This resulted in the loss of the safety-related bus and a temporary loss of shutdown cooling. The licensee failed to comply with sequence step 61 of Safety Tagging Record 2012-001122, which had connected a ground truck in bus 65E position E4 and installed a red danger tag. The Operations Conduct Manual, Chapter 12 (MOP12), 3.6.2 specifies that red tagged equipment is not to be operated. The licensee entered this item into their corrective action program as CARD 12-23118. The inspectors determined this finding was more than minor because it was associated with the configuration control attribute of the Mitigating Systems Cornerstone and impacted the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences (i.e., core damage). This finding was determined to be of very low safety significance because, following IMC 0609, Appendix G, Attachment 1, Shutdown Operations Significance Determination Process Phase 1 Operational Checklist for both PWRs and BWRs, concluded the finding did not require quantitative assessment. Therefore, the finding was determined to be of very low safety significance. This finding has a cross-cutting aspect in the area of Human Performance, Work Practices, supervisory and management oversight aspect because the licensee failed to appropriately oversee the proper clearance of Safety Tagging Record 2012-001122 |
| Site: | Fermi |
|---|---|
| Report | IR 05000341/2012003 Section 4OA3 |
| Date counted | Jun 30, 2012 (2012Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Self-revealing |
| Inspection Procedure: | IP 71153 |
| Inspectors (proximate) | J Cassidy D Jones R Morris A Wilson R Jones J Cameron P Smagacz T Briley J Steffes S Bell |
| CCA | H.2, Field Presence |
| INPO aspect | LA.2 |
| ' | |
Finding - Fermi - IR 05000341/2012003 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Fermi) @ 2012Q2
Self-Identified List (Fermi)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||