| Title | Failure to comply with TS requirements for CHRRMs |
| Description | The inspectors identified a green non-cited violation of Technical Specification (TS) 3.3.3.1 for failing to take the required TS actions after identifying a condition adverse to quality that affected the operability of the containment high range radiation monitors (CHRRMs) (RD-26-40 and RD-26-41). The licensee declared the CHRRMs for both Unit 1 and Unit 2 inoperable and identified alternate methods for assessing emergency action levels, performing core damage assessment and dose assessment. The licensee entered these issues in the corrective action program for resolution as AR2128751 and AR2135780. The performance deficiency was determined to be more than minor because it was associated with the Emergency Response Organization Performance attribute of the Emergency Preparedness Cornerstone and adversely affected the cornerstone objective of ensuring that the licensee is capable of implementing adequate measures to protect the health and safety of the public in the event of a radiological emergency. The finding was evaluated using IMC 0609, Appendix B, Emergency Preparedness Significance Determination Process. The finding is of very low safety significance (Green) because the finding affected an EAL that was rendered ineffective such that any Site Area Emergency would not be declared for a particular off-normal event, but because of other EALs, an appropriate declaration could be made in a degraded manner (e.g., delayed). This finding was not assigned a cross-cutting aspect because the issue did not reflect current licensee performance. |
| Site: | Saint Lucie |
|---|---|
| Report | IR 05000335/2016010 Section 1R21 |
| Date counted | Jun 30, 2016 (2016Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21N |
| Inspectors (proximate) | J Bartley S Herrick T Fanelli |
| Violation of: | Technical Specification |
| INPO aspect | |
| ' | |
Finding - Saint Lucie - IR 05000335/2016010 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Saint Lucie) @ 2016Q2
Self-Identified List (Saint Lucie)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||