05000335/FIN-2015004-07
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Licensee-Identified Violation |
| Description | Contrary to TS 6.8.1, Procedures and Programs, the licensee failed to implement the written procedures recommended in Appendix A of Regulatory Guide 1.33, Revision 2, dated February 1978, regarding PM of safety-related equipment. Specifically, Regulatory Guide 1.33 Appendix A Section 9.b states, in part, that system parts that have a specific lifetime should be replaced. The licensee implements this guidance in Regulatory Guide 1.33 by following the PM program, ER-AA-204, Preventive Maintenance Program Strategy, Revision 5, which details how PM should be developed and implemented for safety-related equipment. Section 3.2.9 of this procedure states, in part, that to ensure inclusion of vendor technical information, vendor maintenance recommendations should be included in PM bases and frequency requirements. The ESI-EMD owners group recommends a 10-year life for EDG speed switches based on electrolytic capacitor life expectancy. However, there is no evidence that the licensee considered vendor recommendations regarding the periodicity of EDG speed switch replacement when implementing its PM on the EDG. As a result, the existing PM for the speed switches was inadequate and led to the 1A EDG being rendered inoperable when the speed switch failed to function properly during manual local start of the EDG. This violation was associated with the Mitigating Systems Cornerstone and was determined to be of very low safety significance (Green) in accordance with Manual Chapter 0609 Appendix A, The Significance Determination Process (SDP) for Findings At-Power, because the finding did not result in a loss of system function or represent an actual loss of function of at least a single train for greater than its TS allowed outage time. The licensee entered this violation into its CAP as AR 2053060. |
| Site: | Saint Lucie |
|---|---|
| Report | IR 05000335/2015004 Section 4OA7 |
| Date counted | Dec 31, 2015 (2015Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Licensee-identified |
| Inspection Procedure: | |
| Inspectors (proximate) | A Goldau A Sengupta B Collins D Bacon J Reyes J Rivera-Ortiz L Suggs P Capehart T Morrissey |
| Violation of: | Technical Specification - Procedures Technical Specification |
| INPO aspect | |
| ' | |
Finding - Saint Lucie - IR 05000335/2015004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Saint Lucie) @ 2015Q4