05000335/FIN-2015003-01
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Unsecured Utility Cart With An Unrestrained Operating Pedestal Fan Near Safety-related ECCS Equipment |
Description | An NRC-identified, NCV of Technical Specification (TS) 6.8.1, Procedures and Programs, was identified for the licensees failure to implement written procedures covering activities referenced in NRC Regulatory Guide 1.33, Revision 2, dated February 1978. Specifically, the licensee failed to follow procedural requirements to properly secure a pedestal fan positioned on a wheeled cart to the extent required to prevent a potential for adverse interaction with safety-related systems, structures or components (SSCs) during a design basis seismic event. Failure to control equipment located near safety-related SSCs to prevent the equipment from interacting with safety-related SSCs during a design basis seismic event was a performance deficiency. Immediate corrective actions included removing the cart and fan assembly from the area and entering this issue into the corrective action program. The performance deficiency was more than minor because the issue was associated with the Mitigating Systems Cornerstone attribute of Protection Against External Factors (seismic) and affected the cornerstone objective of ensuring the availability, reliability, and capability of safety-related SSCs to respond to initiating events to prevent undesirable consequences. Specifically, during a design basis seismic event the unsecured cart and unrestrained fan could have damaged the emergency core cooling system low and high pressure safety injection flowrate transmitters causing control room operators to have a loss of safety injection flowrate indication and a small amount of system leakage during accident mitigation. Using Manual Chapter 0609.04, Significance Determination Process Initial Characterization of Findings, Table 2, dated June 19, 2012, the finding was determined to affect the Mitigating Systems Cornerstone. Manual Chapter 0609, Appendix A, Significance Determination Process (SDP) for Findings At-Power, Exhibit 2 - Mitigating Systems Screening Questions dated, June 19, 2012, was used to further evaluate this finding. The finding screened as Green because the inspectors answered No to all four screening questions. The finding involved the cross-cutting aspect in the area of human performance associated with training because the organization failed to provide training and ensure knowledge transfer to maintain a knowledgeable, technically competent workforce and instill nuclear safety values to ensure temporarily placed equipment located near safety-related SSCs was adequately secured to prevent interaction during a seismic event. |
Site: | Saint Lucie |
---|---|
Report | IR 05000335/2015003 Section 1R15 |
Date counted | Sep 30, 2015 (2015Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.15 |
Inspectors (proximate) | A Vargas C Thomas J Munday J Reyes S Sanchez T Hoeg T Morrissey |
Violation of: | Technical Specification - Procedures Technical Specification |
CCA | H.9, Training |
INPO aspect | CL.4 |
' | |