Title | Failure to Implement Vendor Described Preventive Maintenance on the Circulating Water Pump Motors |
Description | A self-revealing finding was identified for the licensees failure to implement vendor recommended preventive maintenance requirements to monitor and trend motor stator temperatures using the installed resistance temperature detector (RTDs) for the 1A2 Circulating Water Pump (CWP) motor. As a result of not trending 1A2 CWP motor performance, the pump was allowed to run to failure causing an unplanned reactor power transient. No violation of NRC regulatory requirements occurred. The inspectors determined that the finding did not represent a noncompliance because the performance deficiency involved non-safety related equipment. The licensee entered this issue in the corrective action program as condition report 1758355. Corrective actions included revising the circulating pump motor preventive maintenance procedure to include periodic monitoring and trending circulating water pump motor thermal performance using the installed stator Resistance Temperature Detectors (RTDs). The finding was more than minor because it affected the equipment reliability attribute of the Initiating Events cornerstone and affected the cornerstone objective to limit the likelihood of those events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Using NRC Manual Chapter 0609.04, SDP Phase 1 screening, the finding was determined to be of very low safety significance (Green) because it was a transient initiator, but did not contribute to both the likelihood of a reactor trip and the likelihood that mitigation equipment or functions will not be available. The finding did not have a cross-cutting aspect because the performance deficiency was not indicative of current plant performance. |
Site: | Saint Lucie |
---|---|
Report | IR 05000335/2012007 Section 4OA2 |
Date counted | Jun 30, 2012 (2012Q2) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71152 |
Inspectors (proximate) | G Hopper J Reyes J Sowa R Ng R Taylor T Chandler T Morrissey |
INPO aspect | |
' | |
Finding - Saint Lucie - IR 05000335/2012007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Saint Lucie) @ 2012Q2
Self-Identified List (Saint Lucie)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||