| Title | Failure to Perform Preventive Maintenance on the 1B Condensate Pump Discharge Check Valve |
| Description | An NRC identified finding was identified for the licensees failure to perform a preventive maintenance (PM) activity within its prescribed frequency on the 1B condensate pump discharge check valve. Consequently, the valve failed after a reactor trip and caused complications. No violations of NRC requirements were identified because the condensate pump discharge valve is non-safety related. The licensee entered this issue in the corrective action program as condition report 1755189. Corrective actions included revising the preventive maintenance procedure to initiate a condition report and require plant management approval prior to rescheduling a late PM. The finding was more than minor because it affected the equipment reliability attribute of the Initiating Events cornerstone and affected the cornerstone objective to limit the likelihood of those events that upset plant stability and challenge critical safety functions during shutdown as well as power operations. Using NRC manual Chapter 0609.04, Significant Determination Process Phase 1 screening, the finding was determined to be of very low safety significance (Green) because it was a transient initiator, but did not contribute to both the likelihood of a reactor trip and the likelihood that mitigation equipment or functions will not be available. The finding involved the cross-cutting area of Human Performance with a work control aspect. Specifically, the licensee did not plan work activities to support long-term equipment reliability, and maintenance scheduling was more reactive than preventive. |
| Site: | Saint Lucie |
|---|---|
| Report | IR 05000335/2012007 Section 4OA2 |
| Date counted | Jun 30, 2012 (2012Q2) |
| Type: | Finding: Green |
| cornerstone | Initiating Events |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | G Hopper J Reyes J Sowa R Ng R Taylor T Chandler T Morrissey |
| CCA | H.5, Work Management |
| INPO aspect | WP.1 |
| ' | |
Finding - Saint Lucie - IR 05000335/2012007 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Saint Lucie) @ 2012Q2
Self-Identified List (Saint Lucie)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||