Finding | |
|---|---|
| Title | |
| Description | The team identified a finding of very low safety significance involving a non-cited violation of 10 CFR Part 50, Appendix B, Criterion XVI, Corrective Action, in that FENOC did not take adequate corrective action following the identification of a condition adverse to quality. Specifically, in 2004, 2005 and 2006, FENOC identified that if the Unit 1 river water (RW) system or the Unit 2 service water (SW) system was aligned to the suction of the auxiliary feedwater (AFW) pumps it could result in blockage of cooling water flow for the pumps, but did not take actions to correct the deficiency. FENOC entered the issue into their corrective action program to correct the non-conformance. In addition, FENOC developed Operations Department standing orders to limit the use of TS action statement 3.7.6.a which credited the use of the lineup, and formalized compensatory actions to address an Appendix R compliance deficiency. The finding was more than minor because there was reasonable doubt as to the operability of the AFW system when supplied from RW or SW systems. In addition, the finding was associated with the design control attribute of the Mitigating Cornerstone and affected the cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Since the finding represented a potential loss of safety function, the team conducted Significance Determination Process (SDP) Phase 2 and Phase 3 analyses which determined the finding was of very low safety significance (Green). Finally, the finding had a cross-cutting aspect in the area of Problem Identification and Resolution, Corrective Action Program Component, because FENOC did not adequately evaluate this condition adverse to quality, including classifying, prioritizing, and evaluating for operability when it was identified in February 2004, and again in March 2005 and June 2006. (IMC 0305, Aspect P.1(c)). (Section 1R21.2.1.1 |
| Site: | Beaver Valley |
|---|---|
| Report | IR 05000334/2008008 Section 1R21 |
| Date counted | Dec 31, 2008 (2008Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.21 |
| Inspectors (proximate) | P Kaufman K Mangan S Pindale W Sherbin J Tifft M Balazik J Chiloyen |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Beaver Valley - IR 05000334/2008008 | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Beaver Valley) @ 2008Q4
Self-Identified List (Beaver Valley)
| |||||||||||||||||||||||||||||||||||||||||||||