Finding | |
|---|---|
| Title | Failure To Adequately Implement Design Control Measures For The Fire Protection Program |
| Description | The inspectors identified a Green non-cited violation of BSEP Unit 1 Updated Facility Operating License DPR-71, and the Unit 2 Updated Facility Operating License DPR-62, Condition 2.B.(6), for the licensees failure to implement adequate design control measures for the fire protection program. Plant drawings which specify the configuration of fire suppression sprinklers are inconsistent and inadequate in that they do not provide complete details for sprinkler spray shields. Dimensions for spray shields on some drawings are incomplete because they dont list all of the necessary critical dimensions. Therefore, some ceiling-level spray shields were incorrectly installed and extended below the sprinklers fusible links. This would have delayed sprinkler response in a fire. After the identification of this design control issue, the licensee implemented corrective actions which included repairing or replacing the degraded sprinklers. This finding was entered into the licensees corrective action program as NCR #367339. The licensees failure to adequately implement design control measures for the fire protection program as required by the operating license (condition 2.B(6)) was a performance deficiency. The finding was determined to be more than minor because it affected the Mitigating Systems cornerstone objective of availability, reliability, and capability of the fixed fire suppression systems and was associated with the design control and protection against external factors (fire) attribute. Specifically, this failure could affect the ability of the water sprinkler system to respond to a fire because the incorrectly installed spray shields delay the ceiling-level sprinklers response times. The issue was determined to be of very low safety significance (Green) using MC 0609, Appendix F, Attachment 1, because the category of fixed fire suppression was evaluated as having low degradation. The system had low degradation because the sprinkler system is expected to display nearly the same level of effectiveness and reliability as it would, had the degradation not been present. This finding has no cross-cutting aspect because the design drawing deficiency occurred when the plants were licensed and it is not indicative of current licensee performance |
| Site: | Brunswick |
|---|---|
| Report | IR 05000324/2009005 Section 1R05 |
| Date counted | Dec 31, 2009 (2009Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.05 |
| Inspectors (proximate) | M Bates L Miller R Musser G Kolcum |
| INPO aspect | |
| ' | |
Finding - Brunswick - IR 05000324/2009005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Brunswick) @ 2009Q4
Self-Identified List (Brunswick)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||