05000321/FIN-2011003-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | Failure to consider potential adverse system interactions when developing procedure to open SRVs without power |
Description | An NRC-identified NCV of 10 CFR 50 Appendix B, Criterion V, Instructions, Procedures, and Drawings, was identified for failure to establish adequate procedures that address potential adverse system interactions when opening safety relief valves (SRV) without power. Immediate corrective actions taken by the licensee include changing procedure 31EO-TSG-001-0, Attachment 6, SRV Actuation Without Power to Allow Injection with Portable Pump, to ensure the SRV control circuits are isolated electrically from the direct current (DC) busses prior to installing the portable DC power supply. This violation has been entered into the licensees corrective action program as CR 2011106008. Failure to address potential adverse system interactions when developing procedures affecting quality is a performance deficiency. This performance deficiency is more than minor because it is associated with the Procedural Quality attribute of the Mitigating Systems Cornerstone and adversely affects the cornerstone objective to ensure the availability, reliability, and capability of the safety relief valves to reduce reactor pressure in response to a loss of alternating current (AC) and DC power event. Because this finding is associated with B.5.b mitigation strategies, the finding was assessed using MC 0609 Appendix L, B.5.b Significance Determination Process, Table 2. The inspectors performed an initial screening and determined the finding did not meet the criteria listed within Table 2 for greater than Green significance therefore this finding was screened as Green. Because the mitigating strategy was developed and implemented in site procedures in 2007, the performance deficiency occurred outside the past three years and no cross-cutting aspect is assigned. |
Site: | Hatch ![]() |
---|---|
Report | IR 05000321/2011003 Section 4OA5 |
Date counted | Jun 30, 2011 (2011Q2) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | |
Inspectors (proximate) | D Hardage E Morris S Shaeffera Nielsenb Collins C Dykes D Hardage E Morris J Rivera R Bernhard R Kellner S Shaeffer T Chandler |
INPO aspect | |
' | |
Finding - Hatch - IR 05000321/2011003 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Hatch) @ 2011Q2
Self-Identified List (Hatch)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||