05000311/LER-1981-088, Forwards LER 81-088/03L-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 81-088/03L-0.Detailed Event Analysis Encl
ML20010G449
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/09/1981
From: Midura H
Public Service Enterprise Group
To: Haynes R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20010G450 List:
References
NUDOCS 8109210177
Download: ML20010G449 (3)


LER-1981-088, Forwards LER 81-088/03L-0.Detailed Event Analysis Encl
Event date:
Report date:
3111981088R00 - NRC Website

text

-

0 PSEG Public Service Electric and Gas Company P.O. Box 168 Hancocks Bridge, New Jersey 08038 Salem Generating Station September 9, 1981 Mr.

R.

C.

Haynes Director of USNRC Office of Inspection and Enforcement Region 1 631 Park Avenue k

King of Prussia, Pennsylvania 19406

Dear Mr. Haynes:

LICENSE NO. DPR-75 DOCKET NO. 50-311 REPORTABLE OCCURRENCE 81-88/03L Pursuant to the requirements of Salem Generating Station Unit No. 2 Technical Specifications, Section 6.9.1.9.b, we are submitting Licensee Event Report for Reportable Occurrence 81-88/03L.

This report is required within thirty (30) days of the occurrence.

Sincerely yours, l

j}

)f w~

H.

J. Midura Manager - Salem Generating Station V

e..'.f ' " Jj,

- s CC:

R. A.

Uderitz

/.

%' Q / / r Q\\

/'.z[)[t/(j ' [

General Manager - Nuclear Production 8,7 kps40 d *,g,hg, %

Director, Office of Inspection e

and Enforcement (30 copies) p.,

N

'Y/

Director, Office of Management

-(\\"pj Information and Prograra Control 9

'\\

(3 copies)

N u[y yb I

g 6t g i

(

8109210177 810909 l

gDRADOCK 05000311 im-.~.oppRaple es2 tem 2.sw neo I

N-

Report Number:

81-88/03L Report Date:

9-9-81 Occurrence Date:

8-14-81 Facility:

Salem Generating Station, Unit 2 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

2C Diesel Generator - Inoperable This report was initiated by Incident Report 81-330.

CONDITIONS PP.IOR TO OCCURRENCE:

Mode 1 - Rx Power 90% - Unit Load 1010 MWe DESCRIPTION OF OCCURRENCE:

On August 13, 1981, sparks were noticed emanating from the motor of the prelubrication pump on 2C diesel generator.

The motor was sub-sequently removed, and sent for rewinding.

No action statement was entered because the prelubrication pump was not specified as an item which would render the diesel inoperable.

On August 14, 1981, Alco Engine Division was consulted as to the starting ability of the diesel without a prelubrication pump.

They stated that after a period of twelve hours without prelubrication, the diesel will not attain 900 rpm in 10 seconds.

At 1130 hours0.0131 days <br />0.314 hours <br />0.00187 weeks <br />4.29965e-4 months <br />, August 14, 1981, 2C diesel generator was declared inoperable, and action-statement 3.8.1.1.a was entered.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

2C diesel was inoperable due to lack of lubrication for greater than 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> from the prelubrication pump.

l l

ANALYSIS OF OCCURRENCE:

l Technical specification 3.8.1.1.a requires:

With either an offsite circuit or diesel generator inoperable, restore at least 2 offsite circuits and three diesel genarators to operable status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least hot standby within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in cold shutdown within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

l Q

LER 81-88/03L.

CORRECTIVE ACTION

The motor of the prelubrication pump was. rewound and reinstalled.

The pump assembly was tested satisfactorily.

Surveillance procedure SP(O) 4.8.1.1.2 was satisfa ctorily performed on 2C diesel within the required starting time.

At 2100 hours0.0243 days <br />0.583 hours <br />0.00347 weeks <br />7.9905e-4 months <br />, August 15, 1981, 2C diesel was returned to service and action statement 3.8.1.1.a was terminated.

FAILURE DATA:

l Alco Engine Division Precirculating Lubricating Oil Pump Part No. 23900815 Prepared By F.

Dickey

/[d lyh[<,tw Managef - salem' Generating Station SORC Meeting No.

81-88