05000311/LER-1981-061, Forwards LER 81-061/03L-0.Detailed Event Analysis Encl

From kanterella
Jump to navigation Jump to search
Forwards LER 81-061/03L-0.Detailed Event Analysis Encl
ML20010C718
Person / Time
Site: Salem PSEG icon.png
Issue date: 08/12/1981
From: Uderitz R
Public Service Enterprise Group
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20010C719 List:
References
NUDOCS 8108200341
Download: ML20010C718 (3)


LER-1981-061, Forwards LER 81-061/03L-0.Detailed Event Analysis Encl
Event date:
Report date:
3111981061R00 - NRC Website

text

.

y.

- a, p.

fe O PSEG

~

Pobiic Service Electric and Gas Company 80 Park Plaza Newark, N.J. 07101 Phone 201/430-7000 August 12, 1981

<b

^ 'tig\\

o

- Mr. Eoyce~H. Grier [f

'e I'

Director'of USNRC S'

~

J

- O Office of Inspection ~and Enforcement 2

ilbC 1 S ?S3% 1 Region i' d31 Park Avenue

(

8h 84 u us em u f y d. l

"'C W 1 King of Prussia, Pennsylvania 19406 g'

Dear Mr. Crier:

LICENSE NO. DPR-75 DOCKET NO.-50-311 REPORTABLE OCCURRENCE 81-61/03L Pursuant to the requirements of Salem Generating Station Unit No. 2 Technical Specifications, Section 6.9.1.9.b, we are submitting-Licensee Event Report for Reportable Occurrence 81-61/03L.

This repc rt is required within thirty (30) days of the 7ccurrence.

Sincerely yours,

/

vf R.

A.

Uderitz e.'

General Manager -

Nuclear Production CC:

Director, Office of inspection and Enforcement-(30 copies)

Director, Office of Management Information and Program Control (3 copies)

S

/ /

I d1082OO341 8108121 3Pls -

PDR ADOCK 05v00311 S-POR

s-L Report Number:

81-61/03L Report Date:

August 12, 1981 Occurrence Date:

7-13-81 Facility:

Salem Generating Station, Unit 2 Public Service Electric & Gas Company Hancocks Bridge, New Jersey 08038 IDENTIFICATION OF OCCURRENCE:

Individual Rod Position Indicators - ISB2 and 2SB2 - Inoperable.

This report was. initiated by Incident Reports81-246 and 81-247.

CONDITIONS PRIOR TO OCCURRENCE:

Mode 2 - Rx Power 3% - Unit Load 0 MWe DESCRIPTION OF OCCURRENCE:

At 0855.and 1042 hours0.0121 days <br />0.289 hours <br />0.00172 weeks <br />3.96481e-4 months <br />, respectively, on July 13, 1981, the control.

operator noticed that the individual red position indicators for rods'lSB2 and 2SB2 were in disagreement with the shutdown rod bank demand indicators by greater than + 12 steps.

The individual rod position indicators were declared Inoperable at said hours, and action statement 3.1.3.2.1.a was entered.

This occurrence constituted operation in a degraded mode in accord-ance with technical specification 6.9.1.9.b.

DESIGNATION OF APPARENT CAUSE OF OCCURRENCE:

Equipment failure.

The individual rod position indicators for rods ISB2 and 2SB2 were not in agreement with the shutdown rod bank demand indicators due to failure of the operational amplifiers on the amplifier boards in the indicators.

ANALYSIS OF OCCURRENCE:

Technical Specification 3.1.3.2.1 requires that in modes 1 and 2 with a maximum of one rod position indicator per bank inoperable eicher:

1.

Determine the position of the non-indicating rod (s) indirectly by the movable incore detectors at least once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and immediately after any motion of the non-indicating rod which exceeds 24 steps in one direction since the last determination of the rod's

- position, or 2.

Reduce thermal power to less than-50% of rated thermal power within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.

(LER.81-61/03L~ 8/12/81l

- s CORRECTIVE. ACTION:

'In the position indicator for rod lSE2, the amplifier board was replaced..

In the position indicator-for rod 2SB2, the operational amplifier on the amplifier board was replaced.

The position indicators for rods ISB2 and 2SB2 were recalibrated, tested. satis-factorily, and returned to service.

Action statement.3.1.3.2.1.a was terminated at'1040 and 1243 hours0.0144 days <br />0.345 hours <br />0.00206 weeks <br />4.729615e-4 months <br />, respectively,'on July 13, 1981.

' FAILURE DATA:

Bailey Instrument-Co., Inc.

Bailey Edgewise Indicator Model R42 Amplifier Board #6627353-2 and Operational Amplifier LM-307H Prepared By F.

Dickey t,

W

~

Manager - Salem Generating Station SORC Meeting No.

81-74 N

j c

f 4

.4 l

-~