ML20010C719

From kanterella
Jump to navigation Jump to search
Forwards LER 81-061/03L-0.Detailed Event Analysis Encl
Date released: 01/24/2020 Download: ML20010C719


LER 81-061/03L-0:on 810713,disagreement Between Individual Rod Position Indicators for Rods 1SB2 & 2SB2 & Shutdown Rod Bank Demand Indicators Exceeded Tech Spec.Caused by Failed Operational Amplifiers.Amplifiers Replaced
ML20010C723
Person / Time
Site: Salem 
Issue date: 08/12/1981
From: Dickey F
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20010C723 (1)
Forwards LER 81-061/03L-0.Detailed Event Analysis Encl
ML20010C718
Person / Time
Site: Salem 
Issue date: 08/12/1981
From: Uderitz R
Public Service Enterprise Group
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20010C718 (3)