Finding | |
---|---|
Title | Inadequate Digital Feedwater Design Change Evaluation |
Description | A self-revealing Green finding against procedure CC-AA-103, Configuration Change Control for Permanent Physical Plant Changes, Revision 15, was identified when PSEG did not adequately evaluate a modifications effect on existing design and operating margins. Specifically, an Advanced Digital Feedwater Control System (ADFCS) modification introduced a steam generator feedwater pump (SGFP) over-acceleration trip feature that was not evaluated and resulted in a SGFP trip and auxiliary feedwater (AFW) actuation. PSEG corrective actions included re-establishing main feedwater, making a report to the NRC via ENS 51738 for the AFW actuation, and entering this in their Corrective Action Program (CAP) as 20718519. The inadequate evaluation of the ADFCS modifications effect on existing design and operating margins was a performance deficiency. The issue was determined to be more than minor since it was similar to IMC 0612, Appendix E, example 3b in that the design was not correctly translated and resulted in system operation being adversely affected by a SGFP trip and an AFW system actuation. It was also more than minor since it was associated with the design control attribute (plant modification) of the Initiating Events cornerstone and adversely affected its objective to limit the likelihood of events that upset plant stability and challenge critical safety functions. The finding was evaluated in accordance with IMC 0609, Attachment 4 and Appendix A, where it was screened to Green since the transient did not result in both a reactor trip and loss of mitigation equipment relied upon to transition the plant from the onset of a trip to a stable shutdown condition (loss of feedwater). The finding had a cross-cutting aspect in the area of Human Performance, Change Management, in that, PSEG did not anticipate, manage, and communicate the effects of the over-acceleration trip change in the ADFCS modification to ensure unintended consequences were avoided. |
Site: | Salem |
---|---|
Report | IR 05000311/2016001 Section 1R15 |
Date counted | Mar 31, 2016 (2016Q1) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71111.15 |
Inspectors (proximate) | A Ziedonis F Bower P Finney P Presby R Barkley R Nimitz |
CCA | H.3, Change Management |
INPO aspect | LA.5 |
' | |
Finding - Salem - IR 05000311/2016001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Salem) @ 2016Q1
Self-Identified List (Salem)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||