fjg

., e c,o an+ s a

GMi g

e ww mWwt.

w w Of r.13 A10 : 3" Florida

.P..o..w..e...r.

December 7,1982

  1. 3F-1282-03 File: 3-0-3-a-1 Mr. James P. O'Reilly l

Regional Administrator, Region II U.S. Nuclear Regulatory Commission Office of Inspection & Enforcement 101 Marietta Street N.W., Suite 3100 Atlanta, Ga. 30303

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 Licensee Event Report No.82-070

Dear Mr. O'Reilly:

Enclosed please find Licensee Event Report No.82-070 and the attached supplementary information sheet, which are submitted in accordance with Technical Specification 6.9.1.9.b.

Very truly yours,

/

G. R. Westafer Manager Nuclearing Licensing and Fuel Management PGH/ mig Enclosure cc:

Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555 ca 4:0Y gyn h

(f'k 8212150099 821207 PDR ADOCK 05000302 S

PDR General Office 3201 Tn rty-sourin sir t soutn. P.O Box 14042. st. Petersburg. Florida 33733 e 813-866-5151

.~.

SUPPLEMENTARY INFORMATION REPORT NO:

50-302/82-070/03L-0 FACILITY:

Crystal River Unit #3 REPORT DATE:

December 7,1982 OCCURRENCE DATE:

November 7,1982 IDENTIFICATION OF OCCURRENCE:

Channel "B" of the Nuclear Overpower Instrumentation, a Reactor Protection System, was inoperable. Technical Specification 3.3.1.1. requires initiation of Action Statement Two with one of the four Nuclear Overpower Channels inoperable.

CONDITIONS PRIOR TO OCCURRENCE:

i MODE 1 (69% Full Power).

DESCRIPTION OF OCCURRENCE:

At 0734 on November 7,1982, Reactor Coolant Flow Transmitter (RC-14A-FT2) failed.

Failure of the transmitter caused Channel"B" of the Nuclear Overpower Instrumentation to be inoperable.

Channel "B" was verified in the tripped condition.

The minimum channels i

operable requirement was met; Channels A, C, and D were available. The Quadrant Power Tilt l

was monitored ever-* 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />. Both transmitters in Channel "B" were recalibrated. During calibration operations, the companion flow transmitter (RC-14B-FT2) sustained damage.

Channel was restored to operability at 1500 on November 9,1982.

l DESIGNATION OF APPARENT CAUSE:

The failure of RC-14A-FT2 was caused by a shorted capacitor in the transmitter power supply,.

The failure of RC-14B-FT2 was caused by inoperable bellows. At this time, it is believed that the bellows failed due to improperly isolating the transmitter to perform a channel calibration.

ANALYSIS OF OCCURRENCE:

There was no effect on public health or safety. Nuclear Overpower Channels A, C, and D were operable to provide the necessary trip function.

CORRECTIVE ACTION

The capacitor and bellows were replaced, the channel was recalibrated and functionally tested satisfactorily.

FAILURE DATA:

This is the fourth fai!vre for Channel "B" and the twentieth report under Technical Specification 3.3.1.1.