05000298/FIN-2017001-03
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Identify a Condition Adverse to Quality |
| Description | The inspectors identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, associated with the licensees failure to identify a condition adverse to quality for Division 1 residual heat removal service water booster pump A, in accordance with Station Procedure 0-CNS-LI-102, Corrective Action Process, Revision 6. Specifically, on January 5, 2017, the inspectors identified an oil level lower than normally expected, oil on the pump skid, and an oil droplet formed on the Division 1 residual heat removal service water booster pump A inboard bearing sight glass. The inspectors informed the control room of this condition, and the licensee determined the oil leakage from the pumps sight glass would have prevented the pump from operating for the required 30 days during a design basis accident. The immediate corrective action was to repair the Division 1 residual heat removal service water booster pump A inboard bearing sight glass, restoring operability of the pump. The licensee entered this deficiency into the corrective action program as Condition Report CR-CNS-2017-00054. The licensees failure to identify a condition adverse to quality for Division 1 residual heat removal service water booster pump A, in violation of Station Procedure 0-CNS-LI-102, was a performance deficiency. The performance deficiency was determined to be more than minor, and therefore a finding, because it was associated with the equipment performance attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure availability, reliability, and capability of systems that respond to initiating events. Specifically, the oil leakage from the service water booster pump A inboard bearing sight glass would have prevented the pump from operating for its required 30-day mission time during a design basis accident and resulted in the pump being declared inoperable. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, dated June 19, 2012, the inspectors determined that the finding had very low safety significance (Green) because it: was not a design deficiency; did not represent a loss of system and/or function; did not represent an actual loss of function; did not represent an actual loss of function of at least a single train for longer than its technical specification allowed outage time; and did not result in the loss of a high safety significant nontechnical specification train. The finding had a cross-cutting aspect in the area of human performance associated with challenge the unknown because the licensee failed to stop when faced with uncertain conditions and failed to ensure that risks are evaluated and managed before proceeding. Specifically, the licensee did not maintain a questioning attitude during job-site reviews to identify and resolve unexpected conditions, including lower than the expected oil level in the service water booster pump A inboard bearing sight glass, oil on the pump skid, and an oil droplet formed on the bottom of the sight glass [H.11]. |
| Site: | Cooper |
|---|---|
| Report | IR 05000298/2017001 Section 1R15 |
| Date counted | Mar 31, 2017 (2017Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.15 |
| Inspectors (proximate) | C Henderson E Uribe G Warnick I Anchondo J Watkins P Elkmann P Voss R Deese |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion V |
| CCA | H.11, Challenge the Unknown |
| INPO aspect | QA.2 |
| ' | |