05000298/FIN-2017001-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Failure to Identify a Condition Adverse to Quality Associated with the 250 Vdc Electrical System |
| Description | The inspectors identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures, and Drawings, associated with the licensees failure to identify a condition adverse to quality associated with Station Procedure 2.2.24.1, 250 Vdc Electrical System (Div 1), Revision 14, in accordance with Station Procedure 0-CNS-LI-102, Corrective Action Process, Revision 6. Specifically, the licensee failed to identify that Station Procedure 2.2.24.1 contained inadequate instructions to ensure the oncoming charger 1C output voltage was matched with the bus 1A voltage when transferring bus 1A from charger 1A to charger 1C, so that technical specification bus voltage requirements would remain met. This resulted in an unexpected and initially unrecognized decline in voltage on the bus to below the required minimum of 260.4 Vdc. This condition required the licensee to declare the Division 1 250 Vdc electrical system and Division 1 residual heat removal low pressure coolant injection system inoperable. The immediate corrective action was to adjust the charger 1C float voltage greater than 260.4 Vdc to restore operability of the Division 1 250 Vdc electrical and residual heat removal low pressure coolant injection systems. The licensee entered this deficiency into the corrective action program as Condition Reports CR-CNS-2016-08658 and CR-CNS-2017-00750. The licensees failure to identify a condition adverse to quality associated with Station Procedure 2.2.24.1, to ensure technical specification bus voltage requirements were met, in violation of Station Procedure 0-CNS-LI-102, was a performance deficiency. The performance deficiency was determined to be more than minor, and therefore a finding, because it was associated with the procedural quality attribute of the Mitigating Systems Cornerstone and adversely affected the cornerstone objective to ensure availability, reliability, and capability of systems that respond to initiating events. Specifically, charger 1C, when in service, did not maintain battery 1A terminal voltage within the requirements of Surveillance Requirement 3.8.4.1, which required the licensee to declare the Division 1 250 Vdc electrical system and the Division 1 residual heat removal low pressure coolant injection system inoperable. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, dated June 19, 2012, the inspectors determined that the finding had very low safety significance (Green) because it: was not a design deficiency; did not represent a loss of system and/or function; did not represent an actual loss of function; did not represent an actual loss of function of at least a single train for longer than its technical specification allowed outage time; and did not result in the loss of a high safety-significant, nontechnical specification train. The finding had a cross-cutting aspect in the area of problem identification and resolution associated with evaluation. Specifically, the licensee failed to thoroughly evaluate the charger 1C float voltage issue to ensure that the resolution addressed the cause and extent of condition commensurate with the safety significance [P.2]. |
| Site: | Cooper |
|---|---|
| Report | IR 05000298/2017001 Section 1R12 |
| Date counted | Mar 31, 2017 (2017Q1) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.12 |
| Inspectors (proximate) | C Henderson E Uribe G Warnick I Anchondo J Watkins P Elkmann P Voss R Deese |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion V Technical Specification |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Cooper - IR 05000298/2017001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Cooper) @ 2017Q1
| |||||||||||||||||||||||||||||||||||||||||||||||||||||