| Title | Failure to Follow Procedure and Initiate Condition Reports When Degraded Nonconforming Conditions Were Identified |
| Description | The inspectors identified a non-cited violation of 10 CFR Part 50, Appendix B, Criterion V, Instructions, Procedures and Drawings, associated with the licensees failure to follow the requirements of Station Procedure 0.5CR, Condition Report Initiation, Review, and Classification, Revision 19, and enter conditions adverse to quality in the stations corrective action program. Specifically, station personnel performing walkdowns for Temporary Instruction 2515/187, Inspection of Near-Term Task Force Recommendation 2.3 Flooding Walkdowns, failed to initiate condition reports for degraded or nonconforming conditions as they were identified. The licensee entered this issue into their corrective action program for resolution as Condition Report CR-CNS-2012-06753. The failure to follow the requirements of Station Procedure 0.5CR and initiate condition reports when degraded nonconforming conditions were identified was a performance deficiency. The performance deficiency was determined to be more than minor, and is therefore a finding, because it is associated with the equipment performance attribute of the Mitigating Systems Cornerstone, in that the failure to write condition reports when degraded conditions were identified resulted in equipment being in an unevaluated state and its ability to perform its function being unknown, thereby affecting the associated cornerstone objective to ensure availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process For Findings At-Power, the finding was determined to have very low safety significance (Green) because the finding did not involve the loss or degradation of equipment or function specifically designed to mitigate a flooding event. The inspectors determined that the apparent cause of this finding was that licensee personnel failed to make safety/risk-significant decisions using a systematic process when degraded conditions were identified during in plant walkdowns. Therefore, the finding has a cross-cutting aspect in the area of human performance associated with the decision making component because the licensee failed to make safety/risk-significant decisions using a systematic process when faced with uncertain plant conditions. |
| Site: | Cooper |
|---|---|
| Report | IR 05000298/2012005 Section 4OA5 |
| Date counted | Dec 31, 2012 (2012Q4) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | |
| Inspectors (proximate) | J Melfi J Josey J Laughlin D Proulx T Buchanan N Greene T Farina C Henderson S Garchow |
| CCA | H.13, Consistent Process |
| INPO aspect | DM.1 |
| ' | |
Finding - Cooper - IR 05000298/2012005 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Cooper) @ 2012Q4
Self-Identified List (Cooper)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||