Finding | |
|---|---|
| Title | Process Radiation Monitor Subsystems 10 CFR 50.65(a)(2) Not Met |
| Description | Inspectors identified a Green NCV of 10 CFR 50.65 (a)(2), because Entergy did not adequately demonstrate that the performance of the process radiation monitors (PRMs) was effectively controlled through performance of appropriate preventive maintenance. Specifically, Entergy did not identify and properly account for functional failures of four PRM subsystems in July 2014 and February, April, and July 2015; and did not recognize that the subsystems had exceeded their performance criteria and required a Maintenance Rule (a)(1) evaluation. Entergy entered the issue into the CAP under CR-2016-05564. Entergy performed the Maintenance Rule (a)(1) evaluation, and placed them into (a)(1) where they will be monitored against specific goals. The finding is more than minor because it is associated with the Plant Facilities/Equipment and Instrumentation attribute of the Public Radiation Safety cornerstone and affects the cornerstone objective of ensuring the adequate protection of public health and safety from exposure to radioactive materials released into the public domain as a result of routine civilian nuclear reactor operation. Specifically, following the failures of the Main Stack Normal Range subsystem in July 2014, the Reactor Building Closed Cooling Water (RBCCW) subsystem in February 2015, the Shared Components subsystem in April 2015, and the Torus Containment High Radiation Monitoring System (CHRMS) subsystem in July 2015, Entergy did not identify the failures as functional failures, and consequently, did not establish goals and monitoring criteria in accordance with 10 CFR 50.65(a)(1). The inspectors determined that the failures demonstrated that the performance of the subsystems was not being effectively controlled through appropriate preventive maintenance, because the incorrect screenings resulted in exceedance of the subsystems performance criteria and placement in (a)(1) status. The inspectors evaluated the significance of this finding using IMC 0609, Appendix D, Public Radiation Safety Significance Determination Process. The finding is of very low safety significance (Green) because the finding was in the Effluent Release Program, but did not result in a failure to implement the Effluent Release Program, and did not result in dose to the public in excess of 10 CFR 50, Appendix I criterion or 10 CFR 20.1301(e) limits. The inspectors determined that the finding has a cross-cutting aspect in the area of Problem Identification and Resolution, Evaluation, in that the organization did not thoroughly evaluate issues to ensure that resolution addressed causes and extent of conditions commensurate with their safety significance. Specifically, Entergy identified all of the failures of the PRM subsystems, however, Entergy did not thoroughly evaluate the failures as maintenance rule functional failures. |
| Site: | Pilgrim |
|---|---|
| Report | IR 05000293/2016003 Section 1R12 |
| Date counted | Sep 30, 2016 (2016Q3) |
| Type: | NCV: Green |
| cornerstone | Pr Safety |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.12 |
| Inspectors (proximate) | A Burritt B Fuller B Pinson D Werkheiser E Burket E Carfang J Brand J Pfingstein L Dumont M Fannon M Modes S Rich T Dunn |
| Violation of: | 10 CFR 50.65 10 CFR 50.65(a)(1) 10 CFR 50.65(a)(2) |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |