Finding | |
---|---|
Title | Inadequate Documentation of the Adequacy of Design for the Pumps that Transfer Fuel Oil from Storage Tank FO-10 to FO-1 |
Description | The inspectors identified a Green noncited violation of 10 CFR Part 50, Appendix B, Criteria III due to the failure of the licensee to perform suitable testing to determine the adequacy of the design of equipment related to transferring diesel fuel from one storage tank to another. Specifically, the inspectors questioned whether fuel oil transfer pump FO-37 or a portable hand pump to be used in the event that FO-37 was unavailable to transfer fuel from storage tank FO-10 to FO-1 would be able to perform the design function. No calculations or previous testing documentation could be provided and when tested to demonstrate that the portable hand pump could perform the intended design function, the portable hand pump failed. Subsequently, the licensee evaluated that fuel oil transfer pump FO-37 is adequately designed to transfer fuel oil from FO-10 to FO-1. The licensee entered this issue into the corrective action program as Condition Reports 2010-3123, 2010-3921, and 2010-4315.
The inspectors determined that the licensees failure to provide calculations or testing documentation that fuel oil transfer pump FO-37 or the designated portable hand pump could perform the intended design function was a performance deficiency. This finding is greater than minor because it affected the Mitigating System Cornerstone objective of ensuring the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences, and the equipment performance attribute to maintain availability and reliability of the diesel generators. Because this finding occurred while the unit was operating at full power, the inspectors used Inspection Manual Chapter 0609 to determine its significance. Using Attachment 4 of that chapter, the inspectors determined that this finding has a very low safety significance (Green) because it was not a design or qualification deficiency, does not represent an actual loss of safety function nor did it screen as potentially risk significant for external events. Since the finding is not indicative of current licensee performance, there is no crosscutting aspect assigned to this finding (Section 1R15). |
Site: | Fort Calhoun |
---|---|
Report | IR 05000285/2010004 Section 1R15 |
Date counted | Sep 30, 2010 (2010Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.15 |
Inspectors (proximate) | L Ricketson J Kirkland D Stearns G George J Clark D Graves I Anchondo W Schaup T Buchanan R Hickok N Greene J Wingebach |