Finding | |
|---|---|
| Title | Inadequate Corrective Actions for Unexpected SRV Low Low Set Trips Encountered During Surveillance Testing |
| Description | The inspectors identified a finding of very low safety significance and NCV of10 CFR 50, Appendix B, Criterion XVI, for the licensees failure to adequately evaluate and take corrective actions for a condition adverse to quality. Specifically, the licensee failed to appropriately evaluate the implications of the unexpected trips of high/low pressure switches, PSHL-4065A and PSHL-4066A, during the January 28, 2009, performance of the SRV low low set system quarterly tests and implement appropriate corrective actions. The failure to adequately evaluate the unexpected trips and correct the condition adverse to quality directly contributed to a repeat occurrence and subsequent unplanned Technical Specification Action entry during the January 27, 2010, performance of the same surveillance test. The licensee entered the issue into their corrective action program. The inspectors determined that the performance deficiency affected the cross-cutting aspect in the area of Problem Identification and Resolution, having corrective action program components, and involving aspects associated with the licensee thoroughly evaluating problems such that the resolutions address causes and extent of conditions, as necessary. P.1(c) The inspectors determined that the performance deficiency was more than minor and a finding because it was associated with the Barrier Integrity Cornerstone objective to provide reasonable assurance that physical design barriers protect the public from radionuclide releases caused by accidents or events. The inspectors evaluated the finding using IMC 0609, Appendix A, Attachment 1, Significance Determination of Reactor Inspection Findings for At-Power Situations, using the Phase 1 Worksheet for the Barrier Integrity Cornerstone. Since the inspectors answered no to all four questions in the Containment Barrier column of the Characterization Worksheet for Initiating Events, Mitigating Systems, and Barrier Integrity Cornerstones, the inspectors concluded that the finding was of very low safety significance |
| Site: | Monticello |
|---|---|
| Report | IR 05000263/2010002 Section 4OA2 |
| Date counted | Mar 31, 2010 (2010Q1) |
| Type: | NCV: Green |
| cornerstone | Barrier Integrity |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71152 |
| Inspectors (proximate) | K Riemer S Thomas L Haeg S Bakhsh J Bozga M Learn |
| CCA | P.2, Evaluation |
| INPO aspect | PI.2 |
| ' | |
Finding - Monticello - IR 05000263/2010002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Monticello) @ 2010Q1
Self-Identified List (Monticello)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||