05000263/FIN-2009004-05
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Licensee-Identified Violation |
| Description | Title 10 CFR 50, Appendix B, Criterion XVI, Corrective Action, requires, in part, that measures shall be established to assure that conditions adverse to quality are promptly identified and corrected. Contrary to this requirement, the licensee did not promptly identify on July 1, 2009, that a measured flow rate outside of the acceptance criteria of surveillance test 0253-01 rendered the A standby gas treatment (SBGT) system inoperable. Due to the failure to promptly identify this condition adverse to quality, the A SBGT system was not declared inoperable until July 20, 2009, after the operations duty shift manager became aware of the test results from July 1, 2009. The inspectors determined that this issue was a performance deficiency because it was the result of the failure to meet a requirement, and the cause was reasonably within the licensees ability to foresee and correct and should have been prevented. The inspectors determined that the finding was more than minor because it involved the configuration control attribute of the Barrier Integrity Cornerstone objective to provide reasonable assurance that physical design barriers (containment) protect the public from radionuclide releases caused by accidents or events. The licensee entered the issue into the corrective action program as CAP 01189968.The inspectors applied IMC 0609, Attachment 4, Phase 1 Initial Screening and Characterization of Findings to this finding. Under Column 4 of the Table 4a worksheet, the inspectors answered Yes to Question 1, since the finding only represented a degradation of the radiological barrier function provided by the SBGT system. Therefore, the finding was considered to be of very low safety significance. |
| Site: | Monticello |
|---|---|
| Report | IR 05000263/2009004 Section 4OA7 |
| Date counted | Sep 30, 2009 (2009Q3) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | Licensee-identified |
| Inspection Procedure: | |
| Inspectors (proximate) | J Bozga J Corujo-Sandin K Riemer C Brown S Thomas L Haeg |
| INPO aspect | |
| ' | |
Finding - Monticello - IR 05000263/2009004 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Monticello) @ 2009Q3
Self-Identified List (Monticello)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||