05000263/FIN-2010002-02
From kanterella
Jump to navigation
Jump to search
Finding | |
---|---|
Title | SRV Low Low Set Surveillance Procedure Implementation |
Description | The inspectors identified a finding of very low safety significance and NCV of Technical Specification 5.4.1 for the licensee failing to appropriately implement an applicable procedure recommended in Regulatory Guide 1.33, Revision 2, Appendix A, February 1978. Specifically, when unexpected local alarms were received during the performance of the safety relief valve (SRV) low low set system quarterly test, Instrument and Control (I&C) personnel elected to attempt to clear the alarms prior to notifying operations and without fully understanding which alarms were present. The surveillance procedure provided no guidance on how to clear the unexpected module trip alarms and relay energized lights. The licensee entered this issue into their corrective action program. The inspectors determined that the performance deficiency affected the cross-cutting area of Human Performance, having decision-making components, and involving aspects associated with using conservative assumptions indecision making. H.1(a)The inspectors determined that the performance deficiency was more than minor and a finding because it was associated with the Barrier Integrity Cornerstone objective to provide reasonable assurance that physical design barriers protect the public from radionuclide releases caused by accidents or events. The inspectors evaluated the finding using IMC 0609, Appendix A, Attachment 1, Significance Determination of Reactor Inspection Findings for At-Power Situations, using the Phase 1 Worksheet for the Barrier Integrity Cornerstone. Since the inspectors answered no to all four questions in the Containment Barrier column of the Characterization Worksheet for Initiating Events, Mitigating Systems, and Barrier Integrity Cornerstones, the inspectors concluded that the finding was of very low safety significance |
Site: | Monticello |
---|---|
Report | IR 05000263/2010002 Section 1R22 |
Date counted | Mar 31, 2010 (2010Q1) |
Type: | NCV: Green |
cornerstone | Barrier Integrity |
Identified by: | NRC identified |
Inspection Procedure: | IP 71111.22 |
Inspectors (proximate) | K Riemer S Thomas L Haeg S Bakhsh J Bozga M Learn |
CCA | H.13, Consistent Process |
INPO aspect | DM.1 |
' | |
Finding - Monticello - IR 05000263/2010002 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Monticello) @ 2010Q1
Self-Identified List (Monticello)
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||