05000259/FIN-2017002-02
From kanterella
Jump to navigation
Jump to search
Finding | |
|---|---|
| Title | Non -conservative Assumptions in Emergency Drain Capacity Design Review |
| Description | Green . An NRC- identifi ed non- cited violation of 10 CFR 50, Appendix B, Criterion III was identified for the licensee's failure to verify the adequacy of the U nit 1 and 2 diesel building emergency drain pipe to mitigate a postulated internal flood. Specifically, the licensees design review contained non- conservative assumptions. As an immediate corrective action, the licensee reevaluated the potential water accumulation and concluded the diesel generators were still protected. The violation was entered into the licensee's corrective action program as CR 1303737. The performance deficiency was more -than- minor because it was associated with the design control attribute of the Mitigating Systems cornerstone and adversely affected the cornerstone objective to ensure the capability of systems that respond to initiating events to prevent undesirable consequenc es. Specifically, non- conservative assumptions in calculation MDQ00004020110008 resulted in inaccurate conclusions about the capacity of the drain and the resulting water accumulation in the building. The finding was determined to be Green because it represented a deficiency affecting the design of the drain piping, but it maintained its functionality. Functionality was preserved because additional evaluation showed that the resulting water accumulation would not affect any safety related equipment . No cross -cutting aspect was assigned because it was not considered to be reflective of current licensee performance because the performance deficiency occurred more than three years ago . |
| Site: | Browns Ferry |
|---|---|
| Report | IR 05000259/2017002 Section 1R06 |
| Date counted | Jun 30, 2017 (2017Q2) |
| Type: | NCV: Green |
| cornerstone | Mitigating Systems |
| Identified by: | NRC identified |
| Inspection Procedure: | IP 71111.06 |
| Inspectors (proximate) | D Dumbacher T Stephen A Ruh J Dolecki |
| Violation of: | 10 CFR 50 Appendix B 10 CFR 50 Appendix B Criterion III, Design Control |
| INPO aspect | |
| ' | |
Finding - Browns Ferry - IR 05000259/2017002 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Browns Ferry) @ 2017Q2
Self-Identified List (Browns Ferry)
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||