Title | Failure to Identify a Single Point Vulnerability Results in Manual Reactor Scram |
Description | A self-revealed Green finding was identified for the licensees failure to identify a single point vulnerability in accordance with procedure ERAA2004, Revision 1. Specifically, during a site single point vulnerability review of the feedwater system, the licensee failed to identify a single point vulnerability that subsequently resulted in a loss of a feedwater heating string. The loss of the heater string caused a drop in temperature in the reactor of 100 degrees which prompted a manual scrambe initiated by the operators |
Site: | Clinton |
---|---|
Report | IR 05000461/2018001 Section 4OA3 |
Date counted | Mar 31, 2018 (2018Q1) |
Type: | Finding: Green |
cornerstone | Initiating Events |
Identified by: | Self-revealing |
Inspection Procedure: | IP 71153 |
Inspectors (proximate) | W Schaup E Sanchez L Rodriguez C Phillips S Mischke K Stoedter |
INPO aspect | |
' | |
Finding - Clinton - IR 05000461/2018001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|