| Title | Failure to Identify a Single Point Vulnerability Results in Manual Reactor Scram |
| Description | A self-revealed Green finding was identified for the licensees failure to identify a single point vulnerability in accordance with procedure ERAA2004, Revision 1. Specifically, during a site single point vulnerability review of the feedwater system, the licensee failed to identify a single point vulnerability that subsequently resulted in a loss of a feedwater heating string. The loss of the heater string caused a drop in temperature in the reactor of 100 degrees which prompted a manual scrambe initiated by the operators |