Pages that link to "05000395/LER-1983-002, Forwards LER 83-002/03L-0.Detailed Event Analysis Encl"
Jump to navigation
Jump to search
The following pages link to 05000395/LER-1983-002, Forwards LER 83-002/03L-0.Detailed Event Analysis Encl:
Displayed 15 items.
- ML20064M823 (redirect page) (← links)
- 05000395/LER-1983-002 (redirect page) (← links)
- 05000395/LER-1983-005, Forwards LER 83-005/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-004, Forwards LER 83-004/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-002, Forwards Updated LER 83-002/03L-1.Detailed Event Analysis Encl (redirect page) (← links)
- 05000395/LER-1983-001, Updated LER 83-001/01T-1:on 830119,three Refueling Water Storage Tank Level Transmitters Failed High.Caused by Transmitter Base Freezing.Transmitters Thawed.Insulated Encls & Addl Permanent Heat Trace Will Be Installed (← links)
- ML20071B905 (redirect page) (← links)
- 05000395/LER-1983-060, /03L-0:on 831117,investigation Into Previously Submitted LER 83-060 Revealed Four Testable Components Not Tested on Quarterly Basis.Caused by Inadequate Procedure.Test Procedures Revised (← links)
- 05000395/LER-1983-009, Forwards LER 83-009/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-038, Forwards LER 83-038/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-034, Forwards LER 83-034/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-031, Forwards LER 83-031/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-030, Forwards LER 83-030/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-025, Forwards LER 83-025/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-026, Forwards LER 83-026/03L-0 (← links)
- 05000395/LER-1983-021, Forwards LER 83-021/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-023, Forwards LER 83-023/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-022, Forwards LER 83-022/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-024, Forwards LER 83-024/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-020, Forwards LER 83-020/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-019, Forwards LER 83-019/01L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-017, Forwards LER 83-017/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-018, Forwards LER 83-018/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-008, Forwards Updated LER 83-008/03L-1.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-014, Forwards LER 83-014/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-015, Forwards LER 83-015/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-094-03, /03L-0:on 830821,ambient Temp in Svc Water Pump House Exceeded Tech Specs.Caused by Unusually High Outside Air Temp (← links)
- 05000395/LER-1983-085-03, /03L-0:on 830721-24,ambient Temp in Svc Water Pump House Exceeded Tech Spec Limits.Caused by Outside Air Temp Above Average.Mod to Evaluate Need for Installing Cooling Coils Being Processed (← links)
- 05000395/LER-1983-049-03, /03L-0:on 830606,svc Water Booster Pump a Discharge Check valve,XVC-3135A-SW Declared Inoperable Due to Failure to Close on Reverse Flow.Caused by Worn Linkage. Hinge & Key Replaced & Valve Disk Lapped (← links)
- 05000395/LER-1983-043-03, /03L-0:on 830506,while in Mode 5,operations Personnel Stepped Through Maronite Board Fire Barrier.Caused by Personnel Error.Fire Watch Established.Area Posted. Barrier Repaired (← links)
- 05000395/LER-1983-041-01, /01T-0:on 830520,plant Entered Mode 3 W/Train B of Heat Tracing Associated W/Boron Injection Tank Flow Path Deenergized.Caused by Personnel Error & Inadequate Procedure.Panel Energized (← links)
- 05000395/LER-1983-035-03, /03L-0:on 830420,horizontal Fire Barrier Above Svc Water Booster Pump a Found Damaged.Caused by Maint Activities in Immediate Area of Fire Barrier.Damaged Barrier Replaced (← links)
- 05000395/LER-1983-010-03, /03L-0:on 830206,only One Isotopic Iodine Analysis Performed During Power Reduction from 50% to 5%.Caused by Personnel Misinterpreting Power Changes.Chemistry Lab Policy Issued Re Need for Analysis (← links)
- 05000395/LER-1983-007-03, /03L-0:on 830124,9% Discrepancy Found Between Main Control Board & Control Room Evacuation Panel (Crep) Indication for Pressurized Relief Tank Level.Caused by Instrument Drift.Crep Calibr & Returned to Svc (← links)
- 05000395/LER-1983-007, Forwards LER 83-007/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-006-03, /03L-0:on 830113,while in Mode 1,post-accident Hydrogen Analyzer a Declared Inoperable.Caused by Excessive Heat Damage to Wiring & Detector Cell Failing to Adequately Insulate Cover.Cover,Detector Cell & Wiring Replaced (← links)
- 05000395/LER-1983-006, Forwards LER 83-006/03L-0.Detailed Event Analysis Encl (← links)
- 05000395/LER-1983-028-01, /01T-0:on 830406,out-of-tolerance Measurement Found on Undervoltage (UV) Trip Device Between Moving Core & Rolling Bracket.Caused by Mfg Variation of UV Trip Devices. Devices Will Be Replaced (← links)
- 05000395/LER-1983-029-03, /03L-0:on 830320,w/reactor Bldg Purge Initiated, Radiation Monitor RM-A4 Read Higher than Normal Pump RM-A4 & Detector Secured to Change Filter,Leaving Purge Unmonitored for 5 Minutes.No Activity Released During Event (← links)
- 05000395/LER-1983-027-03, /03L-0:on 830318,main Control Board Temp Indication TE-413 for Reactor Coolant Outlet Temp Exhibited Erratic Indications.Caused by Varying Resistance Between Compensated Lead & Low Side Resistance Leg of TE-413 (← links)
- 05000395/LER-1983-011-03, /03L-0:on 830208 & 17,during Mode 1 Operation, Nuclear Sampling Sys Valves 9398 A,B & C Failed to Close. Caused by Limit Switch Failure on One Valve & Crud Buildup on Other Valve Seats.Crud Dislodged.Limit Switches Repaired (← links)
- 05000395/LER-1983-013-03, /03L-0:on 830113 & 19,condensate Storage Tank Level Transmitters LT-3631 & LT-3631A Failed Due to Frozen Instrument Lines.Caused by Temp Sensing Element Not Being Located Per Design Specs.Element Relocated (← links)
- ML20077G500 (← links)
- 05000395/LER-1983-002-03, /03L-0:on 830109,while in Mode 1,main Plant Vent Exhaust Sys Flow Rate Indication Failed Low.Caused by Corrosion on Either Fuse Block or Card Edge Connector of Mixing Amplifier Circuit Board.Circuit Board Cleaned (redirect page) (← links)
- 05000395/LER-1983-002-03, Main Vent Exhaust Sys Flow Rate Indication Failed Low.Caused by Corrosion on Fuse Block or Card Edge Connector of Mixing Amplifier Circuit Board.Circuit Board Components Cleared (redirect page) (← links)
- ML20071B916 (redirect page) (← links)
- 05000395/LER-1983-002, Updated LER 83-002/03L-1:on 830109,main Vent Exhaust Sys Flow Rate Indication Failed Low.Caused by Corrosion on Fuse Block or Card Edge Connector of Mixing Amplifier Circuit Board.Circuit Board Components Cleared (redirect page) (← links)
- 05000395/LER-1983-002-03 (redirect page) (← links)
- ML20064M858 (redirect page) (← links)
- 05000395/LER-1983-002-03, Main Vent Exhaust Sys Flow Rate Indication Failed Low.Caused by Corrosion on Fuse Block or Card Edge Connector of Mixing Amplifier Circuit Board.Circuit Board Components Cleared (redirect page) (← links)
- 05000395/LER-1983-003-03, /03L-0:on 830108 & 20,main Control Board Indication for Steam Generator a Feedwater Flow IFI-477 Failed Low.Caused by High Instrument Cabinet Temp.Power Supply Card Replaced & Recalibr (← links)
- 05000395/LER-1983-091-03, /03L-0:on 830802,while in Mode 1,borated Water Vol of Accumulator a Decreased to 7,354 Gallons.Caused by Valve Leakage in ECCS Check Valve Leakage Detection Sys.Valves Verified in Locked Position.Flange Installed (← links)
- 05000395/LER-1983-075-03, /03L-0:on 830703,emergency Feedwater Valve IFV-3536 to Steam Generator a Tripped Shut on High Flow & Failed to Reset.Caused by Signal Comparator Card Failure. Card Replaced (← links)
- 05000395/LER-1983-074-03, /03L-0:on 830603,during Emergency Diesel Generator a Operability Surveillance Test,Normal 115 Kv Power Supply to Vital Bus Lost & Diesel Generator Output Breaker Tripped Open.Caused by Electrical Surge (← links)
- 05000395/LER-1983-057-03, /03L-0:on 830606,nitrogen Low Pressure Alarm on Low Pressure Accumulator for PORV Received in Control Room. Caused by Valve Position Indicator Lights Not Showing Full Actual Position.Limit Switches Adjusted (← links)
- 05000395/LER-1983-036-03, /03L-0:on 830414,during Performance of Channel Calibr,Pressurizer Safety Valve Position Indication on Valves Failed to Function Properly.Caused by Excessive Current Flow During Contact Closure.Switch Assembly Changed (← links)
- 05000395/LER-1983-033-03, /03L-0:on 830331,while in Mode 5,source Range Detectors N-31 & N-32 Lost for Approx 5 Minutes.Caused by Maint Personnel Error in Placing Trains of Solid State Protection Sys in Wrong Position.Personnel Cautioned (← links)
- 05000395/LER-1983-033, Forwards LER 83-033/03L-0.Detailed Event Analysis Encl (← links)