Finding | |
---|---|
Title | Licensee-Identified Violation |
Description | On May 9, 2013, two workers in the Unit 3 Operations Storage Cell located on the 73 foot elevation of the Primary Auxiliary Building received higher than expected accumulated dose during their work evolution. Subsequent follow-up by the radiation protection staff identified that a drain line in the cell had radiation levels exceeding 100 millirem per hour at 30 centimeters in two locations, but the room was not posted and controlled as a high radiation area, contrary to plant Technical Specification 5.7.1. This issue was documented in their CAP as condition report IP3-2013-02699. |
Site: | Indian Point |
---|---|
Report | IR 05000247/2013004 Section 4OA7 |
Date counted | Sep 30, 2013 (2013Q3) |
Type: | NCV: Green |
cornerstone | Mitigating Systems |
Identified by: | Licensee-identified |
Inspection Procedure: | |
Inspectors (proximate) | J Nicholson J Stewart K Dunham J Schoppy J Furia S Mccarver A Patel J Laughlin A Burritt |
Violation of: | Technical Specification |
INPO aspect | |
' | |
Finding - Indian Point - IR 05000247/2013004 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Finding List (Indian Point) @ 2013Q3