Response to NuScale Topical Report Audit Question Number A-NonLOCA.LTR-16
ML24215A252
Person / Time
Site: 05200050
Issue date: 08/02/2024
From:
NuScale
To:
Office of Nuclear Reactor Regulation
Shared Package
ML24215A000 List: ... further results
References
LO-169995
Download: ML24215A252 (1)


Text

Response to NuScale Topical Report Audit Question Question Number: A-NonLOCA.LTR-16 Receipt Date: 01/15/2024 Question:

Please provide the evaluation used to determine that the PIRT developed for previous NPM is applicable and appropriate for the current submitted NPM.

Response

ER-126485, Rev. 0, NRELAP5 Applicability to NPM-20 Non-LOCA Analysis, Section 4.1 provides the evaluation that the PIRT developed for the previous NPM design (i.e., NPM-160) is applicable to the current NPM design (i.e., NPM-20). ER-126485 has previously been provided in the non-LOCA area of the electronic reading room (eRR) in response to other audit questions. As stated in Section 4.1.2 of ER-126485, the PIRT developed for NPM-160 is not required to be updated for NPM-20 because there are no new additional phenomena identified for NPM-20.

No changes to the SDAA are necessary.