ML24067A124

From kanterella
Revision as of 13:33, 5 October 2024 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Email to Christian Williams: Request for Additional Information Regarding Dresden Relief Request Dated February 23, 2024
ML24067A124
Person / Time
Site: Dresden  Constellation icon.png
Issue date: 03/01/2024
From: Yen-Ju Chen
Storage and Transportation Licensing Branch
To: Williams C
Constellation Nuclear
References
Download: ML24067A124 (1)


Text

From: Yen-Ju Chen To: Williams, Christian D:(Constellation Nuclear)

Cc: Christian Jacobs; John-Chau Nguyen

Subject:

Request for Additional Information for Dresden Exemption Request Date: Friday, March 1, 2024 10:05:00 AM

Dear Mr. Williams:

Per our earlier conversation, the staff is requesting additional information to complete the review of Dresdens exemption request dated February 23, 2024 (ML24054A031). Please provide the following information by the end of business day today, March 1, 2024, in order to support your requested need date of April 18, 2024.

1. For future loading, provide the procedures for handling the dry cask storage system (i.e.,

loading, handling, and transit) that demonstrate that the system is either handled with a single failure proof device such that a drop is considered non-credible or administrative controls are in place to protect the lift height, which include an acceptable analysis that the MPC confinement boundary is maintained. GLs can refer to specific FSAR section and describe how it applies to site specific situations.

In the exemption request, under the technical justification for structural and confinement, Dresden stated that the structural assessment considered the handling operations for the dry cask storage system. Provide the handling procedures to support the justification in the exemption request.

2. Demonstrate that radiation release during a postulated accident is within the regulatory limits.

The analyses in Holtecs Final Safety Analysis Report (FSAR) for accident conditions demonstrate the consequences of accidents challenging the integrity of the confinement barrier and shielding design features should not exceed limits established in 10 CFR 72.106. The analyses in the FSAR also demonstrate that offsite doses during normal operations and anticipated occurrences should not exceed the limits of 10 CFR 72.104.

In the exemption request, under environmental consideration, Dresden states that the confinement boundary maintains its structural integrity during accident conditions.

Demonstrate that the site-specific dose calculations for the postulated release would be within the regulatory limits, e.g., information/calculations from the 72.212 report.

3. Demonstrate that this exemption is otherwise in public interest. Provide site-specific information on why this exemption is needed right now and why it is in the public interest to grant this exemption.

Yen

Yen-Ju Chen Storage and Transportation Licensing Branch Division of Fuel Management U.S. Nuclear Regulatory Commission yen-ju.chen@nrc.gov 301-415-1018