ML21144A237

From kanterella
Revision as of 13:05, 19 January 2022 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
ES-301-4
ML21144A237
Person / Time
Site: Clinton Constellation icon.png
Issue date: 04/13/2021
From: Gregory Roach
Operations Branch III
To:
NRC/RGN-III/DRS/OLB
Roach G
Shared Package
ML20136A302 List:
References
Download: ML21144A237 (1)


Text

ES-301 Simulator Scenario Quality Checklist Form ES-301-4 Facility: CPS Date of Exam: 3/29/2021 Scenario Numbers: 2 / 3 / 4 Operating Test No.:2021.301 QUALITATIVE ATTRIBUTES Initials a b* c*

1. The initial conditions are realistic in that some equipment and/or instrumentation may be out of service, GMR but it does not cue the operators into expected events. f"I.
2. The scenarios consist mostly of related events. /'1 .,.... GMR
3. Each event description consists of the following:
  • the point in the scenario when it is to be initiated
  • the malfunction(s) or conditions that are entered to initiate the event M
  • the symptoms/cues that will be visible to the crew GMR
  • the expected operator actions (by shift position)
  • the event termination point (if applicable)

GMR

4. The events are valid with regard to physics and thermodynamics. M  ?""
5. Sequencing and timing of events is reasonable and allows the examination team to obtain complete evaluation results commensurate with the scenario objectives. M ,- GMR
6. If time compression techniques are used, the scenario summary clearly so indicates.

Operators have sufficient time to carry out expected activities without undue time constraints. M GMR Cues are given.

7. The simulator modeling is not altered. M .,.... GMR
8. The scenarios have been validated. Pursuant to 10 CFR 55.46(d), any open simulator performance deficiencies or deviations from the referenced plant have been evaluated to ensure that functional M GMR fidelity is maintained while running the planned scenarios. 9-
9. Scenarios are new or significantly modified in accordance with Section 0.5 of ES-301. M ,- GMR
10. All individual operator competencies can be evaluated, as verified using Form ES-301-6 (submit the form along with the simulator scenarios). JV'\ ,- GMR
11. The scenario set provides the opportunity for each applicant to be evaluated in each of the applicable GMR rating factors. (Competency rating factors as described on Forms ES-303-1 and ES-303-3.) M

?-

12. Each applicant will be significantly involved in the minimum number of transients and events specified GMR on Form ES-301-5 (submit the form with the simulator scenarios). M
13. Applicants are evaluated on a similar number of preidentilied critical tasks across scenarios, when GMR possible. M
14. The level of difficulty is appropriate to support licensing decisions for each crew position. (vi ,- GMR Target Quantitative Attributes per Scenario (See Section D.5.d) Actual Attributes .. -- --

GMR

1. Malfunctions after EOP entry (1-2) 1/ 1 / 1 /'I "r-
2. Abnormal events (2-4) GMR 4/ 4 /4 ("I  ?--

GMR

3. Major transients (1-2) 1 / 1 /1 f'I 9-
4. EOPs entered/requiring substantive actions (1-2) 2/ 2 /1 GMR

.M 9-'

5. Entry into a contingency EOP with substantive actions 1 per scenario 1 / 1 /1 M GMR set)  ?-
6. Preidentilied critical tasks 2) 2/ 2 /5 M  ?- GMR
  • The facility licensee signature is not applicable for NAC*developed tests.
  1. An independent NRC reviewer initials items in column "c"; chief examiner concurrence is required.