Category:PRELIMINARY NOTIFICATION OF EVENT OR OCCURRENCE (PNO
MONTHYEARPNO-V-86-073, GL Mcchain,In Custody by FBI on Parole Violation,Issued Claims of Evading Security Background Checks for 6 Yrs While Working at Listed Facilities & Knows of Falsified Weld Records.Investigation in Progress1986-10-23023 October 1986 PNO-V-86-073:GL Mcchain,In Custody by FBI on Parole Violation,Issued Claims of Evading Security Background Checks for 6 Yrs While Working at Listed Facilities & Knows of Falsified Weld Records.Investigation in Progress PNO-III-86-034, on 860407,util Announced Plans to Convert Facility to Be Fueled by Natural Gas.Const on Facility Halted on 840716 Because of Financial & Rate Uncertainties. Conversion Phase to Be Completed in 19901986-04-0808 April 1986 PNO-III-86-034:on 860407,util Announced Plans to Convert Facility to Be Fueled by Natural Gas.Const on Facility Halted on 840716 Because of Financial & Rate Uncertainties. Conversion Phase to Be Completed in 1990 PNO-III-82-078, on 820809,licensee Issued Stop Work Order for Ongoing Remedial safety-related Soils Work at Site,After NRC Determination That Work Not Approved by Nrr.Procedures Requiring Written Approval of Work Will Be Developed1982-08-12012 August 1982 PNO-III-82-078:on 820809,licensee Issued Stop Work Order for Ongoing Remedial safety-related Soils Work at Site,After NRC Determination That Work Not Approved by Nrr.Procedures Requiring Written Approval of Work Will Be Developed PNO-III-82-071, on 820729,received Part 21 Rept Via Telcon W/Zack Co Re Documentation Discrepancies for Welds Made to HVAC Components at La Salle & Possibly at Clinton & Midland.Welder of Record May Not Be Actual Welder1982-07-30030 July 1982 PNO-III-82-071:on 820729,received Part 21 Rept Via Telcon W/Zack Co Re Documentation Discrepancies for Welds Made to HVAC Components at La Salle & Possibly at Clinton & Midland.Welder of Record May Not Be Actual Welder PNO-III-82-068, on 820503,allegations from Former Employee of HVAC Contractor Received Re False or Incomplete QA Documentation for HVAC Work at Sites.Special Insp of Zack Co & Facilities Initiated1982-07-22022 July 1982 PNO-III-82-068:on 820503,allegations from Former Employee of HVAC Contractor Received Re False or Incomplete QA Documentation for HVAC Work at Sites.Special Insp of Zack Co & Facilities Initiated PNO-III-80-050, on 800315,two Pipe Fitters Attempting to Find Gas Leak,Broke Hose Coupling Containing Gas Pressure of 40 Psi.Gas Denotated by Activation of two-way Radio.Three Men Received Second & Third Degree Burns Over 15% of Body1980-03-17017 March 1980 PNO-III-80-050:on 800315,two Pipe Fitters Attempting to Find Gas Leak,Broke Hose Coupling Containing Gas Pressure of 40 Psi.Gas Denotated by Activation of two-way Radio.Three Men Received Second & Third Degree Burns Over 15% of Body ML20249A6301978-06-23023 June 1978 PNS-78-028:on 890624,anti-nuclear Demonstration Scheduled During Wk of 780624-25,at Listed facilities.Anti-nuclear Group from Kansas City Plans to Conduct Rally & Picnic at State Recreation Area in Vicinity of Wolf Creek Const Site ML20151X6941977-10-0707 October 1977 PNO-77-177:on 771007,Dow Chemical Co Accidentally Released Chlorine Gas Causing Evacuation of Neighboring Townships Population.Situation Returned to Normal by Midafternoon ML20249B8301976-07-29029 July 1976 PNO-76-133:Consumers Power Co Informed Region III That Errors Were Discovered in Placing Reinforcing Steel Bars at Three Locations in Auxiliary Building at Midland Construction Site.Inspector at Site to Review Problem 1986-04-08
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000329/19860011986-10-28028 October 1986 Insp Repts 50-329/86-01 & 50-330/86-01 on 861015-16.Major Areas Inspected:Licensee Plans for Facility,Matls Licenses & Insp of Remedial Soils Work Areas.All Work to Leave Soils Remedial Work in Safe Condition Satisfactorily Accomplished PNO-V-86-073, GL Mcchain,In Custody by FBI on Parole Violation,Issued Claims of Evading Security Background Checks for 6 Yrs While Working at Listed Facilities & Knows of Falsified Weld Records.Investigation in Progress1986-10-23023 October 1986 PNO-V-86-073:GL Mcchain,In Custody by FBI on Parole Violation,Issued Claims of Evading Security Background Checks for 6 Yrs While Working at Listed Facilities & Knows of Falsified Weld Records.Investigation in Progress PNO-III-86-034, on 860407,util Announced Plans to Convert Facility to Be Fueled by Natural Gas.Const on Facility Halted on 840716 Because of Financial & Rate Uncertainties. Conversion Phase to Be Completed in 19901986-04-0808 April 1986 PNO-III-86-034:on 860407,util Announced Plans to Convert Facility to Be Fueled by Natural Gas.Const on Facility Halted on 840716 Because of Financial & Rate Uncertainties. Conversion Phase to Be Completed in 1990 IR 05000329/20050101985-05-30030 May 1985 Insp Rept 50-456/85-16 on 850329-0510.No Noncompliance or Deviation Noted.Major Areas Inspected:Actions on Previous Insp Items,Preoperational Test Program Implementation & Preoperational Test Procedures Review IR 05000329/20040251985-05-17017 May 1985 Notice of Violation from Insp on 850329-0425 ML20206H8121983-09-14014 September 1983 Rept of Inquiry Q3-83-001 Re Allegation of Improper Welding & Termination of QC Inspector Employment.Inquiry Closed Based Upon Seriousness of Allegation That Kent Terminated Due to Contact W/Bechtel Personnel.Related Documents Encl PNO-III-82-078, on 820809,licensee Issued Stop Work Order for Ongoing Remedial safety-related Soils Work at Site,After NRC Determination That Work Not Approved by Nrr.Procedures Requiring Written Approval of Work Will Be Developed1982-08-12012 August 1982 PNO-III-82-078:on 820809,licensee Issued Stop Work Order for Ongoing Remedial safety-related Soils Work at Site,After NRC Determination That Work Not Approved by Nrr.Procedures Requiring Written Approval of Work Will Be Developed PNO-III-82-071, on 820729,received Part 21 Rept Via Telcon W/Zack Co Re Documentation Discrepancies for Welds Made to HVAC Components at La Salle & Possibly at Clinton & Midland.Welder of Record May Not Be Actual Welder1982-07-30030 July 1982 PNO-III-82-071:on 820729,received Part 21 Rept Via Telcon W/Zack Co Re Documentation Discrepancies for Welds Made to HVAC Components at La Salle & Possibly at Clinton & Midland.Welder of Record May Not Be Actual Welder IR 05000329/19810231982-07-26026 July 1982 IE Insp Repts 50-329/81-23 & 50-330/81-23 on 811201-820630. No Noncompliance Noted.Major Areas Inspected:Exam of Site Conditions & Laydown Areas,Onsite Storage of Matl,Mgt Meetings & Changes in Site Mgt IR 05000329/19820101982-07-22022 July 1982 IE Insp Repts 50-329/82-10 & 50-330/82-10 on 820602-04,30 & 0701.No Noncompliance Noted.Major Areas Inspected:Followup on 10CFR50.55e Items Re Containment Internal Structures Coating Deficiency PNO-III-82-068, on 820503,allegations from Former Employee of HVAC Contractor Received Re False or Incomplete QA Documentation for HVAC Work at Sites.Special Insp of Zack Co & Facilities Initiated1982-07-22022 July 1982 PNO-III-82-068:on 820503,allegations from Former Employee of HVAC Contractor Received Re False or Incomplete QA Documentation for HVAC Work at Sites.Special Insp of Zack Co & Facilities Initiated ML20055B0361982-07-0101 July 1982 Notice of Violation from Insp on 820412-14,21-23 & 29 IR 05000329/19820031982-07-0101 July 1982 IE Insp Repts 50-329/82-03 & 50-330/82-03 on 820412-14, 21-23 & 29.Noncompliance Noted:Failure to Follow Procedures Re Attachment Changes to Drawings & Verification of Design Changes & Inadequate Controls During Excavation IR 05000329/19820121982-06-14014 June 1982 Insp Repts 50-329/82-12 & 50-330/82-12 on 820601-02.No Noncompliance or Deviations Noted.Major Areas Inspected: Preservice Insp Procedures,Work Activities,Nde Personnel Data & Certifications & Previous Insp Findings PNO-III-80-050, on 800315,two Pipe Fitters Attempting to Find Gas Leak,Broke Hose Coupling Containing Gas Pressure of 40 Psi.Gas Denotated by Activation of two-way Radio.Three Men Received Second & Third Degree Burns Over 15% of Body1980-03-17017 March 1980 PNO-III-80-050:on 800315,two Pipe Fitters Attempting to Find Gas Leak,Broke Hose Coupling Containing Gas Pressure of 40 Psi.Gas Denotated by Activation of two-way Radio.Three Men Received Second & Third Degree Burns Over 15% of Body ML20126L8221979-12-0909 December 1979 Notice of Violation from Insp on 781211-790125.Noncompliance Noted Determined to Be Matl False Statement IR 05000329/19780121978-11-14014 November 1978 IE Inspec Repts 50-329/78-12 & 50-330/78-12 on 781024-27 During Which No Items of Noncompliance Were Noted.Major Areas Inspected incl:10CFR50.55(e) Rept Concerning Settlement of Diesel Generator Foundation & Bldg IR 05000329/19780141978-11-0606 November 1978 IE Inspec Repts 50-329/78-14 & 50-330/78-14 on 780910-29 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Examination of Gen Site Condition & Steam Generator & Reactor Vessel Hold Down Bolting ML20062E2901978-11-0303 November 1978 Notice of Violation from Inspec on 780724-0928 IR 05000329/19780131978-11-0303 November 1978 IE Inspec Repts 50-329/78-13 & 50-330/78-13 on 780724-0908 During Which 2 Items of Noncompliance Were Noted:Welds with Unequal Outside Diameters Were Accepted & Safety Related Control Rod Drive Primary Breakers Were Not Well Protected IR 05000329/19780111978-10-26026 October 1978 IE Inspec Repts 50-329/78-11 & 50-330/78-11 on 780926-28 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Incl:Babcock & Wilcox Constr Co Nondestructive Examination Prog Procedures & Personnel Cert IR 05000329/19780101978-10-10010 October 1978 IE Inspec Repts 50-329/78-10 & 50-330/78-10 on 780913-15 During Which No Items of Noncompliance Were Noted.Major Areas Inspected Included:Installation of safety-related Hangers & Restraints IR 05000329/19780091978-09-21021 September 1978 IE Inspec Repts 50-329/78-09 & 50-330/78-09 on 780829-31 During Which 1 Item of Noncompliance Was Noted:Failure to Follow Procedure in Welding Root Pass ML20058A1921978-09-21021 September 1978 Notice of Violation from Inspec on 780829-31 ML20249A6301978-06-23023 June 1978 PNS-78-028:on 890624,anti-nuclear Demonstration Scheduled During Wk of 780624-25,at Listed facilities.Anti-nuclear Group from Kansas City Plans to Conduct Rally & Picnic at State Recreation Area in Vicinity of Wolf Creek Const Site ML20151X6941977-10-0707 October 1977 PNO-77-177:on 771007,Dow Chemical Co Accidentally Released Chlorine Gas Causing Evacuation of Neighboring Townships Population.Situation Returned to Normal by Midafternoon IR 05000330/19770021977-03-15015 March 1977 Const Insp Rept 50-330/77-02 on 770228-0301.Noncompliance Noted:Failure to Rept Bulge Deficiency Per 10CFR50.55(e)(z). Related Info Encl ML20249B8301976-07-29029 July 1976 PNO-76-133:Consumers Power Co Informed Region III That Errors Were Discovered in Placing Reinforcing Steel Bars at Three Locations in Auxiliary Building at Midland Construction Site.Inspector at Site to Review Problem 1986-04-08
[Table view] |
Text
_ __ _ _ _ _ __-
' PRELIMINARY NOTIFICATION de / lay 4 sM ?
. . . . . J' e '
. July 29, 1976 PRELIMINARY NOTIFICATION OF EVENT OR UNUSUAL OCCURRENCE--PNO-76-133 -
This preliminary notification constitutes EARLY notice of an event of POSSIBLE safety or public interest significance. The information
~ ' ' '
- presented is as initially received without verification or evaluation , _ _ , , . .
and is basically all that is known by IE staff on this date.
Facility: Consumers Power. Company, Midland 1 and 2 *
(DN 50-329, and 50-330) Jackson, Michigan
Subject:
CONCRETE WORK HALTED AT MIDLAND; CONSIDERABLE NEWS MEDIA INTEREST LOCALLY Consumers Power Company informed Region III (Chicago) that errors were discovered in placing reinforcing steel bars at three locations in the auxiliary building at its Midland construction site. . Reinforcing steel --.
placement errors have been a repetitive problem at Midland and have been the subject of several Region III inspections and management meetings since March 1976. ,
- l. The errors, involving omission or misplacement of reinforcing steel, i were found through an augmented quality assurance program instituted by Consumers Power Company in late June 1976. These errors were
- identified by Consumers Power inspectors before pouring of concrete, but after normal quality control inspections had failed to identify the problems. As a result, the utility has halted all concrete work involving reinforcing steel. (Concrete work had been halted by the utility in June and on three earlier occasions because of problems associated with the placement of reinforcing steel.)
Ragion III considers this matter to be of importance because of the interest shown by the Midland Atomic Safety and Licensing Board and
- l. Appeals Board in quality assurance matters and because of an earlier Show cause Order issued by the Commission for quality assurance k/
problems at Midland.
A Ragion III inspector is at the site today to review the problem.
'O '
Consumers Power issued'a press release 7/27/76. There has been d considerable news media interest in Michigan.
l
- CONTINUED I
I
,,yvidO ,
9806240282 760729 PDR IS E PNO-76-133 PDR ' '
,, ._ - ._ . . . . . , y Page 2
- PNO-76-133 continued , . . July 29, 1976 1
Region III received notification of this occurrence by telephone frok Consumers Power Company at 10 a.m. 7/27/76. This PN is issued as a result of news media interest which became evident on 7/28/76. The
, State of Michigan has been notified of the matter.
Contact:
RFWarnick, IE x27261 GWRoy, TE 27261 DThompson, IE x27541 Distribution:
Chairman Rowden Commissioner Mason S. J. Chilk, SECY Commissioner Gilinsky C. C. Kammerer, CA G. F. Murphy, JCAE Commissioner Kennedy i
L. V. Gossick, EDO E. Volgenau, OIE J. A. Harris, PA B. C. Rusche, NRR H. K. Shapar, ELD T. J. FcTiernan, AIA m K. R. Chapman, NMSS R. G. Ryan, OSP Transmitted: PBldg9 ; E St 9 ; MNBB 9 A. ; Luge /ff ;
PRELIMINARY NOTIFICATION 4