ML20126B366

From kanterella
Revision as of 12:38, 12 July 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Proposed Tech Specs Consisting of Change Number 167,revising TS Calibration Requirements in Table 4.2.5 to Reflect That No Meaningful Calibration of Startup Range Monitor & IRM Detector Not Fully Inserted
ML20126B366
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 12/15/1992
From:
VERMONT YANKEE NUCLEAR POWER CORP.
To:
Shared Package
ML20126B354 List:
References
NUDOCS 9212220068
Download: ML20126B366 (1)


Text

_ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _- . _ __-_ __ _ _ _ _ _ _ _ _ _ _

VYNPS P

TABLE 4.2.5 MINIMUM TEST AND CALIBRATION FRE00ENCIES CONTROL ROD BLOCK INSTRUMENTATION

$ib

"'E

>$$ Trio Function Functional Test Calibration EO cus Startup Range Monitor N a. Upscale Notes 4 and 6 Note 6 gj@ b. Detector Not Fully Inserted Note 6 NA l

OG Intermediate Range Monitor

$OG a. Upscale Notes 4 and 6 Note 6 2'd b. Downscale Notes 4 and 6 Note 6

c. Detector Not Fully Inserted Note 6 NA f Average Power Range Monitor
a. Upscale (Flow Bias) Notes I and 4 Every Three Months
b. Downscale Notes 1 and 4 Every Three Months Rod Block Monitor
a. Upscale (Flow Bias) Notes 1 and 4 Every Three Months
b. Downscale Notes 1 and 4 Every Three Months Trip System Logic Once/ Operating Cycle Once/ Operating Cycle (Note 3)

High Water Level in Scram Every Three Months Refueling Outage Discharge Volume Amendment No. 106 H 6 59