_ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ _- . _ __-_ __ _ _ _ _ _ _ _ _ _ _

VYNPS P

TABLE 4.2.5 MINIMUM TEST AND CALIBRATION FRE00ENCIES CONTROL ROD BLOCK INSTRUMENTATION

$ib

"'E

>$$ Trio Function Functional Test Calibration EO cus Startup Range Monitor N a. Upscale Notes 4 and 6 Note 6 gj@ b. Detector Not Fully Inserted Note 6 NA l

OG Intermediate Range Monitor

$OG a. Upscale Notes 4 and 6 Note 6 2'd b. Downscale Notes 4 and 6 Note 6

c. Detector Not Fully Inserted Note 6 NA f Average Power Range Monitor
a. Upscale (Flow Bias) Notes I and 4 Every Three Months
b. Downscale Notes 1 and 4 Every Three Months Rod Block Monitor
a. Upscale (Flow Bias) Notes 1 and 4 Every Three Months
b. Downscale Notes 1 and 4 Every Three Months Trip System Logic Once/ Operating Cycle Once/ Operating Cycle (Note 3)

High Water Level in Scram Every Three Months Refueling Outage Discharge Volume Amendment No. 106 H 6 59