November 10, 2003 Mr. William R. Kanda, Vice President - Nuclear FirstEnergy Nuclear Operating Company 10 Center Road P.O. Box 97 Perry, OH 44081

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (RAI) FOR LICENSE AMENDMENT REQUEST (LAR), INCREASE IN MAIN STEAM LINE TURBINE BUILDING HIGH TEMPERATURE TRIP SETPOINT ALLOWABLE VALUE (TAC. NO. MC0342)

Dear Mr. Kanda:

By letter dated August 14, 2003, FirstEnergy Nuclear Operating Company (FENOC), requested approval of a license amendment request (LAR) for the Perry Nuclear Power Plant (PNPP).

The proposed LAR increases the analytical limit and the resulting Technical Specification Allowable Value (AV) related to the setpoint for the main steam line turbine building temperature - high, system isolation function.

During the review, the NRC staff has identified that additional information is needed in order to complete the review. Specific questions are presented in the attached request for additional information (RAI).

The enclosed questions have already been discussed with your staff. In order to accommodate PNPPs needs, please respond to this RAI by December 15, 2003. If you have any questions concerning our review, or additional time is needed to respond to the RAI, please contact me at (301) 415-3154.

Sincerely,

/RA/

Stephen P. Sands, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-440 Enclosure : Request for Additional Information cc w/encl: See next page

November 10, 2003 Mr. William R. Kanda, Vice President - Nuclear FirstEnergy Nuclear Operating Company 10 Center Road P.O. Box 97 Perry, OH 44081

SUBJECT:

REQUEST FOR ADDITIONAL INFORMATION (RAI) FOR LICENSE AMENDMENT REQUEST (LAR), INCREASE IN MAIN STEAM LINE TURBINE BUILDING HIGH TEMPERATURE TRIP SETPOINT ALLOWABLE VALUE (TAC. NO. MC0342)

Dear Mr. Kanda:

By letter dated August 14, 2003, FirstEnergy Nuclear Operating Company (FENOC), requested approval of a license amendment request (LAR) for the Perry Nuclear Power Plant (PNPP).

The proposed LAR increases the analytical limit and the resulting Technical Specification Allowable Value (AV) related to the setpoint for the main steam line turbine building temperature - high, system isolation function.

During the review, the NRC staff has identified that additional information is needed in order to complete the review. Specific questions are presented in the attached request for additional information (RAI).

The enclosed questions have already been discussed with your staff. In order to accommodate PNPPs needs, please respond to this RAI by December 15, 2003. If you have any questions concerning our review, or additional time is needed to respond to the RAI, please contact me at (301) 415-3154.

Sincerely,

/RA/

Stephen P. Sands, Project Manager, Section 2 Project Directorate III Division of Licensing Project Management Office of Nuclear Reactor Regulation Docket No. 50-440

Enclosure:

Request for Additional Information cc w/encl: See next page DISTRIBUTION:

PUBLIC PDIII-2 r/f AMendiola THarris SSands OGC ACRS GGrant, RIII ADAMS Accession Number: ML033090400 OFFICE PM:LPD3-2 LA:LPD3-2 SC:LPD3-2 NAME SSands THarris DPickett for AMendiola DATE 11/07/03 11/07/03 11/10/03 OFFICIAL RECORD COPY

Perry Nuclear Power Plant, Unit 1 cc:

Mary E. OReilly Carol OClaire, Chief, Radiological Branch FirstEnergy Corporation Ohio Emergency Management Agency 76 South Main St. 2855 West Dublin Granville Road Akron, OH 44308 Columbus, OH 43235-7150 Resident Inspectors Office Mayor, Village of Perry U.S. Nuclear Regulatory Commission P.O. Box 100 P.O. Box 331 Perry, OH 44081-0100 Perry, OH 44081-0331 Dennis Clum Regional Administrator, Region III Radiological Assistance Section Supervisor U.S. Nuclear Regulatory Commission Bureau of Radiation Protection 801 Warrenville Road Ohio Department of Health Lisle, IL 60532-4531 P.O. Box 118 Columbus, OH 43266-0118 Sue Hiatt OCRE Interim Representative Zack A. Clayton 8275 Munson DERR Mentor, OH 44060 Ohio Environmental Protection Agency ATTN: Mr. Zack A. Clayton Mr. Vernon K. Higaki P.O. Box 1049 Manager - Regulatory Affairs Columbus, OH 43266-0149 FirstEnergy Nuclear Operating Company Perry Nuclear Power Plant Chairman P.O. Box 97, A210 Perry Township Board of Trustees 10 Center Road 3750 Center Road, Box 65 Perry, OH 44081 Perry, OH 44081 Timothy Rausch, Plant Manager Daniel Z. Fisher FirstEnergy Nuclear Operating Company Transportation Department Perry Nuclear Power Plant Public Utilities Commission P.O. Box 97, SB306 180 East Broad Street Perry, OH 44081 Columbus, OH 43215-3793 Mayor, Village of North Perry Mr. William R. Kanda North Perry Village Hall Vice President - Nuclear, Perry 4778 Lockwood Road FirstEnergy Nuclear Operating Company North Perry Village, OH 44081 Perry Nuclear Power Plant P.O. Box 97, A200 Donna Owens, Director 10 Center Road Ohio Department of Commerce Perry, OH 44081 Division of Industrial Compliance Bureau of Operations & Maintenance 6606 Tussing Road P. O. Box 4009 Reynoldsburg, OH 43068-9009

REQUEST FOR ADDITIONAL INFORMATION PERRY NUCLEAR POWER PLANT (PNPP)

INCREASE IN MAIN STEAM LINE TURBINE BUILDING HIGH TEMPERATURE TRIP SETPOINT ALLOWABLE VALUE The Nuclear Regulatory Commission (NRC) staff has reviewed the August 14, 2003, FENOC submittal regarding changes to the Perry Nuclear Power Plant license amendment request to increase the main steam line turbine building temperature - high, system isolation function, and has the following questions concerning the submittal:

(1) Provide a description of the GOTHIC nodal model (include the GOTHIC version number) used to model the building (volumes, flow paths, active heat removal systems and heat structures, and their initial conditions). Identify the model used for the break flow, the model(s) used for heat transfer to structures, and the model used for flow between volumes. If the GOTHIC jet breakup model is used, provide justification to support its use for this application.

(2) Provide a benchmark of the GOTHIC model to the current COMPARE model using GOTHIC models which closely resemble COMPARE.

(3) Provide electronic copy(ies) of the GOTHIC input deck(s) (*.GTH) for the model used for the LAR. The staff may perform independent, confirmatory analyses with the CONTAIN 2.0 code. In addition, the input deck should provide the full description of the nodal models and the GOTHIC models used for the LAR.