MONTHYEARML24248A0452024-09-0303 September 2024 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report - Kemps Ridley Sea Turtle Collected on 9/3/2024 ML24229A0422024-08-16016 August 2024 NRR E-mail Capture - Acceptance Review - Salem 1 and 2 - Implement Optimized ZIRLO Fuel Rod Cladding ML24229A0432024-08-16016 August 2024 NRR E-mail Capture - Acceptance Review - Salem 1 and 2 - Exemption from 10 CFR 50.46 and 10 CFR 50 Appendix K to Allow the Use of Optimized ZIRLO Fuel Rod Cladding ML24228A1942024-08-14014 August 2024 NRR E-mail Capture - (External_Sender) PSEG Bottom Trawl Sampling - Incidental Take Report and Data Collection Form for a Live - Atlantic Sturgeon 8/14/2024 ML24227A5092024-08-14014 August 2024 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report - Kemps Ridley Sea Turtle Collected on 8/13/2024 ML24219A2472024-07-0909 July 2024 NRR E-mail Capture - (External_Sender) PSEG Bottom Trawl Sampling - Incidental Take Report and Data Collection Form - Shortnose Sturgeon 7/9/2024 ML24123A0522024-05-0101 May 2024 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report - One Deceased Sturgeon 4/30/2024 ML24106A0542024-04-12012 April 2024 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Form - One Alive Atlantic Sturgeon 4/12/2024 ML24101A2192024-04-0909 April 2024 NRR E-mail Capture - (External_Sender) PSEG Bottom Trawl Sampling - Incidental Take Report and Data Collection Form - Atlantic Sturgeon 4/8/24 ML24093A1222024-04-0101 April 2024 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Form - One Atlantic Sturgeon 4/1/2024 ML24075A1862024-03-14014 March 2024 NRR E-mail Capture - (External_Sender) Biological Opinion Gar 2020-02842 - PSEG Salem and Hope Creek Generating Station Annual Incidental Take Report - 2023 ML24060A0492024-02-28028 February 2024 NRR E-mail Capture - Final Exhb RAI for Hope Creek, Salem 1 and 2 Amendment to Modify Exclusion Area Boundary ML24030A8432024-01-30030 January 2024 NRR E-mail Capture - (External_Sender) 2023 PSEG Sturgeon Pit Tag Data ML24016A1612024-01-10010 January 2024 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Forms - Two Atlantic Sturgeon 1/9/2024 ML24002A7222023-12-29029 December 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - 2023 Annual Report - Inspection of the Circulating Water Intake Structure (Cwis) Trash Rack Bars ML24002A7242023-12-28028 December 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Form - Sturgeon 12/28/2023 ML23355A2732023-12-21021 December 2023 NRR E-mail Capture - (External_Sender) PSEG Response to Questions Associated with Supplement to Salem-Hope Creek Eab Reduction LAR ML24002A7252023-12-21021 December 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Shortnose Sturgeon 12/21/23 ML23346A0962023-12-0606 December 2023 NRR E-mail Capture - Reminder - Final Report - Completion of Required Additional Protocol (AP) Information in Accordance with the U.S. - IAEA Treaty Obligations ML23311A0792023-11-0101 November 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report - Atlantic Sturgeon Collected on 10/31/2023 ML23277A0482023-10-0404 October 2023 NRR E-mail Capture - 10/4/2023 Email: Acceptance Review - Hope Creek and Salem 1 and 2 - LAR to Modify Exclusion Area Boundary ML23277A0732023-09-29029 September 2023 NRR E-mail Capture - (External_Sender) 9/29/2023 Email from PSEG: Supplement to Proposed Amendment to PSEG Master Decommissioning Trust Amendment ML23226A0702023-08-11011 August 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Form for Sturgeon Collected on 8/10/2023 ML23226A0732023-08-10010 August 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Submittal of Necropsy Reports Regarding Sea Turtles Collected on 06/12/2022 ML23201A0132023-07-20020 July 2023 NRR E-mail Capture - Acceptance Review - Salem 1 and 2 - Permanent Extension of Type a and Type C Containment Leak Rate Test Frequencies ML23172A0982023-06-21021 June 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report - Kemp'S Ridley Sea Turtle Collected on 06/20/2022 ML23164A2062023-06-13013 June 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report - Kemp'S Ridley Sea Turtle Collected on 06/12/2023 ML23163A0442023-06-0606 June 2023 NRR E-mail Capture - (External_Sender) Biological Opinion GAR-2020-02842; FIN Clip Analysis Facilities ML24250A0572023-06-0606 June 2023 PSEG to NMFS, Request for Sturgeon Fin Clip Analysis Facilities ML23153A1552023-06-0202 June 2023 NRR E-mail Capture - (External_Sender) PSEG Bottom Trawl Sampling - Incidental Take Report and Data Collection Form - Atlantic Sturgeon 6/1/2023 ML23151A6582023-05-31031 May 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Forms Sturgeon 5/30/2023 ML23137A2632023-05-17017 May 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Forms Sturgeon 5/16/2023 ML23135A0102023-05-11011 May 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report Sturgeon 5/11/2023 ML23136B2832023-05-0404 May 2023 NRR E-mail Capture - (External_Sender) PSEG Bottom Trawl Sampling - Incidental Take Report and Data Collection Form - Atlantic Sturgeon 5/3/2023 ML23122A1672023-05-0202 May 2023 NRR E-mail Capture - Acceptance Review - Hope Creek and Salem 1 and 2 - Revise TS to Delete TS Section 5.5 - Meteorological Tower Location ML23122A1982023-05-0202 May 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Forms for Atlantic Sturgeon 5/1/2023 ML23117A2722023-04-17017 April 2023 NRR E-mail Capture - (External_Sender) Salem Generating STATION-INCIDENTAL Take of Atlantic Sturgeon Collected on 04/14/2023 ML23079A0032023-03-17017 March 2023 NRR E-mail Capture - Hope Creek, Salem 1 and 2 - Evacuation Time Estimate Review ML23065A0452023-02-23023 February 2023 NRR E-mail Capture - (External_Sender) Salem & Hope Creek Generating STATIONS-ANNUAL Incidental Take REPORT-STATION & REMP ML23033A0302023-02-0808 February 2023 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report Sturgeon 1/24/2023 ML23010A2882023-01-10010 January 2023 NRR E-mail Capture - (External_Sender) Salem Generating STATION-INCIDENTAL Take of Atlantic Sturgeon Collected on 01/09/2023 ML23003A2412023-01-0303 January 2023 NRR E-mail Capture - Final Nvib RAI - Salem Unit 2 Relief Request S2-I4R-211, Fourth Inservice Inspection (ISI) Interval Limited Examinations ML22357A0102022-12-21021 December 2022 NRR E-mail Capture - Final Nphp RAI - Salem Unit 2 Relief Request S2-I4R-211, Fourth Inservice Inspection (ISI) Interval Limited Examinations ML23003A2402022-12-21021 December 2022 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Form for Atlantic Sturgeon Collected on 12/20/2022 ML23003A2392022-12-20020 December 2022 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report and Data Collection Forms for Atlantic Sturgeons Collected 12/19/2022 ML22333A9022022-11-29029 November 2022 NRR E-mail Capture - Final Iolb RAI - Salem 1 and 2 LAR to Revise TS to Extend Allowed Outage Time for Inoperable EDG ML22291A3702022-10-18018 October 2022 NRR E-mail Capture - Acceptance Review - Salem 2 - Relief Request Associated with the Fourth Inservice Inspection (ISI) Interval Limited Examinations (L-2022-LLR-0066) ML22290A2202022-10-17017 October 2022 NRR E-mail Capture - Final RAI - Salem 1 and 2 LAR to Revise TS to Extend Allowed Outage Time for Inoperable EDG ML22285A1562022-10-12012 October 2022 NRR E-mail Capture - (External_Sender) Salem Generating Station - Incidental Take Report Atlantic Sturgeon 10/11/2022 (Bottom Trawl) ML22280A1302022-10-0707 October 2022 NRR E-mail Capture - (External_Sender) PSEG Bottom Trawl Sampling - Incidental Take Report - Sturgeon 10/06/2022 2024-09-03
[Table view] |
Text
OHara, Timothy From: OHara, Timothy I .
Sent: Saturday, April 10, 2010 8:57 AM To: Modes, Michael; Conte, Richard
Subject:
RE: AF Piping update
- Mike, Thanks for the insights. This will give me some avenues to pursue. I'll be back in touch soon.,
Tim OHara
- Original
Message ----- -
From: Modes, Michael Sent:'Saturday, April 10, 2010 5:06 AM To: OHara, Timothy; Conte, Richard
Subject:
RE: AF Piping update I am going to loose contact with you guys starting Sunday afternoon (no internet until Wednesday evening).
They are clearly planning to use it as-is. His summary indicates they are going to dig up all the pipe, perform a profile by UT thickness measurement, subject it to FEA with some future wear. Here is the first rub ... how do you know the rate of degradation? I assume they are going to try a linear argument. We knew what it was when we put it in the ground, we know what it is now, and the rate of degradation is thus. Not so ... the rate of degradation is very slow to break down the coating and then very fast to corrode the pipe itself. There is nothing linear about this based on my recollection of the ground chemistry. You remember they ran a test loop on their system prior to choosing the material for the piping change they implemented in the plant in the late 90s. Some of the loop samples run on their system failed in a matter of months. That is how corrosive this stuff is.
Don't forget ... this is an artificial island built on the tidal marsh of the Delaware river. The ocean salt line regularly comes up this far in the river at high tide and during drought conditions the salt line threatens the fresh water intakes of the Camden water system up river. The plants are actually giant concrete boats that float on the mud. The sit on piles that never reach the bedrock.
A future wear seems to indicate they are not going to re-wrap the pipe before putting it underground again.
That is okay because the rate of corrosion tends to slow down once you have thick oxide coating developed (rust) because it slows the migration of cations.
Of course we would want to review, in detail, the FEA assumptions they use. Anyone involved in OC remembers the pain these can create. I wonder how quickly we can get Sandia lined up to run a benchmark model. Maybe if we threaten this approach it will give PSEG pause. They would realize that we may come back after-the-fact and seriously question the acceptance of the as-is condition based on our independent FEA. Worth the effort don't you think?
As for the rest of the email. I figured they couldn't redesign the entire system for above ground in that short a time. Heck, you have to missile shield, heat trace, and insulate the whole thing, while designing for all the loads.
From: OHara, Timothyv.
Sent: Friday, April 09, 2010 6:27 PM To: Modes, Michael; Conte, Richard
Subject:
FW: AF Piping update 1/D
Mike & Rich, As usually happens, PSEG seems to be changing their approach on the pipe replacement. Today they told us that there were too many unknowns to procede with an above ground redesign.
They are now going to excavate all of the present piping and UT it. They have engaged SIA to perform an FEA of the system, I believe as a prelude to telling us that they can continue to operate the present system.
The attached file is what they are giving SIA as input to the FEA.
The email below from Len Rajkowski gives their new (today) Code approach. I'm going to need some help from someone on whether this is feasible and whether 10 CFR 50.55a accepts this.
Another concern is that they will, in all likelihood not be able to UT everything and will then attempt to use Guided Wave to determine wall thickness.
Mike, I'd like your opinion on what this sounds like and some guidance on who in NRR should review this approach.
Tim OHara From: Schroeder, Daniel L. [1]
Sent: Friday, April 09, 2010 12:09 PM To: OHara, Timothy
Subject:
FW: AF Piping update From: Rajkowski, Leonard J.
Sent: Friday, April 09, 2010 10:46 AM To: Schroeder, Daniel L.
Cc: Eilola Jr, Edwin; Fricker, Carl J.; Mattingly, William F.; Barnes, James M.
Subject:
AF Piping update Dan, Today, 4/9/10, PSEG commences the complete excavation of AF buried piping between the FHB and the Outer Pen. We are also planning to excavate inside the Fuel Transfer Area. This will allow for a more complete UT of the affected piping, while also preparing for a possible replacement in-kind or modified buried arrangement.
A finite element model is being developed, incorporating the irregular pipe section profile defined by the given ultrasonic thickness measurements (and adjusted for the defined future wear). The given pressure and axial loading will be applied to this model such that the resultant primary membrane and bending stresses in the pipe cross-section may be computed for design analysis.
ASME Code Section III Design Analysis As allowed in ASI\4E Section III ND-3611.3 (2004 Edition, latest approved by the NRC), a more rigorous piping design analysis such as NB-3200 may be used to calculate stresses required to satisfy ND-3 600 requirements. Note that the calculated stresses must be compared to the allowable stresses in ND-3 600. Thus to show acceptance of the degraded piping with a non-uniform pipe wall, the design loadings will be determined using design by analysis methods in NB-3200 (see Task 2). Current ASME Code allowable stresses based on a factor of 3.5 on tensile strength will be used.
2
Qualifications: Structural Integrity (SI) will perform this work in accordance with the SI QA Program, which is in compliance with the requirements of 10CFR50, Appendix B, 10CFR21, and ANSI/ASME NQA-1 -1989, 1994 and meets the intent of applicable portions of ANSIN45.2. The SI implementation of the QA Program has been audited and accepted by many nuclear utilities and clients. SI's Quality Assurance Program is controlled by SI's Quality Assurance Manual Revision 6, dated 12/20/2006 and is implemented in accordance with the applicable SI Quality Procedures.
Any questions, please call me, Leonard J Rajkowski Engineering Director Salem Generating Station (856) 339-5142 The information contained in this e-mail, including any attachment(s), is intended solely for use by the named addressee(s). If you are not the intended recipient, or a person designated as responsible for delivering such messages to the intended recipient, you are not authorized to disclose, copy, distribute or retain this message, in whole or in part, without written authorization from PSEG. This e-mail may contain proprietary, confidential or privileged information. If you have received this message in error, please notify the sender immediately. This notice is included in all e-mail messages leaving PSEG. Thank you for your cooperation.
3