2016 LaSalle County Station Initial License Examination Form ES-401-4
ML17079A513
Person / Time
Site: LaSalle  Constellation icon.png
Issue date: 11/16/2016
From:
NRC/RGN-III
To:
Exelon Generation Co
Shared Package
ML15274A408 List:
References
Download: ML17079A513 (3)


Text

ES-401 Record of Rejected K/As Form ES-401-4 Facility Name: LaSalle Date of Exam:10/17/2016 The BWR Outline Generator program was utilized for initial selection. Used the very next available K/A to generate the replacement K/A, unless otherwise indicated. Poker chips were used for all other cases.

Tier / Randomly Reason for Rejection Group Selected K/A RO 295023 A2.03 The random generation program selected 295023 A2.03 for both the RO T1 G1 Became and SRO section of the exam. Randomly reselected 295023 A2.02 for the Q9 295023 A2.02 RO portion of the exam.

RO 295007 A2.01 The random generation program selected 295007 A2.01 for both the RO T1 G2 Became and SRO section of the exam. Randomly reselected 295007 A2.02 for the Q21 295007 A2.02 RO portion of the exam.

RO 295007 A2.02 The random generation program selected 295007 A2.02. This system was T1 G2 Became also randomly selected for SRO Q83. All systems were not sampled prior Q21 295020 A2.06 to selecting another K/A from the same system. Randomly selected 295020 A2.06 to replace.

RO 206000 A3.02 The random generation program selected 206000 A3.02 which applies to T2 G1 Became HPCI system. LaSalle utilizes a HPCS system in lieu of a HPCI system.

Q30 263000 A1.01 Randomly selected 263000 A1.01 to replace the K/A.

RO 207000 K3.01 The random generation program selected 207000 K3.01 which applies to T2 G1 Became ISO Condenser system. LaSalle does not have an ISO Condenser; Q31 239002 K1.02 therefore, randomly selected 239002 K1.02.

SRO 206000 A2.01 The random generation program selected 206000 A2.01 which applies to T2 G1 Became HPCI system. LaSalle utilizes a HPCS system in lieu of a HPCI system.

Q86 261000 A2.06 Randomly selected 261000 A2.06 to replace the K/A.

RO 2.2.44 The Generic K/A 2.2.44 was selected for both RO T3 and SRO T2 G2.

T3 Became The KA statement is oversampled. The RO Question #69 was randomly Q69 2.2.22 selected from the list of Generic K/As. Generic K/A 2.2.22 was selected.

SRO 2.3.05 The Generic K/A 2.3.05 was selected for both RO T3 and SRO T3. The T3 Became K/A statement is oversampled. The SRO Question #98 was randomly Q98 2.3.04 selected from the list of Generic K/As. Generic K/A 2.3.04 was selected.

SRO 2.1.27 The random generation program selected Generic K/A 2.1.27, which does T3 Became not have a 10 CFR 55.43.b link as required for an SRO Only question.

Q87 2.1.23 From the field of unused Generic K/A statements with a 10 CFR 55.43.b link, randomly selected 2.1.23.

SRO 2.1.28 The random generation program selected Generic K/A 2.1.28, which does T3 Became not have a 10 CFR 55.43.b link as required for SRO Only question. From Q90 2.1.25 the field of unused Generic K/A statements with a 10 CFR 55.43.b link, randomly selected 2.1.25.

SRO 214000 A2.01 The random generation program selected 214000 A2.01. This system was T2 G2 Became also randomly selected for RO Q56. All systems were not sampled prior to Q91 201006 A2.01 selecting another K/A from the same system. Randomly selected 201006 A2.01 to replace.

RO 295036 K1.01 The random generation program selected 295036 K1.01. This system was T1 G2 Became also randomly selected for SRO Q85. All systems were not sampled prior Q26 295010 K1.03 to selecting another K/A from the same system. Randomly selected 295010 K1.03 to replace.

ES-401, Page 44 of 50

ES-401 Record of Rejected K/As Form ES-401-4 RO 295027 K2.02 The randomly selected 295027 K2.02 applies to Mark III containment.

T1 G1 Became LaSalles containment is a Mark II; therefore, KA 295027 K2.02 does not Q13 295019 K2.02 apply. 295019 K2.02 was randomly selected from the KAs in T1 G1 that had not been sampled.

RO 295032 K2.06 The randomly selected 295032 K2.06 was previously used on LaSalles T1 G2 Became 13-1 class NRC Exam. Randomly selected another K2 for replacement.

Q23 295032 K2.05 K2.05 was selected as a replacement.

RO 295024 K1.02 The randomly selected 295024 K1.02 applies to Mark III containment.

T1 G1 Became LaSalles containment is a Mark II; therefore, KA 295024 K1.02 does not Q10 295024 K1.01 apply. 295024 K1.01 was selected from the remaining K1s to replace this KA.

RO 295030 A1.04 The randomly selected 295030 A1.04 applies to Mark III containment.

T1 G1 Became LaSalles containment is a Mark II and therefore this KA does not apply.

Q15 295030 A1.01 295030 A1.01 was selected from the remaining A1s to replace this KA.

RO 256000 K3.05 The randomly selected 256000 K3.05 applies to HPCI system. LaSalle T2 G2 Became station does not have a HPCI system. Randomly selected another K3 from Q61 256000 K3.08 256000. 256000 K3.08 was selected as a replacement.

RO 290001 A4.04 The randomly selected 290001 A4.04 applies to Auxiliary Building Temp T2 G2 Became Monitoring in the Control Room. LaSalle station does not have that ability.

Q65 290001 A4.02 Randomly selected another A2 from 290001. A4.02 was selected as a replacement.

RO 214000 K3.02 The randomly selected 214000 K3.02 applies to RRCS. LaSalle station T2 G2 Became does not have RRCS. Randomly selected another K3 from 214000. K3.01 Q56 214000 K3.01 was selected as a replacement.

RO 259002 K5.08 The randomly selected 259002 K5.08 applied to FWCI. LaSalle station T2 G1 Became does not have FWCI. Randomly selected another K5 from 259002. K5.07 Q44 259002 K5.07 was selected as a replacement.

RO 211000 K6.04 The randomly selected 211000 K6.04 applies to the effect a loss of Core T2 G1 Became Spray on SLC. At LaSalle station the SLC and Core Spray systems are not Q34 211000 K6.03 directly related. Randomly selected another K6 from 211000. K6.03 was selected as a replacement.

RO 300000 K2.02 The randomly selected 300000 K2.02 applies to Emergency Air T2 G1 Became Compressors. LaSalle station does not have Emergency Air Compressors.

Q51 300000 K2.01 Randomly selected another K2 from 300000. K2.01 was selected as a replacement.

RO 262001 A1.04 Unable to develop 3 credible distractors for the randomly selected 262001 T2 G1 Became A1.04. Randomly selected another A1 from 262001. 262001 A1.03 was Q47 262001 A1.03 selected as a replacement.

RO 201001 A1.09 The randomly selected 201001 A1.09 overlapped with an abnormal event T2 G2 Became on the 2016 ILT Certification exam, scenario number 3. Randomly Q54 201001 A1.07 selected another A1 from 201001. 201001 A1.07 was selected as a replacement.

SRO 2.3.04 The random generation program selected Generic K/A 2.3.04 from T3 Became Category 3, Radiation Control. Per the Chief examiners request, to ensure Q98 2.1.07 2 topics from Category 1, randomly selected another K/A statement from category 1 of the Generic K/As, Conduct of Operations. 2.1.07 was selected as a replacement.

ES-401, Page 44 of 50

ES-401 Record of Rejected K/As Form ES-401-4 RO 239002 A2.05 The randomly selected 239002 A2.05 applied to the impact of low RPV T2 Became pressure on SRVs. Unable to write a question with three plausible Q43 239002 A2.04 distractors. Randomly selected another A2 from 239002. 239002 A2.04 was selected as a replacement.

SRO 201006 A2.01 The randomly selected 201006 A2.01 applied to the RWM power supply.

T2 Became LaSalle Station does not have a standalone RWM; instead, the RWM Q91 201006 A2.05 function is included in the RCMS system. . Randomly selected another A2 from 201006. 201006 A2.05 was selected as a replacement.

ES-401, Page 44 of 50