Facility Comments on Draft Facility-Developed Exam (Written) (Folder 2)
ML17186A237
Person / Time
Site: Hope Creek PSEG icon.png
Issue date: 07/28/2016
From:
Public Service Enterprise Group
To: Todd Fish
Operations Branch I
Shared Package
ML15308A608 List:
References
TAC U01925
Download: ML17186A237 (6)


Text

ES-401 Written Examination Review Worksheet Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

Q# LOK LOD (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #I Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward KIA Only 1 F 2 B s 2 F 2 N s 3 F 2 B s 4 F 3 M s 5 H 3 B s 6 F 3 B s 7 H 3 M E Include picture of MCR controller 8 H 3 B s 9 H 4 B s 10 H 3 N s 11 H 3 B s 12 F 3 N s 13 H 3 N s 14 H 2 B s 15 H 3 M E Change correct answer to B due to bypass which is procedurally installed 16 H 2 B s 17 H 3 B s Page 1

ES-401 2 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

LOK LOO Q# (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward KIA Only Change reactor power to 9% to comply with station procedures.

18 H 3 B E Mode switch cannot be in startup at 10% per procedures.

H 3 N E Change stem to say valve failed closed instead of bad operator 19 action.

20 H 3 B s 21 H 2 N s 22 H 3 B s 23 F 3 B s 24 F 2 B s 25 F 2 M s 26 F 3 N s 27 H 3 B s 28 F 3 B s 29 H 3 B s 30 H 2 B s 31 F 3 N s 32 H 3 N s 33 F 3 B s 34 H 3 N E Adjust stem for increased rad indications on all 4 MSLs.

35 H 2 B s 36 H 3 M s 37 F 2 B s Page 2

ES-401 2 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

LOK LOO Q# (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #/ Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward KIA Only 38 F 3 B s 39 F 3 B s 40 F 3 M s 41 F 2 B s 42 H 3 B E Add "normal electrical line up" to stem 43 H 3 B s 44 F 3 N s 45 F 3 N s 46 H 3 B s 47 F 3 B s 48 F 2 B s 49 H 3 B s 50 F 3 N s 51 H 3 B s 52 H 3 B E Change stem from "equipment" to "floor" drain.

53 H 3 B s 54 F 2 M s Modify stem to say "electrical transient caused a generator 55 H 3 N E regulation protection relay actuation" instead of listing alarms received.

56 H 3 M s 57 F 3 B s Page 3

ES-401 2 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

LOK LOO Q# (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #I Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward KIA Only 58 H 4 B s 59 H 4 B s 60 H 3 B s 61 F 3 B s 62 F 3 B s 63 H 3 M s 64 H 3 N s 65 H 3 B s 66 F 3 N s 67 F 2 N s 68 F 3 B s 69 F 2 N s 70 H 3 B s 71 H 3 N E Change "steam isolation dampers" to "back draft dampers" 72 F 3 N E Change "ATWAS" to "ATWS" 73 F 3 N E Include elevation numbers for each location.

74 F 2 M s 75 F 2 M s 76 H 3 B E Include procedure numbers.

77 H 3 B s 78 H 3 B s Page4

ES-401 2 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

LOK LOO Q# (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #I Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward KIA Only 79 H 3 M s 80 H 3 M s 81 H 3 M s 82 H 2 B s 83 H 3 B s 84 H 3 N s 85 H 3 N s 86 H 3 N s 87 H 3 B s Remove "after any associated LCO time expires" from stem.

88 F 3 B E 89 H 3 B s 90 H 2 B E In answer A.) change "IRM trip system" to "RPS trip system" 91 H 3 N s 92 H 4 N s 93 H 3 M s 94 F 2 B s 95 F 3 N s 96 F 3 B s 97 H 3 N s 98 H 3 B E Identify the function of the transmitter.

Page 5

ES-401 2 Form ES-401-9

1. 2. 3. Psychometric Flaws 4. Job Content Flaws 5. Other 6. 7. 8.

LOK LOD Q# (F/H) (1-5) Stem Cues T/F Cred. Partial Job- Minutia #I Back- Q= SRO B/M/N U/E/S Explanation Focus Dist. Link units ward KIA Only 99 H 3 N s 100 F 2 B s Page 6