ML071780595

From kanterella
Revision as of 09:28, 23 October 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
2007/06/20-Entergy's Response in Opposition to New England Coalition'S Motion to Extend Time
ML071780595
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 06/20/2007
From: Travieso-Diaz M F
Entergy Nuclear Operations, Entergy Nuclear Vermont Yankee, Pillsbury, Winthrop, Shaw, Pittman, LLP
To:
Atomic Safety and Licensing Board Panel
SECY RAS
References
50-271-LR, ASLBP 06-849-03-LR, RAS 13803
Download: ML071780595 (18)


Text

13-08cop June 20, 2007 UNITED STATES OF AMERICA DONCKEE NUCLEAR REGULATORY COMMISSION June 20,2007 (11:19am)Before the Atomic Safety and Licensing Board OFFICE OF SECRETARY RULEMAKINGS AND In te Mater f )ADJUDICATIONS STAFF Entergy Nuclear Vermont Yankee, LLC ) Docket No. 50-271-LR and Entergy Nuclear Operations, Inc. ASLBP No. 06-849-03-,LR (Vermont Yankee Nuclear Power Station))ENTERGY'S RESPONSE IN OPPOSITION TO NEW ENGLAND COALITION'S MOTION TO EXTEND TIME Pursuant to 10 C.F.R. §2.323(c) and the directive of the Atomic Safety and.Licensing Board ("Board"), see Order (Setting Deadline for Answers to NEC Motion to Extend Time)dated June 19, 2007, Applicants Entergy Nuclear Vermont Yankee, LLC and Entergy Nuclear Operations, Inc. (collectively "Entergy")

provide this Response in opposition to New England Coalition, Inc. ("NEC")'s "Motion to Extend Time for NEC's Opposition to Entergy's Motion for Summary Disposition of New England Coalition's Contention 4 (Flow Accelerated Corrosion")

("NEC Motion").

NEC's motion is unsupported and should be denied.NEC seeks a twenty day extension, beyond the twenty days allowed by 10 C.F.R. §2.1 205(b), to respond to Entergy's Motion for Summary Disposition of New England Coalition's Contention 4 (Flow Accelerated Corrosion)

("Entergy's Sumnma ry Disposition Motion"), filed on June 5, 2007.1 NEC claims it needs this additional time for two reasons: (1) because NEC's consultants need additional time to review "numerous" documents relevant to NEC Contention 4 that Entergy produced as part of its Seventh Supplemental Disclosure, on June 7, 2007; and (2) because NEC's consultants "are hindered by difficulties The requested period includes one week of vacation that NEC Counsel intends to take.

locating information among the large volume of documents Entergy has produced to NEC as non-text-searchable electronic image files." NEC Motion at 1-2. Neither alleged reason is valid.Entergy produced only on document relevant to NEC Contention 4 as part of its June 7, 2007 Supplemental Disclosure:

Dr. Jeffrey Horowitz's four-page "Summary of Observations During VY Site Visit" dated May 29, 2007.2 That document had already been provided to NEC, since it was Exhibit 3 to ilie "Joint Declaration of Jeffrey S. Horowitz and James C. Fitzpatrick in Support of Entergy's Motion for Summary Disposition~of NEC Contention 4", dated May 31, 2007 and was included with Enitergy's Summary Disposition Motion. It taxes credulity to' assert, as NEC does, that it needs a total of forty days to review a single, self-explanatory four-page document.

3 NEC's claim regarding "the large volume of documents" relevant to NEC Contention 4 that it allegedly needs to review is also grossly exaggerated.

Entergy has produced a total of 190 documents relevant to NEC Contention 4 since the contention was admitted.4 See Exhibit 1 hereto. The first 130 of those documents (two-thirds of them), were produced with the initial disclosures on October 23, 2006, almost eight months ago. Id. The next 5 1 documents were 2 This four page document is at Bates-stamped pages NEC044876

-NEC044880 of Entergy's June 7, 2007 supplemental disclosure.

3' To the extent that NEC claims it needs to review the references cited in Dr. Horowitz's Summary of Observations During VY Site Visit (see NEC Motion at 2), all but one of those references were provided to NEC during disclosure, as follows: Ref. 1: produced on October 23, 2006 (Bates Nos. NEC005984

-NEC006012);

Ref. 2: produced on Dec. 7, 2006'(Bates Nos. NEC024377

-NEC024381);

Ref. 3: produced on Dec. 7,2006 (Bates Nos.NEC018576 -NEC018617);

Ref. 4: produced on May 3, 2007 (Bates Nos. NEC038505

-NEC038512);

Ref. 5: produced on May 3, 2007 (Bates Nos. NEC038416

-NEC038418);

Ref. 6: produced on May 3, 2007 (Bates Nos.NEC038462 -NEC038504);

Ref.7: Produced on May 3, 2007 (Bates Nos. NEC038513 -NEC038555);

Ref. 8: produced on May 3,2007 (Bates Nos. NEC038450

-NEC038461);

Ref. 9: identified on proprietary log, Dec. 7, 2006; Ref. 10: produced on May 3, 2007 (Bates Nos. NEC038419

-NEC038449);

Ref. 11: produced on May 3, 2006 (Bates Nos. NEC038398

-NEC0384 15); Ref. 12: produced on Dec. 7, 2006 (Bates Nos. NEC008692

-NEC008877);

Ref. 14: produced on Dec. 7, 2006 (Bates Nos. NEC017817

-NEC017850).

Ref. 13, a twelve-page Entergy Nuclear Northeast procedure on component scanning and gridding, was mistakenly not produced previously but was e-mailed today.NEC does not need to review these documents to respond to Entergy's Summary Disposition Motion, but assuming arguendo that it does, it has had all but one 12-page document for some time.4 The reference to "4 gigabytes of documents," see NEC Motion at 2, refers to all documents on NEC Contentions 1-4 provided in discovery by Entergy. The vast majority of those documents are irrelevant to NEC Contention

4.2 prdduced

in the first supplemental discovery on December 7, 2006, over six months ago. Id. In othei words, NEC has had 181 out of the 190 documents relevant to Contention 4 since last year, and has had that much time to review all butrnine of the discovery documents relevant to the contention.

Surely, NEC could have. easily ieviewed those documents had it applied itself to the task.* Of the remaining nine documents, eight were produced on May 3, 2007.5 They total a combined one hundred and sixty three (I163)'pages, and have. been available to NEC for a month atid'a half. Id. As previously stated, Entergy's supplemental disclosure on June 7, 2007 provided only one additional documrent relevant to Contention 4 -the above-mentioned four page '"Summary of Observations During VY Site Visit." Thus, NEC aiid its consultants do not*have -a "large volume" of documents to revie'w -they have had to review only nin documents relevant to Contention 4 this entire year, totaling well under 170 pages. Such a modest review burden cannot credibly be the basis for seeking an extension of time.Moreover, if at any point since October 2006 NEC had experienced difficulty reviewing' or locating a particular document or documents, it could have asked Entergy for assistance or, if such help was unavailing, have sought the Bo ard's intervention.

6 NEC has failed to do so until yesterday's motion, which should be denied as untimely as well as for lacking basis because under 10 C.F.R. § 2.323 (a) a motion "must be made no later than ten (10) days after the occurrence or circumstance from which the motion arises." If NEC was unhappy with the SThese eight documents are Bates-stamped as pages NEC038398 through NEC038561 in Entergy's May 3, 2007 disclosure.

6 For its Initial Disclosures on October 23, 2006, and all supplemental disclosures since, Entergy has used a standard discovery management software, Summation Blaze, to provide copies of relevant documents to NEC.This software produces the documents on compact disk in image format so that each page may contain a bates-stamp number and conform to the original.

It also provides a searchable index of the titles of the documents on each CD, from which each document may be accessed.

All CDs that contain discovery documents for NEC Contentions 2-4 include such an index. NEC has received the disclosed documents in this format for the last eight months, but has never complained until Entergy's Summary Disposition Motion was filed.3 document production format that Entergy has used from the incdption of this proceeding, it should have raised this -issue ten days after the initial disclosures

-i.e., in early November 2006.~In sumniary, NEC's Motion strongly suggests that NEC simply made no attempt to even look at any of Entergy's disclosures with respect to NEC Contention 4 until it received Entergy's Summary Disposition Motion. Any difficulties NEC may be encountering are, therefore, of its own making.For the above described reasons NEC's MotioA is lacking in merit and should be denied.Respectfully Submitted, David R., Lewis Matias F. Travieso-Diaz PILLSBURY.

WINTHROP SHAW PITT MAN LLP'2300 N Street, N.W.Washington, DC 20037-1128 Tel. (202) 663-8000 Counsel for Entergy Dated: June 20, 2007 7' NEC's justification for its alleged difficulties

-that the documents produced by Entergy are not fully searchable

-is hardly a justification.

The NRC regulations do not require the production of documents in fully searchable form. Moreover, given the small number of documents and pages involved, no "full search" capability would be necessary.

Careful reading of the documents would suffice.4

.11-UNITED STATES OF AMIERICA NUCLEAR REGULATORY COMMISSION Before the Atomic Safety and Licensing Board In the Matter of'Entergy Nuclear Vermont Yankee, LLC and.Entergy Nuclear Operations, Inc.)Docket No. 50-271 -LR ASLBP No. 06-849-03-LR (Vermont Yankee Nuclear Power Station))CERTIFICATE OF SERVICE I hereby certify that copies of "Entergy's Response in Opposition to New England Coalition's Motion to Extend Time," dated June 20, 2007, were served on the persons listed below by deposit in the U.S. Mail, first class, postage prepaid, or with respect to Judge Elleman by overnight mail, and where indicated by an asterisk by electronic mail, this 20thý day of June, 2007.*Administrative Judge Alex S. Karlin, Esq., Chairman Atomic Safety and Licensing Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 ask2P~nrc.

gov*Administrative Judge Dr. Thomas S. Elleman Atomic Safety and Licensing Board 5207 Creedmoor Road, #10 1, Raleigh, NC 27612.tseP~nrc.gov; elleman(~eos.ncsu.edu

  • Administrative Judge Dr. Richard E: Wardwell Atomic Safety and Licensing Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 rewP~nre.

gov*Secretary Att'n: Rulemakings and Adjudications Staff Mail Stop 0-16 Cl U.S. Nuclear Regulatory Commission Washington, D.C. 20555-000 1 secv(~nrc.pgov , hearingdocket~nrc.gov Office of Commission Appellate Adjudication Mail Stop 0-16 Cl U.S. Nuclear Regulatory Commission Washington, D.C. 20555-000 1*Mitzi A. Young, Esq.*Mary C. Baty, Esq.Office of the General Counsel Mail Stop 0-15 D21 U.S. Nuclear Regulatory,Commission Washington, D.C. 20555-0001 mavanrc. gov;mcb 1 ~nrc. gov*Anthony Z. Roisman, Esq.National Legal S cholars Law Firm 84 East Thetford Road Lyme, NH 03768 aroismana~nationallegpalscholars.com Atomic Safety and Licensing Board Mail Stop T-3 F23 U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001

  • Sarah Hofmnann, Esq.Director of Public Advocacy Department of Public Service 112 State Street -Drawer 20 Montpelier, VT 05620-260 1 Sarah.bofmann(a-state.vt.u§
  • Ronald A. Shems, Esq.*Karen Tyler, Esq.Shems, Dunkiel, Kassel & Saunders, PLLC 91 College Street Burlington; VT 05401 rshems(@,sdkslaw.com ktvler(@sdkslaw.com
  • Marcia Carpentier, Esq.Law Clerk.Atomic Safety and Licensing Board Panel Mail Stop: T-3F23 U.S. Nuclear Regulatory Commission Washington, DC 20555-000 1 mxc7P~nrc.gov
  • Peter C. L. Roth, Esq.Senior Assistant Attorney General State of New Hampshire Office of the Attorney'Gdtieral 33 Capitol Street Concord., NH 03301 Peter.Roth(@doj .nh.govýA 4^-ft r P'1C-Mvatias F. Travieso-DiA 2

M Exhibit I -Documents Produced for Contention NEC-4 (all productions)

Doc. No.1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Prodno Bates Range Document Title NECO01016 NECO01016

-NECO01017 Email re Vermont License Renewal FAC question NECO01iO18 NECO01018B-NECO01019 Email re Vermont License Renewal FAC question NECO01020 NECO01020

-NECO01022 Email re Vermont License Renewal FAC question NECO01023 NECO01023

-NEC001024 Email re FAC Sample Expansion Issue NECO01025 NECO01025

-NECO01025 FAC Sample Expansion Issue NECO01026 NECO01026

-NECO01028 Email re Vermnont Licens-e Renewa~l FAC question NECO01029 NECO01029

-NECO01030 Email re FAC Program information NECO01031 NECO01031

-NECO01070 Review and Approval Tracking Form re Program for Implementing IFAC Inspection Program NECO01071 NECO01 071 -NECO01099 Procedure re Flow Accelerated Corrosion Program, Rev. 1 NECOOI 100 NECOOI100-NECO01 110 Input to NEC Contention 4 -Presentation on Flow Acceleated Corosion NECOOl 130 NECOOl 130 -NECOOl 130 Email forwarding VY Appendix B NECOO1 131 NECOOl 131 -NEC001254 Appendix B -VY License Renewal Application Tehnical Information re aging management program NECO03071 NECO03071

-NEC003072 License Renewal Application Technical Information Undated draft document related to Flow-Accelerated Corrosion

/ Program Description NEC003073 NEC003073

-NEC003074 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NEC003075 NEC003075

-NEC003076 License Renewal Application Technical Information Undated draft Flow-Accelerated Corrosion!

Program Description CD NEC CD- iInitial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-I Initial Disclosure NEC CD-I Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure Production Date 10/23/20096 10/23/2006 10/2312006 10/23/2006-10/23/i006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006

-10/ 23/2006 10/23/2006 Docid 00O1 554 LR001555 LROO11556 LROO 1557 LROO1 558 LR001559 LR001560 LROO1 561 LR001564 LROO1565 LR001592 LR001593 LR001779 LROO1 780 LR00.1781 LR001782 LROO1 783 NEC003077 NEC003077

-NEC003078 NEC003079 NEC003079

-NECO03080 License Renewal Application Technical Information NEC- CD-i Initial Disclosure Undated draft FlowAccelerated

/ Program Description License Renewal Application Technical Information NEC CD-i Initial Disclosure Undated draft Flow-Accelerated Corrosion!

Program Description 17 6/2012007 Exhibit 1 -Documents Produced.

for Contention NEC-4 (all productions) 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 NECO03081 NECO03081

-NEC003082 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NEC003083 NEC003083

-NECO03084 License Renewal Application Technical Information

-Undated draft Flow-Accelerated CorrosionI Program Description NEC003085 NEC003085

-NECO03087 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NECO03088 NECO03088

-NEC003089 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NECO03090 NECO03090

-NECO03091 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NEC003092 NEC003092

-NEC003093 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NEC003094 NEC003094

-NEC003095 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NEC003096 NEC003096

-NEC003097 License Renewal Application Technical Information Undated draft Flow-Accelerated Corrosion/

Program Description NEC003098 NEC003098

-NEC003099 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NECO03100 NECO03100

-NECO03102 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NECO03103 NECO03103

-NECO03105 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NECO03106 NECO03106

-NECO03108 License Renewal Application Technical Information Undated draft Flow-Accelerated CorrosionI Program Description NECO03109 NECO03109

-NECO031 10 License Renewal Application Technical Information Undated draft Flow-Accelerated Corrosion Program IDecember 2006 hand written on draft.NECO0321 1 NECO03211I

-NEC003225 WYNPS LR Project Evaluation Results NEC004213 NEC004213

-NEC004219.

LR Project Evaluation Results NEC CD-i Initial Disclosure NEC CD-i InitialI Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-I Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosur e NEC CD-i Initial Disclosure 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 LROO1784 LROO1 785 LROO1786 LROO1 787 LROO1 788 LROO1 789 LROO1 790 LR001791 LROO1 792 LRO01793* LR001794 LROO1 795 LR001796 LR00 1813 LR001820 6/20/2007 Exhibit I -Documents Produced for Contention NEC-4 (all productions) 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 NEC004220 NECO04472 NEC004473 NEC004689 NECO04741 NEC004769 NEC004770 NEC004771 NEC004772 NECO04785 NECO04801 NECO04816 NECO04824 NEC004825 NEC004826 NEC004828 NEC004829 NEC004881 NEC004914 NECO05050 NECO04220

-NEC004222 LR Project Aging Management Program Evaluation NEC CD-i Initial Disclosure Results- Corrective Action Program NECO04472

-NEC004472 LR Application FAC Questions asked during NRC Audit NECO04473

-NEC004688 Feedwater Pump Room NECO04689

-NECO04740 Department Procedure 0072 Original DP 0072 Structural Evaluation Of Thinned Walled Piping Components NECO04741

-NEC004768 Procedure Cancellation DP 4023 Piping Flow.Accelerated Corrosion

-NECO04769

-NEC004769 WY Keyword'Search 1999-01701 for Feedwater Heaters NEC004770

-NEC004770 Keyword Search CR-V1Y-2002-02496

& CR-VTY-2002-02568 for Extraction Steam NEC004771

-NEC004771 Quarterly trend CR-VTY-2002-02568 for Extraction Steam NECO04772

-NEC004784 LR Project Aging Management Program Evaluation Results NECO04785

-NECO04800 LR Project Aging Management Program Evaluation Results NECO04801

-NEC004815 LR Project Aging Management Program Evaluation Results NECO04816

-NEC004823 LR Project Aging Management Program Evaluation Results NEC004824

-NEC004824 LR Project Operating Experience Review Report NEC004825

-NEC004825 LR Project Operating Experience Review Report NEC004826

-NEC004827 LR Project Operating Experience Review Report NEC004828

-NEC004828 Operating Experience Review Report, LRPD-05;Rev. 0 -Flow Accelerated Corrosion Program NEC004829

-NEC004880 Procedure re Structural Evaluation of Thinned Wall Piping Components DP0072 Original LPC 1 NEC004881

-NECO04913 Piping Flow Accelerated Corrosion Inspection Program -FAC Susceptible Piping Identiflation NEC004914

-NEC005049 Piping Flow Accelerated Corrosion Inspection Program PP 7028 Original LPC-1 NECO05050

-NEC005055 Aging Management Program Evaluation Results;Flow Accelerated Corrosion Program; LRPD-02, Rev. 0 NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-I Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-I Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-I Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 1 ~0/23/2b06 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 I10/23/2006 LROO1 821 LROO1913 LROO1919 LROO1 921 LROO1 922 LROO1 923 LROO1 924 LR001925 LROO1 927 LROO1 928 LR001929 LROO1 930 LROO1 931 LROO1 932 LROO1 933 LROO1 934 LROO1i935 LROO1 936 LR001937 LROO1 938 6/20/2007 Exhibit I -Documents Produced.

for Contention NEC-4 (all productions) 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 NEC005056 NECO05056

-NEC005058 Aging management Program Evaluation Results;LRPD-02, Rev. 0 NEC005059 NEC005059

-NEC005064.

Aging Management Program Evaluation Results;Flow Accelerated Corrosion Program, LRPD-02, Rev. 1 NEC005065 NEC005065

-NEC005067 Aging Management Program Evaluation Results, LRPD-02, Rev. 1 NEC005068 NEC005068

-NEC005073 Aging Management Program Evaluation Results;Flow Accelerated Corrosion Program, LRPD-02, Rev. 1 NEC005074 NEC005074

-NEC005076 Aging Management Program Evaluation Results LRPD-02, Rev. 1 NEC005077 NEC005077

-NEC005215 Piping Flow Accelerated Corrosion Inspection Program PP 7028 LPC-1 NEC005216 NEC005216

-NEC005220 Program Owner Interview Results NEC005221 NEC005221

-NEC005238 Quality Assurance Evaluation of Engineering Programs NEC005239 NEC005239

-NEC005239 Memorandum re 2002 Refueling Outage Piping Flow Accelerated Corrosion Inspection Summary NEC005240 NEC005240

-NEC005241 Operating Experience Review Report, Flow Accelerated Corrosion Program, LRPD-05, Rev. 0 NEC005242 NEC005242

-NEC005243 Operating Experience Review Report, Flow Accelerated Corrosion Program, LRPD-05, Rev. 0 NEC005244 NECO05244

-NEC005245 perating Experience Review Report, Flow Accelerated Corrosion Program, LRPD-05, Rev. 0, NEC005246 NEC005246

-NEC005247 Operating Experience Review Report, Flow Accelerated Corrosion Program, LRPD-05, Rev. 0 NEC005248 NEC005248

-NEC005249 Operating Experience Review Report, Flow Accelerated Corrosion Program, LRPD-05, Rev. 0 NEC0052.50 NEC005250

-NEC005251 Monitoring Program -Flow Accelerated Corrosion Program NEC CD-I Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure

  • NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 LROO1 939 LROO1 940 LROO1941 LROO1 942 LROO1 943 LROO1 944 LROO1 945 LROO1 946 LROO1 947 LROO1 948 LROO1 949 LROO1 950 LROO1951 LROO1 952 LROO1 953 LR001954 LRO01 955 NEC005252 NEC005252

-. NEC005253 Operating Experience Review Report Section 3.8.1, NEC CD-i Initial Disclosure Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, DRAFT A 10-09-04 FAC NECO05254 NEC005254

-NEC005255 Operating Experience Review Report Section 3.81, NEC CD-i Initial Disclosure Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, DRAFT A 101104 FAC 6/20/2007 Exhibit I -Documents Produced for Contention NEC-4 (all productions)

NEC005256 NEC005256

-NEC005257 Operating Experience Review Report Section 3.8.1, NEC CD-i Initial Disclosure Flow-Accelerated Corrosion Program, LR3-VY-70 LRPD-05, DRAFT A, 101204 FAC: 71 72 73 74 75, 76.77 78 79 80 81 82 83 NEC005258 NECO05260 NEC005262 NECO05264 NEC005268 NECO05271 NECO05274 NECO05277 NEC005280 NECO05283 NECO05286 NEC005288 NECO05290 NECO05258

-NEC005259 Operating Experience Review Report Section 3.8.14, Flow-Accelerated Corrosion Program, LR3-.VY-LRPD-05, DRAFT A. 101304 FAC NEC005260

-NEC005261 Operating Experience Review Report Section 3.8.14, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, DRAFT A, 101304 Test FAC NEC005262

-NEC005263 Operating Experience Review Report, Section 1.1.1, LR3-wY-LRPD-05,-DRAFT-B, 101304 FAC NEC005264

-NEC005267 Operating Experience Review Report, Section 1.1.1 Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Revision 0, Draft C, 1/5105 FAC: NEC005268

-NEC005270 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 1/6/05 FAC: NECO05271

-NEC005273 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 1 605A FAC NECO05274

-NEC005276 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, V1105 FAC NEC005277

-NEC005279 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 1/111/05 FAC NEC005280

-NEC005282 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 11/11/04 FAC NEC005283.

-NEC005285 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 11/12/04 FAC NEC005286

-NEC005287 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 11/13104 FAC NEC005288

-NEC005289 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 11/15/04 FAC NEC005290

-NEC005291 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 11/17/04 FAC NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Diselosurb NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure 10/2312006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006.

10/23/2006 10/23/2006 10/2312006 10/23/2006 10/23/2006 10/23/2006 LR001956 LROO1 957 LROO1 958 LROO1 959 LR001960 LR001961 LROO1 962 LR001963 LROO1 964 LROO1 965 LROO1 966 LROO1 967 LROO1 968 LR001969 6/20/2007 Exhibit I -Documents Produced for Contention NEC-4 (all productions) 84 85 86 87 88 89 90 91 92 93 94 95 96 97 NECO05292.NEC005294 NECO05297 NEC005299 NECO05301 NEC005303 NEC005305 NEC005308 NECO0531 1 NEC005314 NEC005316 NEC00531 9 NECO05322 NECO05325 NEC005292

-NEC005293 Operating Experience Review Report, Section 1.1.1,* Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 12/01104 FAC NECO05294

-NEC005296 Operating Experience Review Report, Section-1.1.1

  • Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 12/09/04 FAC: NECO05297

-NEC005298 Operating Experience Review Report, Section 1.1.1

  • Flow-Accelerated Corrosion Program-, LR3-VY-LRPD-05, Draft C, 12110/04 FAC NECO05299

-NECO05300 Operating Experience Review Report, Section 1.1.1,* Flow-Accelerated Corrosion Program, LR3-WY-LRPD-05, Draft C, 12/13/04 FAC N.ECO05301

-NEC005302 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-WY-LRPD-05, Draft C, 12/14/04 FAC NECO05303

-NEC005304 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-WY-LRPD-05, Draft C, 1214a04 FAC NEC005305

-NEC005307 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-_VY-LRPD-05, Draft C, 12/115/04 FAC: NECO05308

-NEC005310 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-WY-LRPD-05, Draft C, 12/17/04 FAC NECOO53111

-NEC005313 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 12121/04 FAC NEC005314

-NEC005315 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 12120/04 FAC: NEC005316

-NEC005318 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 12128/04 FAC: NECO05319

-NEC005321 Operating Experience Review Report, Section i.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 12129/04 FAC NEC005322

-NEC005324 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 12130/04 FAC: NECO05325

-NEC005327 Operating Experience Review Report, Section 1.1.1, Flow-Accelerated Corrosion Program, LR3-VY-LRPD-05, Draft C, 12131/04 FAC NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-I Initial Disclosure NEC CD-I Initial Disclosure NEC CD-i Initial Disclosure 10/23/2006

.10/23/2006 10/23/2006

.10/23/2006 10/23/2006 10/23/2006.

10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006.

LROO1 970 LROO1971 LROO1 972 LROO1 973 LROO1 974 LROO1 975 LR001976 LROO1 977 LROO1 978 LROO1 979 LROO1980 LROO1981 LROO1 982 LROO1 983 6/20/2007 Exhibit I -Documents Produced for Contention NEC-4 (all productions) 98 99 100 101 102 103 104 105 106 107 108 109 110 Ill 112 NEC005328 NEC005344 NEC005360 NEC005376 NEC005391 NECO05406 NEC005421 NEC005436 NEC005452 NEC005467 NEC005483 NEC005498 NECO0551 3 NEC005676 NEC005723 NEC005328

-NEC005343 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, Draft B, 8/1104 NEC005344

-NEC005359 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 1/9/06 NEC005360

-NEC005375 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 1/91/66 NEC005376

-NEC005390 Aging Management Program Evaluation Results,-LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 1/10/06 -NEC005391

-NEC005405 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 1/16/06 NECO05406

-NEC005420 Aging Management Program Evaluation Results, LR3-LRPD-02 Revision 0, Fatigue Monitoring Program, 12121105 NEC005421

-NEC005435 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 10/04/05 NEC005436

-NEC005451 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 10106/05 NEC005452

-NEC005466 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 11/8/05 NEC005467

-NEC005482 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 11/15/05 NEC005483

-NEC005497 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitorinig Program, 11116/05 NEC005498

-NEC005512 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 11/17/05 NEC005513

-NEC005527 Aging Management Program Evaluation Results, LR3-LRPD-02, Revision 0, Fatigue Monitoring Program, 11121/05*NEC005676

-NEC005679 Screen Shot of Network Storage Location for Document Collection

-Trial folders and contens NEC005723

-NEC005808 NEC Petition to Intervene, Docket No. 50-217 NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-I Initial Dis closure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-i Initial Disclosure NEC CD-21 Initial Disclosure 10/23/2006 10/23/2006 10/23/2006 10/23/2006

-10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 LROO1 984 LROO1 985 L13001 986 LROO1 987.LROOI 988 LROO1 989 LROO1 990 LROO1 991 LROO1 992 LROO1 993 LROO1 994 LROQ1 995 LROO1 996 LR002050 LR002104 6/20/2007.

Exhibit I -Documents Produced for Contention NEC-4 (all productions) 113 114 115 117 118 119 120 121 122 123 124 125 126 127'128 129 130 NEC005818 NEC005818

-NEC005821 Print Screen of Test Folders NEC005898 NEC005898

-NEC005983.

Letter from NEC RE: NEC Petition to Intervene, Docket No. 50-217 NEC005984 NEC005984

-NECO06012 ENN-DC-315 Rev 1 Flow Acceleration Corrosion Program NECO06013 NECO06013

-NEC006023 EPU Presentation to Advisory Committee on Reactor Safeguards NEC006024 NEC006024

-NEC006025 Norman Rademacher Work contact information NEC006026 NEC006026

-NEC006029 LR Database Screens for Potential Contentions NECO06030 NECO06030

-NEC006033

Subject:

License Renewal Application, Ammendiment 13 Transmittal letter from Ted Sullivan, EntergyNVY, to NRC for Amnmendment 13.Docket No. 50-271 NEC007768 NEC007768

-NEC007797 XLetter to Entergy from Clifford J. Anderson, Chief Projects Branch 5, Division of Reactor Projects RE: NRC lntergrated Inspection Report.NEC007798 NEC007798

-NECO07800 Advisory Committee on Reactor Safeguards, Subcommitee on Uprates, Transcript (Nov. 30, 2005)NECO07801 NEC007801

-NEC008138 Original Official Transcript of Proceedings Advisory Committee on Reactor Safeguards, Subcommitee on Uprates, Transcript (Nov. 30, 2005) NRC-751 NEC008139 NEC008139

-NEC008355 Letter from Entergy to NRC RE: EPU Reponse to RAls NEC008675 NEC008675

-NEC008691 Letter from entergy to NRC RE: EPU Response to RAls NEC008692 NEC008692

-NEC008877 Draft WY Piping Flow Accelerated Corrosion Inspection Program EPRI Checworks Wear Rate Analysis Results (with hand written notes)NEC008878 NEC008878

-NECO09141 VY Piping FAC Inspection Program records for the 1996 Refueling Outage NEC009142 NEC009142

-NEC009548 VY Piping FAC Inspection Program records for the 1998 Refueling Outage NEC009549 NEC009549

-NEC009895

'A' Piping FAC Inspection Program records for the 1999 Refueling Outage NEC009896 NEC009896

-NEC009906 Checworks Integrated Software for Corrosion Control NEC009907 NEC009907

-NECO09910 Article RE: Predicting corrosion damage with the..CHECWORKS software package NEC CD-2 initial Disclosure NEC CD-2 initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initilal Disclosure NEC CD-21 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure NEC CD-2 Initial Disclosure 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/2 3/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 10/23/2006 LROO21 27 LROO2172 LROO21 76 LR002177 LR0021 90 LR002202 LR002206 LR002858 LR002859 LR002860 LR002861 LR003275 LR003278 LR003279 LR003280 LR003281 LR003283 LR003284 6/20/2007 Exhibit I -Documents Produced for Contention NEC-4 (all productions) 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 NEC017321 NECO1 7322 NECO17324 NECO17737 NECO17789 NEC017817 NEC017851 NECO17880 NECO17888 NECO17913 NECO17926 NECO17941 NEC017974 NEC017977 NECO1 8005 NEC017321

-NECO17321 NEC017322

-NECO17323 NEC017324

-NEC017343 NEC017737

-NEC017788 NEC017789

-NEC017816 NEC017817

-NEC017850 NEC017851

-NEC017879 NEC017880

-NEC017887 NECO17888

-NEC017912 NECO17913

-NEC017925 NEC01796 -NECO17940 NECO17941

-NEC017973 NEC017974

-NEC017976 NECO17977

-NECO18004 NECO18005

-NECO18143 Vermont License Renewal FAC question NEC CD-s Supplement 1 Disclosure Entergy License Renewal and FAC NEC CD-s Supplement 1 Disclosure FN: Entergy Nuclear Vermont Yankee LLC (Dkt NEC CD-s Supplement 1 No. 50-2711-1-1)

Disclosure VY Department Procedure 0072 DP 0072 NEC CD-s Supplement 1 Structural Evaluation of Thinned Wall Piping Disclosure Components -LPC-1 Procedure Cancellation DP 4023 Rev 2 NEC CD-s Supplement 1 Disclosure ENN-CS-S-008 Pipe Will Thinning Structural NEC CD-s Supplement 1 Evaluation Disclosure ENN-DC-315 Revi / FAC Program NEC CD-s Supplement 1 Disclosure ENN-NDE-9.05 UIT Thickness NEC CD-s Supplement 1 Disclosure VY Piping FAC Inspection Program PP 7028 NEC CD-s Supplement 1 Disclosure VY Piping FAC Inspection Program NEC CD-s Supplement 1 Disclosure VY Piping FAC Inspection Program NEC CD-s Supplement 1 Disclosure VY Piping FAC Inspection Program NEC CD-s Supplement 1 Disclosure-NE 8053 -Ultrasonic Thickness Measurement LPC- NEC CD-s Supplement 1 I VYNEF 8053.01 Pg 1 of 1. Disclosure Nondestructive Examination Prodedure NE 8053 NEC CD-s Supplement'l1 Ultrasonic Thickness Measurement Disclosure-Program Procedure 7028 Piping Flow- NEC CD-s Supplement 1 Accelerated Corrosion Inspection Program LPC-11 Disclosure 1211/2006 12/7/2006 1217/2006 1217/2006 1217/20)06

.12(7/2006 1211/2006 1217/2006 12(17/2006 1217/2006 12(7/2006 12(7/2006 12/7/2006 1217/2006 1217/2006 12/7/2006 12(7/2006 12f7/2006 12f7/2006 12f7/2006 12/7/2006 LR002788 LR002789 LR002800 LR002890 LR002891 LR002892 LR002893 LR002894 LR002895 LR002896 LR002897 LR002898 LR002899 LR002900 LR002901 LR002902 LR002903 LR002904 LR002905 LR002906 LR002907 NEC018144 NEC018144

-NEC018575 Controlled Document Transfer for Permanent 146 Storage NEC018576 NEC018576

-NEC018617 Engineering Report Title: VY Piping FAC Inspection 147 Program-FAC Susceptibility Review NEC0186118 NEC018618

-NEC019230 Piping FAC Inspection Program 148 NEC019231 NEC019231

-NECO19291 VY Piping FAC Inspection Program 149 NEC019292 NEC019292

-NEC019417 VY Piping FAC Inspection Program 150 NEC019418 NECO19418

-NEC019431 VY Piping FAC Inspection Program 151 NEC CD-s Supplement 1 Disclosure NEC CD-5 Supplement 1 Disclosure NEC CD-S Supplement 1 Disclosure NEC CD-s Supplement 1 Disclosure NEC CD-s Supplement 1 Disclosure NEC CD-s Supplement 1 Disclosure 6120/2007 f.152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 NECO19432 NEC019513 NECO1 9863 NEC020179 NEC020630 NECO21 109 NEC021 110 NEC021 112 NEC021 116 NEC022215 NEC023637 NEC023638 NEC023639 NEC023640 NEC023641 NEC023643 NEC023644 NEC023645 NEC023685 NEC023686 NECO23726 Exhibit I -Documents Produced, for Contention NEC-4 (all productions)

NEC019432

-NECO19512 VY Piping FAC Inspection Program NEC CD-S Supplement I Disclosure NECO19513

-NEC019862 PP 7028 FAC Inspections 2001 Refueling Outage NEC CD-S Supplement 1 Disclosure NEC019863

-NEC020178 PP 7028 FAC Inspections 2002 Refueling Outage NEC CD-S Supplement I Disclosure NEC020179

-NEC020629 PP 7028 FAC Inspections 2004 Refueling Outage NEC CD-S Supplement 1 Disclosure NEC020630

-NEC020976 PP 7028 Piping FAC Inspection Program NEC CD-S Supplement 1 Disclosure NEC021109

-NEC021109 SOFTWARE CONTROLS AND LICENSE NEC CD-6 Supplement I RENEWAL Disclosure NECO21I110

-NECO21 111 RE: Vermont License Renewal FAC question NEC CD-6 Supplement 1 Disclosure NEC02I1112

-NEC021 113 RE: Vermont License Renewal FAC question [12-02. NEC CD-6 Supplement 1 04] Disclosure N EC021 116 -NEC021268 FW: VY Status Updates NEC022215

-NEC022269 NEC023637

-NEC023637 NEC023638

-NEC023638 NEC023639 -NEC023639 NEC023640

-NEC023640 NEC023641

-NEC023642 NEC023643

-NEC023643 FW: VY AMRM-33 RPV Email re License Renewal FAC program Email re Operating Experience Review for FAC and Fatigue Monitoring Program Operating Experience Review for FAC and Fatigue Monitoring Program -Interview Questions Email forwarding Needs for TLAA and Fatigue Reports Needs for TLAA and Fatigue Reports Email re License Renewal Project NEC CD-6 Supplement I Disclosure NEC CD-6 Supplement I Disclosure NEC CD-6 Supplement I Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement"1 Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement 1 Disclosure-.

NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement I Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement 1 Disclosure 12/7/2006 12t712006 1217/2006 12/7/2006 12t/72006 12/7/2006 12/7/2006 12/7/2006 12/7/2006 12/7/2006-12/7/2006 12/7/2006 12/7/2006 12/7/2006 12/7/2006 12t7/2006 12/7/2006 12/7/2006 12/7/2006 12t7/2006 12/7/2006 LR002908 LR002909 LR00291 0 LR00291 1 LR002912 LR003320 LR003321 LR003322 LR003325 LR003400 LR008733 LR003734 LR003735 LR003736 LR003737 LR003738 LR003739 LR003740 LR003742 LR003743 LR003744 NEC023644

-NEC023644 Email re LRPD-04, "TLAA -Mechanical Fatigue, Draft-A 10/6/04 NEC023645

-NEC023684 LRPD-04, "TLAA -Mechanical Fatigue".

Draft-A 10/6/04 Report NEC023685

-NEC023685 Email re LRPD-04, "TLAA -Mechanical Fatigue", Draft-B 7/28/0S VY Comments lncorp.NEC023686

-NEC023725 LRPD-04, "fTLAA -Mechanical Fatigue", Draft-B 7/28/05 'A' Report NEC023726

-NEC023730 LRPD-04, "TLAA -Mechanical Fatigue", Draft-B 7/28/OS VY Comments Form 6/20/2007 Exhibit I -Documents Produced for Contention NEC-4 (all productions)

NEC023731 NEC023731

-NEC023732 Email re LRPD-04 TLAA -Metal Fatigue 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 NEC023733 NEC023773 NEC023783 NEC023800 NEC024371 NEC024374 NEC024377 NEC037099 NEC038398 NEC038416 NEC038419 NEC023733

-NEC023772 LRPD-04 TLAA -Metal Fatigue Report, Draft B, Rev. 0 NEC023773

-NEC023782 Memo re Minor Reroute of RWCU Piping NEC023783

-NEC023799 LRPD-04 TL.AA -Metal Fatigue -Revision Status Sheet NEC023800

-NEC023802 LRPD-04 TLAA -Metal Fatigue Report NEC024371

-NEC024373 VY FAC Program -NEC024374

-NEC024376 VY Review of FAC Program & Inspection Efforts NEC024377

-NEC024381 FAC Management NEC037099

-NEC037445 PP 7028 Piping FAC Inspection Program FAC Inpection Program Records for 2005 Refueling OUtage NEC038398

-NEC038415 Chemistry Monthly Report Juley 2006 NEC038416

-NEC038418 Condition Report CR-VTY-2005-02239 NEC038419

-NEC038449 Cornerstone Rollup Program: Accelerated NEC CD-6 Supplement I Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement I Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-.6 Supplement I Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-6 Supplement 1 Disclosure NEC CD-li Supplement 1 Disclosure NEC CD-16 Supplement 6 Disclosure NEC CD-16 Supplement 6 Disclosure NEC CD-16 Supplement 6 12/7/2006 12/7/2006 12/7/2006 12(7/2006 12/7/2006 12/7/2006 1217/2006 1217/2006 1217/2006 5/3/2007 5/3/2007 5/3/2007 5/3/2007 5/3/2007 5/3/2007 5/3/2007 5/3/2007 6/7/2007 LR003745 LR003746 LR003747 LR003748 LR003749 LR003772 LR003773 LR003774 LR004804 LR005938 LR005939 LR005940 LR005941 LR005942 LR005943 LR005944 LR006001 LR00661 9 Corrosion Disclosure-NEC038450 NEC038450

-NEC038461 Review of the Vermont Yankee Nuclear Plant Flow -NEC CD-16 Supplement 6 Accelerated Corrosion Program Disclosure NEC038462 NEC038462

-NEC038504 Focused Self-Assessment Report: Vermont Yankee NEC CD-16 Supplement 6 Piping Flow Accelerated Corrosion Inspection Disclosure Program NEC038505 NEC038505

-NEC038512 Vermont Yankee Nuclear Power Station -NRC NEC CD-1 6 Supplement 6 Integrated Inspection Report -Disclosure NEC038513 NEC038513

-NEC038555 Quality Assurance Division Vermont Yankee NEC CD-16 Supplement 6 Nuclear Power Plant -Programs Audit Disclosure NEC038556 NEC038556

-NEC038561 Sa fety Evaluation Report with Confirmatory Items NEC CD-16 Supplement 6 Related to the License Renewal of Vermont Yankee Disclosure Nuclear Power Station Docket NO. 50-271 NEC044876 NEC044876

-NEC044880 Summary of Observations During VY Site Visit NEC CD-17 Supplement 7 Disclosure 6/7/2007 6/20/2007 Exhibit 2 -Documents Produced for Contention NEC-4 in 2007 Prodno NEC038398 NEC038416 NEC038419 NEC038450 NEC038462 NEC038505 NEC03851 3 NEC038556 Bates Range Document Title CD NEC038398

-NEC038415 Chemistry Monthly Report Juley 2006 NEC CD-16 Supplement 6 Disclosure NEC038416

-NEC038418 Condition Report CR-VTY-2005-02239 NEC CD-16 Supplement 6 Disclosure NEC038419

-NEC038449 Cornerstone Rollup Program: Accelerated NEC CD-16 Supplement 6 Corrosion Disclosure NEC038450

-NEC038461 Review of the Vermont Yankee Nuclear Plant Flow -NEC CD-16 Supplement 6 Accelerated Corrosion Program Disclosure NEC038462

-NEC038504 Focused Self-Assessment Report: Vermont Yankee NEC CD-16 Supplement 6 Piping Flow Accelerated Corrosion Inspection Disclosure Program NEC038505

-NEC038512 Vermont Yankee Nuclear Power Station -NRC NEC CD-16 Supplement 6.Integrated Inspection Report Disclosure NEC038513

-NEC038555 Quality Assurance Division Vermont Yankee NEC CD-16 Supplement 6 Nuclear Power Plant -Programs Audit Disclosure NEC038556

-NEC038561 Safety Evaluation Report with Confirmatory Items NEC CD-16 Supplement 6 Related to the License Renewal of Vermont Yankee Disclosure Nuclear Power Station Docket NO. 50-271 Production Date Docdd it nf Pin~# of Panes 5/3/2007 5/3/2007 5/3/2007 5/3/2007 5/3/2007 5/3/2007 5/3/2007 5/3/2007 6/7/2007 LR005938 LR005939 LR005940 LR005941 LR005942 LR005943 LR005944 LR006001 LR00661 9 18 3 31 12 43 8 43 NEC044876 NEC044876

-NEC044880 Summary of Observations During VY Site Visit NEC CD-17 Supplement 17 Disclosure 6/7/2007 6 5.6/20/2007