Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Report dateSiteEvent description
05000267/LER-1950-267, Advises That Status Rept Re Corrective Actions Resulting from LER 50-267/86-017 Delayed Due to Further Investigation of Transient Effects on Helium Purification Sys.Commmitment Extended to 861219Fort Saint Vrain
05000267/LER-1976-002, Suppl to LER 76-002A:on 760116,during Operation of Circulator W/Water Turbine Drives,Circulator Speed Reduced. Caused by Water Accumulation in Turbine Scroll Case. Investigation ContinuingFort Saint Vrain
05000267/LER-1976-010, Handwritten LER 76-010A:on 760503,helium Circulators 1A & 1B Tripped.Caused by Bearing Water Pump Trip Due to Decreased Bearing Water Surge Tank Loop 1 Water Level. Appropriate Procedure Changes ImplementedFort Saint Vrain
05000267/LER-1976-011, Handwritten LER 76-011:on 760520,helium Circulator 1C Tripped Due to Negative Buffer Differential Pressure.Caused by Concurrent Sys Complexity & Confusion Associated W/Shift ChangeFort Saint Vrain
05000267/LER-1976-012, Handwritten LER 76-012:on 760527,circulator 1B Tripped. Caused by Buffer Seal Malfunction.Sys Operating Procedure for Reset Following Trip Will Be revised.W/760607 LtrFort Saint Vrain
05000267/LER-1976-013, Handwritten LER 76-013:on 760607,circulators Tripped Due to Trouble Shooting.Caused by Pulled Module Interlock Circulator Isolation Relays.Modules inserted.W/760617 LtrFort Saint Vrain
05000267/LER-1976-024, Update 1 to LER 76-024:on 760726,circulator 1C Tripped on Buffer Upset Following Discharge Valve Opening During Helium Recirculator Return to Svc.Caused by Buffer Differential Pressure Exceeding Trip PointFort Saint Vrain
05000267/LER-1977-002, Updated LER 77-002A:on 761227,during Electrohydraulic Control Hydraulic Pump Test,Main Turbine Tripped.Trip Caused Loss of Power to Helium Circulator Bearing Water Pumps. Caused by Pump Control MalfunctionFort Saint Vrain
05000267/LER-1977-034, Forwards Updated LER 77-034/03X-1 & LERs 83-025/03L-0 & 83-026/03L-0Fort Saint Vrain
05000267/LER-1977-036, Forwards LER 77-036/03L-1Fort Saint Vrain
05000267/LER-1978-018, Forwards LER 78-018/03X-2Fort Saint Vrain
05000267/LER-1978-025, Forwards LER 78-025/01X-1Fort Saint Vrain
05000267/LER-1978-027, Forwards LER 78-027/03X-2,suppl ReptFort Saint Vrain
05000267/LER-1978-029, Forwards LER 78-029/03L-0Fort Saint Vrain
05000267/LER-1978-030, Forwards LER 78-030/03L-0Fort Saint Vrain
05000267/LER-1978-032, Forwards LER 78-032/03L-0Fort Saint Vrain
05000267/LER-1978-040, Forwards LER 78-040/03L-0Fort Saint Vrain
05000267/LER-1979-001, Forwards LER 79-001/03L-0Fort Saint Vrain
05000267/LER-1980-030, Revised LER 80-030/03X-3:on 800604,during Normal Operation, Loop 2 Steam Generator Penetration Leakage Greater than Tech Spec Limits.Caused by Inadequate Tech Specs.Tech Specs ModifiedFort Saint Vrain
05000267/LER-1981-036, Forwards Updated LER 81-036/01X-1 & LER 83-049/03L-0Fort Saint Vrain
05000267/LER-1981-068, Revised LER 81-068/03X-2:on 811024,during Plant Temp Fluctuation Testing,Loop 2 Steam Generator Interspace Leakage Exceeded Tech Spec Limits.Caused by Inadequate Tech Specs.Tech Specs RevisedFort Saint Vrain
05000267/LER-1981-071, Forwards LER 81-071/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-017, Forwards LER 82-017/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-018, Forwards LER 82-018/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-019, Forwards LER 82-019/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-020, Forwards LER 82-020/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-023, Forwards LER 82-023/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-024, Forwards LER 82-024/03X-2.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-025, Forwards LER 82-025/03L-1.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-026, Forwards LER 82-026/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-027, Forwards LER 82-027/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-028, Forwards LER 82-028/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-029, Forwards LER 82-029/03X-1.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-030, Forwards LER 82-030/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-031, Forwards LER 82-031/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-034, Forwards LER 82-034/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-035, Forwards LER 82-035/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-037, Forwards LER 82-037/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-038, Forwards LER 82-038/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-039, Forwards LER 82-039/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-040, Forwards LER 82-040/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-043, Forwards LER 82-043/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-044, Forwards LER 82-044/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-045, Forwards LER 82-045/03L-0Fort Saint Vrain
05000267/LER-1982-046, Forwards LER 82-046/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-047, Forwards LER 82-047/03L-0.Detailed Event Analysis EnclFort Saint Vrain
05000267/LER-1982-048, Final LER 82-048/03X-1:on 821207,primary Coolant to Purification Cooling Water Sys Leak Present in Purification Train B Helium Purification Cooler.Caused by Corrosion. Cooler ReplacedFort Saint Vrain
05000267/LER-1982-049, Forwards LERs 83-031/03L-0 & 83-032/03L-0 & Updated LER 82-049/01X-1.Detailed Summary EnclFort Saint Vrain
05000267/LER-1982-052, Revised LER 82-052/03L-1:during 821229-830111,eight Class I Hydraulic Shock Suppressors Found Inoperable.Caused by Improper Reservoir Orientation or Lack of Oil Due to Pipe Movement.Snubbers Rebuilt,Tested & Reinstalled or ReplFort Saint Vrain
05000267/LER-1983-002, Forwards LER 83-002/03L-0.Detailed Event Analysis EnclFort Saint Vrain