Issue date | Title | Topic | |
---|---|---|---|
ML19325C199 | 5 October 1989 | LER 89-015-00:on 890905 & 23,special Ventilation Sys of Control Rooms 122 & 121 Actuated Automatically.Caused by False High Chlorine Signal & Broken Chlorine Sensitive Paper Tape,Respectively.Detectors repaired.W/891005 Ltr | |
ML19325C749 | 10 October 1989 | LER 89-016-00:on 890908,control Room Received Train B High Radiation Alarm,Which Initiated Automatic Start of Auxiliary Bldg Special Ventilation Sys.Caused by Spike on Radiation Monitor 2R-30.Monitor Upgrade Being pursued.W/891010 Ltr | |
ML19325D490 | 16 October 1989 | LER 89-017-00:on 890914,discovered That Present Position of Transfer Switch for Power Supplying Control & Protection Relays for Diesel Generator Does Not Meet Requirements of App R.Caused by Inadequate procedures.W/891016 Ltr | Safe Shutdown |
ML19330A872 | 24 July 1980 | LER 80-019/03L-0:on 800630,two Power Range High Power Trip Setpoints Were Over Tech Spec Limit.Caused by Personnel Error.Rept Reviewed & Technicians Cautioned | |
ML19330B466 | 29 July 1980 | LER 80-020/01T-0:on 800715,during Severe Electrical Storm Several Breakers Operated.Main Generator Was Separated from Grid & Reactor & Reactor Coolant Pumps Tripped.Caused by Electrical Storm.Next Day Conditions Returned to Normal | |
ML19332C617 | 22 November 1989 | LER 89-018-00:on 891024,25 & 1112,control Room Received Train a High Radiation Alarm,Initiating Automatic Start of Auxiliary Bldg Special Ventilation Sys.Caused by Spike of Radiation Monitor.Monitor replaced.W/891122 Ltr | |
ML19332C624 | 22 November 1989 | LER 89-003-00:on 891023,measured Leakage Rate Exceeded Tech Specs Limit While Performing Surveillance Test Sp 2136. Caused by Wear of Grafoil Packing Due to High Frequency of Door Usage.Test Procedures modified.W/891122 Ltr | |
ML19332C700 | 20 November 1989 | LER 89-019-00:on 891025,Train a of Auxiliary Bldg Special Ventilation Sys Started Automatically When Power Mistakenly Turned Off.Caused by Personnel Error.Involved Personnel Counseled.Clarifying Revs Made to procedure.W/891121 Ltr | |
ML19337A261 | 5 September 1980 | LER 80-024/03L-0:on 800829,failure to Perform Inservice Insp of Safety Nozzle to Shell Weld of Both Reactor Vessels Was Noted.Cause Due to Equipment Unavailablilty.Rescheduling Requested for 1983 & 1984 Outages | |
ML19338C935 | 2 September 1980 | LER 80-022/03L-0:on 800805,during Surveillance test,fan-coil Unit Dome Damper 23 Could Not Be Positioned Properly.Caused by Leaking Air Supply Line to Damper Actuator.Air Supply Line Replaced | |
ML19338D778 | 18 September 1980 | LER 80-025/01T-0:on 800904,during Refueling Shutdown, Ultrasonic Exam of Steam Generator Support Bolts Revealed Crack Indications.Unit 2 Also Inspected.Caused by Environ Assisted Cracking.All Unit 1 Bolts Will Be Replaced | |
ML19338D788 | 19 September 1980 | LER 80-023/03L-0:on 800820,during Review of Surveillance Program Annual test,SP1185 for Control Room Special Ventilation Flow Verification Found Omitted for 1978-1980. Caused by Personnel Error.Personnel Will Review Rept | |
ML19338F514 | 13 October 1980 | Updated LER 80-10/03L Dtd 801008,has Been Cancelled | |
ML19338F550 | 15 October 1980 | LER 80-026/03L-0:on 800916,while Performing Fire Protection Mod Work in Auxiliary Feedwater Pump 22,workman Accidentally Bumped Overspeed Trip Mechanism,Tripping Valve & Making Pump Inoperable for 15 Minutes.Caused by Personnel Error | |
ML19339B199 | 31 October 1980 | LER 80-028/03L-0:on 801003,previously Acknowledged Annunciator Indicating Fan Coil Unit 24 Was Noticed in Local Control.Caused by Personnel Error.Switch Returned to Remote & Personnel Cautioned to Exercise Care | |
ML19339B205 | 31 October 1980 | LER 80-029/03L-0:on 801004,inverter 23 Failed,Leaving Panel 213 de-energized.Caused by Failure of Sola Constant Voltage Transformer.Panel Transferred & Transformer Replaced | |
ML19339C618 | 12 November 1980 | LER 80-032/03L-0:on 801013,during Refueling,Circulating Water Intake Bay Was Drained.Caused by Inoperable Priming Exhauster & Cooling Water Pump 21.Piping Mods Are Being Considered to Allow Maint W/O Effecting Operation | |
ML19340B255 | 17 October 1980 | LER 80-027/03L-0:on 800919,steam Flow Transmitter 2FT-474 Found Reading Low.Caused by Zero Adjustment Shift in Barton Model 384 Differential Pressure Transmitter. Transmitter Recalibr.Transmitters Scheduled to Be Replaced | |
ML19340B590 | 7 November 1980 | LER 80-030/03L-0:on 801008,diesel Generator D2 Tripped on High Crankcase Pressure When Eductor Hose Failed.Caused by Burst Eductor Hose.Hose Replaced on Both Diesel Engines | |
ML19341A671 | 21 January 1981 | LER 80-038/03L-0:on 801222,during Surveillance Test,One Steam Exclusion Actuation Bistable Tripped Above Tech Spec Limit.Caused by Drift of Foxboro Model 63U-CC-OHDR-F Bistable.Bistable Reinspected & Calibr | |
ML19343B187 | 3 December 1980 | Supplemental LER 80-025:on 800904,during Mounting Bolt Insp, Three Defective Vascomax 250 Cvm Bolts Were Discovered in Steam Generator 22.Caused by Stress Corrosion Cracking.New Bolts Were Installed & Tensioned to 50 Ft Lb | |
ML19343B203 | 11 December 1980 | LER 80-037/03L-0:on 801117,during Review for Upgrading Environ Qualification of safety-related Electrical Equipment,It Was Determined That Namco Switches Were Not Hermetically Sealed.Caused by Installation Error | |
ML19344A801 | 15 August 1980 | LER 80-021/03L-0:on 800718,w/unit at Cold Shutdown for Steam Generator Maint & Insp,Replacement of Inverter 13 Revealed Lack of Seismic Analysis for Mounting Inverter.Caused by Personnel Error | |
ML19344D243 | 6 March 1980 | Updated LER 80-003/01x-1:on 800109,during Eddy Current Test of Tubes in Unit 2 Steam Generators,Indications of Tube Degradation Were Seen.Caused by Corrosion.Several Tubes Plugged & One Removed for Further Examination | |
ML19345B120 | 21 November 1980 | LER 80-034/03L-0:on 801031,auxiliary Bldg Special Vent Exhaust Fan 122 Tripped.Caused by Actuation of Thermal Overload Protective Device.Device Replaced | |
ML19345B527 | 26 November 1980 | LER 80-033/03L-0:on 801028,steam Flow Transmitter 1FT-464 Observed Reading Low.Caused by Zero Adjustment Shift in Barton Model 384 Differential Pressure Transmitter.Device Recalibr | |
ML19345F621 | 10 February 1981 | LER 81-001/03L-0:on 810112,while Performing Mod Work,Workman Accidentally Bumped Overspeed Trip Mechanism of Auxiliary Feedwater Pump,Tripping Valve & Making Pump Inoperable. Caused by Personnel Error.Valve Operator Reset | |
ML19347A943 | 25 September 1980 | Updated LER 80-025/01T-1:on 800904,ultrasonic Examination of Steam Generator Support Bolts Revealed That Most Had Crack Indications.Preliminary Cause Suggests Environmentally Assisted Cracking | |
ML19347B635 | 8 October 1980 | Updated LER 80-010/03L-1:on 800311,containment Vacuum Breaker Isolation Valve 11 Opened at 0.57 Psi Rather than 0.5 Psi.Caused by Drift in Differential Pressure Switch. Setpoint Adjusted & Satisfactorily Tested | |
ML19347B642 | 8 October 1980 | Updated LER 80-021/03L-1:on 800718,replacement of Inverter 13 Was Stopped Due to Lack of Seismic Analysis for Inverter Mount.Caused by Personnel Error.Improvement in Design Change Process Initiated | |
ML19347B646 | 8 October 1980 | Updated LER 80-024/03L-0:on 800829,failed to Perform Inservice Insp of Safety Injection Nozzle to Shell Weld of Both Reactor Vessels.Caused by Unavailability of Test Equipment.Tech Spec & ASME Code Revisions Requested | |
ML19350B524 | 13 March 1981 | LER 81-002/01T-0:on 810301,during Eddy Current Exam of Steam Generator Tubes,Tubes Found Degraded & Defective.Caused by Corrosion &/Or Fretting.Defective Tubes Plugged | |
ML19350D662 | 15 May 1981 | LER 81-005/03L-0:on 810423,containment Vacuum Breakers Test Sp 2130 Was Discovered to Not Have Been Performed.Caused by Personnel Oversight.Preheatup Surveillance Test Scheduling Will Be Changed | |
ML19351A468 | 11 December 1989 | LER 89-020-00:on 891108,17,20,23,1201 & 08,automatic Isolation of Control Room Supply & Exhaust Occurred.Caused by Malfunctions of Chlorine Gas Detectors.Addl Monitors Installed & Actuation Logic modified.W/891211 Ltr | |
ML20002A826 | 14 November 1980 | LER 80-031/03L-0:on 801017,during Surveillance Program Review,Discovery Was Made That Steam Exclusion Test SP1112 Was Not Done for Sept 1980.Caused by Personnel Oversight. No Changes Considered.Involved Personnel Will Review Rept | |
ML20002B043 | 3 December 1980 | LER 80-036/03L:on 801105,battery Charger 12 Failed to Provide Normal Output.Caused by Firing Card B Not Providing Pulses to Fire B Phase Scr.Card Replaced | |
ML20002B069 | 3 December 1980 | LER 80-035/03L-0:on 801103,remote/local Control Switch on Containment Spray Pump 21 Found Not in Remote Position. Caused by Contractor Workman Bumping Switch.Switch Returned to Remote Position | |
ML20003F486 | 14 April 1981 | LER 81-003/03L-0:on 810316,during Surveillance Test,Steam Exclusion Damper Actuation Setpoint Exceeded Limit.Caused by Foxboro Model 63U-CC-OHDR-F 6 Bistable Drift.Instrument Recalibr & Tested Satisfactorily | |
ML20003H983 | 5 May 1981 | LER 81-004/03L-0:on 810406,during testing,turbine-driven Auxiliary Feedwater Pump 22 Failed to Come Up to Rated Speed.Caused by Low Governor Setting.Governor Adjusted to Proper Speed | |
ML20004D513 | 5 June 1981 | LER 81-006/03L-0:on 810507,charging Pump 121 Drive Unit Failed.Caused by Bearing Failure in Varidrive Unit.Damaged Parts Replaced | |
ML20005D707 | 30 November 1989 | LER 89-018-01:on 891024,25,31 & 1112,control Room Received High Radiation Alarm Which Initiated Automatic Start of Auxiliary Bldg Special Ventilation Sys.Caused by Radiation Monitor Spikes.Monitor Modules replaced.W/891130 Ltr | |
ML20005G373 | 11 January 1990 | LER 89-021-00:on 891211,computer Alarmed Indicating Malfunction of Chlorine Monitors 121 & 122 & Leaving Control Room Ventilation Sys Inoperable for More than 11 H.Caused by Personnel Error.Monitor 122 Returned to normal.W/900111 Ltr | |
ML20006A972 | 22 January 1990 | LER 89-004-00:on 891221,unit Tripped & Reactor Coolant Pumps Lost Power.Caused by Faulty Voltage Regulation of One CRD Mechanism motor-generator Set.Regulator for Set Replaced & Tested.On 891226,identical Trip occurred.W/900122 Ltr | |
ML20006E458 | 16 February 1990 | LER 90-001-00:on 900117,technician Mirror Contacted Bare Power Supply Terminal & Shorted Terminal to Ground,Causing Power Supply to Trip & Isolation of Outside Air to Control Room.Exposed Wire Terminal Points covered.W/900216 Ltr | |
ML20006E821 | 20 February 1990 | LER 90-002-00:on 900117,review of Cooldown Data Showed That Cooldown Rate of Pressurizer Exceeded Tech Spec Limit.Caused by Procedure Inadequacy.Procedures Revised to Require Use of Water Space Temp to Find Cooldown rate.W/900220 Ltr | |
ML20009D559 | 17 July 1981 | LER 81-008/01T-0:on 810611,shaft Vibration on Reactor Coolant Pump 21 & Seal 1 Leakoff Flow Increased Beyond Normal Range.Pump Disassembled.On 810706,circumferential Crack Discovered.Cause Not Determined | |
ML20010C314 | 7 August 1981 | LER 81-009/03L-0:on 810708,while Attempting Start of Cooling Tower Pump 122,undervoltage Relay Operation Opened Breaker CT 11-1,closed Bus Tie CTBT-112 & Caused Trip of Bus CT-12. Caused by Improperly Set Undervoltage Relay Setpoint | |
ML20010F418 | 1 September 1981 | LER 81-010/03L-0:on 810807,rod Position Indication Channel K7 Found Drifted Low & Declared Inoperable.Cause Undetermined But Probably in Reactor Vessel Head.Repairs Will Be Made at Shutdown | |
ML20011A860 | 26 October 1981 | LER 81-020/01T-0:on 811011,Westinghouse Nbfd Relays in Reactor Protection Sys for Units 1 & 2 Found to Have Failed Relay Coils.Caused by Failure of Solder Joint Pigtail Connection Coil to Lead Wire | |
ML20012D494 | 19 March 1990 | LER 89-004-01:on 891221,reactor Trips & Loss of Power to Reactor Coolant Pumps Occurred.Caused by Malfunctions in MG Sets,Rod Control Sys & Substation Breaker Control Sys. Voltage Regulator for MG Set replaced.W/900319 Ltr |