ML20085G09829 October 1973AO BFAO-7330W:on 731019,approx 1,400 Gallons Unanalyzed Liquid Radwaste Released Into River.Caused by Placing Floor Drain Sample Tanks on Recycle Before Sampling Contents. Procedures Will Be Changed
ML20085G10619 October 1973Telecopy AO on 731019,unanalyzed Radwaste Released Into River.Discharge Activity Did Not Exceed License Limit
ML20085G11317 January 1975AO BFAO-50-260/751W:on 750107,RCIC Failed to Operate After Planned Turbine Trip.Caused by Electronic Overspeed Trip Due to Dropping Resistor Open Circuiting in Resistor Box. Resistor Replaced & Voltage Verified
ML20085G11626 October 1973AO BFAO-7329W:on 731018 & 19,HPCI Inverter Power Supply Fuse Failed.Caused by Wiring Error Resulting from Design Change. Wiring Corrected & Tested
ML20085G12222 October 1973Telecopy AO BFAO-7329T:on 731018 & 19,HPCI Inverter Power Supply Fuse Blew.Fuse Replaced & Failed Again.Fuse Replaced & Accelerated Program to Determine Cause Initiated
ML20085G12629 November 1974AO BFAO-50-260/7427W:on 741121,core Spray Injection Valve 2-FCV-75-53 Failed to Open.Caused by Jammed Valve Due to Misadjustment of Closing Limit Switch on Valve Operator. Opening & Closing Limit Switches Adjusted
ML20085G14526 October 1973AO BFAO-7328W:on 731017,HPCI Condensate Header Low Level Switches LS-73-56A & B Exceeded Tech Spec Limit.Caused by Sluggish Switch Spring Mechanisms.Wider Air Gap Established, Switches Reset & Test Frequency Increased
ML20085G15418 October 1973Telcopy AO BFAO-7328T:on 731017,HPCI Condensate Header Low Level Switches LS-73-56A & B Exceeded Tech Spec Trip Level Settings
ML20085G16127 December 1974AO BFAO-50-260/7436W:on 741218,drywell Sampling Monitor Found 2-RM-90-256 Inoperable.Caused by Failure of Four 150- Watt Bulbs Used for Heating Monitor Internals.Permanent Heating Sys in Drywell Requested
ML20085G18624 October 1973Ao:On 730925,trip Setpoint of 152 Inches for HPCI Flow Switch DPIS 3-2353 Exceeded Tech Spec Limit.Caused by Locking Device Failing to Control Setpoint Drift.Switch Setpoint Changed & Calibr Frequency Increased
ML20085G18826 October 1973AO BFAO-7327W:on 731016,setpoint of 1.8 Psid for Recirculation Jet Pump Riser Differential Pressure Switch PdIS-68-24 Exceeded Tech Spec Limit.Switch Recalibr,Tested & Frequency Increased to Once Every 2 Wks
ML20085G22710 February 1975AO BFAO-50-259/751W:on 750131,time for RHRSW Pump D1 Start Sequence Time Delay Relay TD1-D Improperly Set.Caused by Inadvertent Moving of Timer Dial Setting Since Previous Surveillance Test.Relay Recalibr
ML20085G22925 October 1973AO BFAO-7326W:on 731015,trip Settings of Differential Pressure Switches PdIS-68-85,PdIS-68-89 & PdIS-68-90 Exceeded Tech Spec Limit.Switches Recalibr & Frequency of Testing Increased to Once Every 2 Wks
ML20085G23927 December 1974AO BFAO/50-260/7435W:on 741218,flow Control Valve 2-FCV-74-66 on RHR Sys Loop II Failed to Open.Caused by Loose Locknut Due to Missing Set Screws in Yoke Nut Bearing Locknut.Spare Motor Operator Installed
ML20085G24716 October 1973Telecopy AO BFAO-7326T:on 731015,three of Eight Pressure Differential Switches Exceeded Tech Spec Limit
ML20085G26112 December 1974AO BFEAO-7422W:on 741202,water Temps in Wheeler Reservoir Not Recorded.Caused by Failure in Computer Controlling of Data Collection.Standby Computer Spare Memory Board Interchanged W/Existing Memory Board
ML20085G26315 October 1973AO BFAO-7325W:on 731005,inner Rupture Diaphragm of HPCI Sys Failed.Caused by Several Vacuum Cycles Inside Turbine Discharge Piping.Replacement Rupture Diaphragm Installed & Design Investigation Initiated
ML20085G2664 December 1974AO BFAO-50-260/7429W:on 741124,main Steam Relief Valve FCV-1-31 Failed to Reset Properly After Manually Opened. Caused by Excessive Pilot Valve Leakage.Valve Replaced. Installation Monitored
ML20085G2745 October 1973AO BFAO-7325T:on 731005,HPCI Sys Failed.Caused by Leaking Ruptured Diaphragm.Surveillance Test Initiated Immediately But RCIC Turbine Governor Failed.Rcic Governor Adjusted & Tested
ML20085G28125 October 1973AO BFAO-7324W:on 731015,stack Gas Sample Pump a Motor Failed.Caused by Overheating & Deterioration of Motor Insulation.Spare Motor Installed,Sample Sys Returned to Svc & Design Changes Re Motor Circuitry Proposed
ML20085G28419 October 1973AO BFAO-7323W:on 731011,vacuum Readings for Turbine Condenser Low Vacuum Switches PS-2-1A & PS-2-1D Exceeded Tech Spec Limit.Mechanisms of Switches Inspected,Switches Recalibr & Testing Frequency Increased
ML20085G28812 October 1973Telecopy AO BFAO-7323T:on 731011,vacuum Readings for Turbine Condenser Low Vacuum Switches PS-2-1A & PS-2-1D Exceeded Tech Spec Limit
ML20085G30119 October 1973AO BFAO-7322W:on 731009,reactor Water Level Switches L1S-3-203B & L1S-3-203C Exceeded Tech Spec Setpoint at Readings of 537.5 & 537.2 Inches,Respectively.Switches Recalibr & Frequency of Testing Increased to Every 2 Wks
ML20085G30917 October 1973AO BFAO-7321W:on 731007,drywell Pressure Switches PS-64-56B & PS-64-56C Exceeded Tech Spec Setpoint.Switch Mechanisms Inspected,Switches Recalibr & Frequency of Testing Increased to Once Every 2 Wks
ML20085G3248 October 1973Telecopy AO BFAO-7321T:on 731007,setpoints of 2.05 & 2.02 Psig for Drywell Pressure Switches PS-64-56B & PS-64-56C Exceeded Tech Spec Limit
ML20085G33215 October 1973AOs Bf EAO-7325 Through 7330 Re Fish Killed When Impinged on Intake Screens on 731005-13.Incidents Occurred While Washing Circulating Water Pump Traveling Screens.Tobulation of Fish Kill Estimates Submitted
ML20085G3366 October 1973Telecopy AO of Estimated Fish Impingement on 731005 & 06
ML20085G34312 October 1973AO BFAO-7320W:on 731003-04:control Rod Drive 54-27 & 26-55 in Fully Withdrawn Insequence Condition.Strainer for Rod 26-55 Cleaned,Violation of Tech Spec Assumed & Occurrence Being Reviewed
ML20085G3544 October 1973Telecopy AO BFAO-7320T:on 731003 & 04:control Rod Drives 54-27 & 26-5S in Fully Withdrawn Insequence Condition
ML20085G38910 October 1973AO BFAO-7319W:on 731001,reactor Water Cleanup Sys Valve PCV-69-12 Failed.Caused by Stripped Brass Worm Gear Teeth of SMB-00 Limitorque Operator.Operator Replaced & Frequency of Surveillance Increased to Monthly
ML20085G3922 October 1973Telecopy AO BFAO-7319T:on 731001,reactor Water Cleanup Sys Isolation Valve FVC-69-12 Failed.Caused by Problem W/Drive Gear Train.Isolation Valve Manually Closed & Investigation & Repair Continued
ML20085G4015 October 1973AOs Bf EAO-7319 Through 7324 Re Fish Killed When Impinged on Intake Screens on 730928-1004.Incidents Occurred During Washing of Circulating Water Pump Traveling Screens
ML20085G40613 December 1974AO BFAO-50-260/7431W:on 741203,HPCI Automatically Initiated Due to Low Reactor Water Level.Cause Not Determined. Corrective Actions Under Investigation
ML20085G4114 October 1973Telecopy AO BFEAO-7324T Re Fish Impingement on 731004
ML20085G41529 September 1973Telecopy AO BFEAO-7320:on 730929,fish Impingement of 3,000 Gizzard Shad & 270 Other Species Found
ML20085G4295 October 1973AO BFAO-7318W:on 730929,during Startup Testing,Hpci Invertor Power Supply Fuse Failed.Cause Under Investigation.Fuse Replaced
ML20085G43018 December 1974AO BFAO-50-260/7434W:on 741208,leak Indications Found on Main Steam Relief Valve Bellows 2-PCV-1-41 & 2-PCV-1-5. Caused by Shorted Cable Due to Melted Cable Insulation. Caused Repaired
ML20085G4355 October 1973AO BFAO-7317W:on 730927,RCIC Sys Flow Indicator FI-71-1A Indicated Negative Steamflow.Caused by Crossed High & Low Pressure Instrument Lines.Instrument Lines Reversed.All Lines Will Be Checked
ML20085G43823 August 1973AO BFAO-735W:on 730813,111.5 Psid Setpoint for Pressure Switch PdIS-1-36A of Main Steamline C High Flow Exceeded Tech Spec Limit of 108.75 Psid.Cause of Setpoint Drift Not Determined.Switch Reset
ML20085G4475 October 1973AO BFAO-7316W:on 730926,while Investigating Cause of Stack Gas Flow Abnormal Alarm,Stack Gas Monitor a Pump Motor Failed.Caused by Bad Motor Bearing Causing Motor Overload & Overheating.Motor & Fuse Replaced
ML20085G45128 September 1973AO BFAO-7315W:on 730920,93-psid Setting for Differential Pressure Switch Exceeded Tech Spec Limit.Caused by Switch Actuator Arm Offsetting.Arm Adjusted,Switch Recalibr & Monthly Testing Increased to Weekly
ML20085G46228 September 1973AO BFAO-7314W:on 730919,two Relief Valves Did Not Operate within Specified Limiting Settings.Administrative Procedures Will Be Strengthened & Temporary Tech Spec Rev Permitting Valve Operation at Improper Setting Initiated
ML20085G46414 August 1973Telecopy AO Bfnp AO 73T:111.5 Psid Setpoint of Pressure Switch PDIS-1-36A Exceeded Tech Spec Limit of 108.75 Psid. Switch Reset to Setpoint of 106.5 Psid
ML20085G52624 August 1973AO BFAO-736W:on 730816,level Switch LS-73-56B Exceeded Tech Spec Trip Level Setting.Caused by Sluggish Level Switch Spring Mechanism.Mechanism Adjusted & Level Switch Reset
ML20085G53517 August 1973Telecopy AO BFAO-736T:on 730816,level Switch LS-73-56B Exceeded Tech Spec Limit.Cause Being Investigated
ML20085G56717 August 1973AOs Bf EAO-732W Through 735W Re Shad Minnows & Other Fish Impinged on Intake Screens on 730809-14.Caused by Seasonal Concentrations of Young Shad & Incomplete Const of Intake Control Structure
ML20085G5838 September 1973Telecopy AO Bfeao 7312:on 730807,1200 Shad Fish Impinged
ML20085G5966 January 1975AO BFAO-50-259/7461W:on 741227,dampening Pins in Main Steam Line high-flow Pressure Switch Snubbers Installed W/O Proper Review & Authorization.Caused by Personnel Error. Procedures Revised
ML20085G6019 August 1973Telecopy AO BFAO-734T:on 730808,refueling Zone Vacuum Increased to Approx 0.8 Inch.Caused by Static Pressure Control Modulating Dampers Failure.Fuel Handling Operations Immediately Suspenede & Region II Notified
ML20085G6073 January 1975AO BFAO-50-259/7460W:on 741224,offgas Radiation Monitor Found Inoperable.Caused by Abnormal Leakage of Local Offgas Sample Flow Rotometer Due to Failure of O-ring to Seal properly.O-ring Reassembled